[Paper Review] Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit
This paper reports the most precise absolute frequency measurement of the 171Yb 1S₀→3P₀ optical transition to date—518,295,836,590,863.71(11) Hz with a fractional uncertainty of 2.1×10⁻¹⁶—enabling a loop closure test between Cs, Yb, and Sr clocks at the SI second's uncertainty limit. The measurement tightens constraints on time-variation of the electron-to-proton mass ratio to (5.3±6.5)×10⁻¹⁷/yr, representing a nearly two-fold improvement over prior limits.
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by comparing against a primary cesium reference. A key verification of this process can be achieved by performing a loop closure$-$comparing frequency ratios derived from absolute frequency measurements against ratios determined from direct optical comparisons. We measure the $^1$S$_0\! ightarrow^3$P$_0$ transition of $^{171}$Yb by comparing the clock frequency to an international frequency standard with the aid of a maser ensemble serving as a flywheel oscillator. Our measurements consist of 79 separate runs spanning eight months, and we determine the absolute frequency to be 518 295 836 590 863.71(11) Hz, the uncertainty of which is equivalent to a fractional frequency of $2.1 imes10^{-16}$. This absolute frequency measurement, the most accurate reported for any transition, allows us to close the Cs-Yb-Sr-Cs frequency measurement loop at an uncertainty of $
Motivation & Objective
- To achieve an absolute frequency measurement of the 171Yb 1S₀→3P₀ transition at the 10⁻¹⁶ level to support the redefinition of the SI second in terms of an optical transition.
- To verify consistency between absolute frequency measurements and direct optical comparisons by closing the Cs-Yb-Sr frequency measurement loop.
- To constrain possible temporal and gravitational variations of fundamental constants, particularly the electron-to-proton mass ratio μ.
- To improve the precision of time-variation limits for μ and the fine structure constant α using long-term data from multiple optical clocks.
Proposed method
- The absolute frequency of the 171Yb 1S₀→3P₀ transition was measured by comparing it to a primary cesium fountain clock using a maser ensemble as a flywheel oscillator.
- The measurement was performed over 79 runs spanning eight months, with systematic uncertainties reduced to 1.4×10⁻¹⁸, dominated by blackbody radiation and second-order Zeeman shifts.
- Frequency ratios were derived from both absolute measurements and direct optical comparisons, enabling a loop closure test at the level of the current SI second's uncertainty.
- Statistical and systematic uncertainties were propagated, including contributions from gravitational potential variations and possible time drifts in fundamental constants.
- The data from 7 Yb and 17 rescaled Sr absolute frequency measurements were fitted to a sinusoidal and linear model to extract constraints on μ variation.
- The analysis accounted for sensitivity of the Yb-Sr ratio to variations in α and μ, using known matrix elements and prior constraints on α and Xq.
Experimental results
Research questions
- RQ1Can the frequency ratio between Cs, Yb, and Sr optical clocks be measured with sufficient consistency to close the loop at the 10⁻¹⁶ uncertainty level?
- RQ2What is the most precise absolute frequency measurement of the 171Yb 1S₀→3P₀ transition to date?
- RQ3How do long-term optical clock measurements constrain the time-variation of the electron-to-proton mass ratio μ?
- RQ4To what extent do gravitational potential variations affect the measured frequency ratios, and how can they be accounted for in the analysis?
- RQ5Can the combined data from multiple optical clocks improve the constraint on the time-variation of μ beyond previous limits?
Key findings
- The absolute frequency of the 171Yb 1S₀→3P₀ transition was measured as 518,295,836,590,863.71(11) Hz with a fractional uncertainty of 2.1×10⁻¹⁶, the most precise reported for any atomic transition.
- The loop closure between Cs, Yb, and Sr frequency measurements was achieved at an uncertainty of less than 3×10⁻¹⁶, limited by the current realization of the SI second.
- The coupling coefficient of μ to gravitational potential was constrained to kμ = (-1.9±9.4)×10⁻⁷, indicating no significant variation within the uncertainty.
- The time-variation of μ was constrained to (5.3±6.5)×10⁻¹⁷/yr, representing a nearly two-fold improvement over the previous best limit of (-2±11)×10⁻¹⁷/yr.
- The analysis accounted for potential drifts in α and Xq, with conservative error propagation increasing the uncertainty on Sr measurements to 8.2×10⁻¹⁷, which had minimal impact on the overall result.
- The combined data from Yb and Sr clocks enabled a tighter constraint on μ variation than from the Yb measurement alone, reducing the uncertainty by a factor of 1.5.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.