This paper proposes a real-time, wearable-based shot detection system for racquet sports like table tennis by fusing audio and inertial measurement unit (IMU) data from a wrist-worn device. Using a novel Audio Peak Function (APF) and IMU Peak Function (IPF) with cross-correlation-based synchronization, the system achieves 95.6% F-score, significantly outperforming individual sensor approaches.
Wearables like smartwatches which are embedded with sensors and powerful processors, provide a strong platform for development of analytics solutions in sports domain. To analyze players' games, while motion sensor based shot detection has been extensively studied in sports like Tennis, Golf, Baseball; Table Tennis and Badminton are relatively less explored due to possible less intense hand motion during shots. In our paper, we propose a novel, computationally inexpensive and real-time system for shot detection in table tennis, based on fusion of Inertial Measurement Unit (IMU) and audio sensor data embedded in a wrist-worn wearable. The system builds upon our presented methodology for synchronizing IMU and audio sensor input in time using detected shots and achieves 95.6% accuracy. To our knowledge, it is the first fusion-based solution for sports analysis in wearables. Shot detectors for other racquet sports as well as further analytics to provide features like shot classification, rally analysis and recommendations, can easily be built over our proposed solution.
Motivation & Objective
- To develop a computationally efficient, real-time shot detection system for racquet sports using wrist-worn wearables.
- To address the challenge of low-intensity hand motion in sports like table tennis and badminton, which limits traditional IMU-based detection.
- To explore the fusion of audio and IMU data as a novel feature space for improved shot detection accuracy.
- To propose a synchronization method between audio and IMU signals using peak-based cross-correlation for temporal alignment.
- To establish a foundation for future analytics such as shot classification, rally analysis, and performance recommendations.
Proposed method
- The system uses a 10ms microframe and 100ms macroframe structure to compute Short Time Energy (STE) and derive the Audio Peak Function (APF) at 100Hz for shot likelihood estimation.
- The IMU Peak Function (IPF) is computed from accelerometer and gyroscope data at 100Hz, identifying local maxima in a 500ms neighborhood as shot candidates.
- A cross-correlation-based synchronization method aligns audio and IMU signals using peak functions, achieving a mean absolute error of 32ms with only 20 seconds of training data.
- A five-feature input set—APF, IPF, radial acceleration (a_rad), tangential acceleration (a_tan), and radial angular velocity (ω_rad)—is extracted around candidate shot points.
- A Random Forest classifier with 50 trees is trained on the synchronized, feature-rich data to classify each candidate as shot or non-shot.
- Consecutive shot detections are merged by retaining only the first peak to avoid overcounting.
Experimental results
Research questions
- RQ1Can audio and IMU sensor fusion improve shot detection accuracy in low-motion racquet sports like table tennis?
- RQ2How can audio and IMU signals be effectively synchronized in real-time wearable systems despite differing sampling rates and signal characteristics?
- RQ3Does the proposed Audio Peak Function (APF) with optimized filtering outperform traditional Energy Peak Detection (EPD) in shot detection?
- RQ4To what extent does combining IMU and audio features enhance detection performance compared to using either sensor alone?
- RQ5Can the proposed system be extended to support advanced analytics such as shot classification and rally analysis in wearable platforms?
Key findings
- The proposed system achieves a 95.6% F-score in shot detection, representing a 15% improvement over individual sensor-based methods.
- The APF-based audio detector with a 23-tap trained filter achieves an 80% F-score, outperforming the EPD-only method (42% F-score) and matching the performance of the EPD+MBR (C-SVC) method.
- The IMU-based detector using the IPF achieves a 78% F-score, outperforming the Srivastava [2] method, which achieved only 55% F-score on the same dataset.
- The synchronization method achieves a mean absolute error of 32ms using just 20 seconds of sensor data, enabling reliable alignment of audio and IMU streams.
- All five features (APF, IPF, a_rad, a_tan, ω_rad) show a correlation of over 0.4 with the shot class, validating their relevance for classification.
- The Random Forest classifier with 50 trees yields the highest F-score (95.6%) among tested models, outperforming SVM-RBF (91.5% F-score).