This paper presents X-ADC, a hardware prototype of the modulated wideband converter (MWC) that enables sub-Nyquist analog-to-digital conversion of wideband signals at rates far below the Nyquist rate. By mixing the input with multiple sinusoidal waveforms and using low-rate ADCs after lowpass filtering, the system achieves a sampling rate as low as 280 MHz for a 2 GHz Nyquist-rate signal with 120 MHz bandwidth occupancy, demonstrating accurate signal reconstruction and sub-Nyquist operation in real-world experiments.
We present a sub-Nyquist analog-to-digital converter of wideband inputs. Our circuit realizes the recently proposed modulated wideband converter, which is a flexible platform for sampling signals according to their actual bandwidth occupation. The theoretical work enables, for example, a sub-Nyquist wideband receiver, which has no prior information on the transmitter carrier positions. Our design supports input signals with 2 GHz Nyquist rate and 120 MHz spectrum occupancy, with arbitrary transmission frequencies. The sampling rate is as low as 280 MHz. To the best of our knowledge, this is the first reported wideband hardware for sub-Nyquist conversion. Furthermore, the modular design is proven to compete with state-of-the-art Nyquist ADCs in terms of resolution bits and full-scale range. We describe the various circuit design considerations, with an emphasis on the nonordinary challenges the converter introduces: mixing a signal with a multiple set of sinusoids, rather than a single local oscillator, and generation of highly-transient periodic waveforms, with transient intervals on the order of the Nyquist rate. A series of hardware experiments validates the design and demonstrate sub-Nyquist sampling.
Motivation & Objective
- To develop a practical, hardware-based implementation of the modulated wideband converter (MWC) for sub-Nyquist sampling of wideband signals.
- To address the challenge of sampling wideband signals with unknown carrier frequencies without prior knowledge of their positions.
- To demonstrate that sub-Nyquist sampling is feasible in real hardware with high dynamic range and resolution comparable to state-of-the-art Nyquist ADCs.
- To overcome circuit-level challenges such as mixing with multiple sinusoids and generating high-speed transient waveforms at the Nyquist rate.
- To validate the system with real-world wideband signals (AM, FM, PAM) and confirm accurate aliasing and signal reconstruction.
Proposed method
- The system uses a multi-band signal model where the input is composed of multiple narrowband transmissions with unknown carrier frequencies.
- The input signal is mixed with a periodic, highly transient waveform composed of multiple sinusoids at a fundamental frequency fp = 93.33 MHz.
- The mixing process aliases all spectrum slices into the baseband interval [-fp/2, fp/2], effectively folding the wideband signal into a lower-rate representation.
- Lowpass filtering is applied to extract the baseband components, followed by standard low-rate ADC sampling at 280 MHz.
- The system leverages the Xampling methodology, which enables analog compression prior to digitization, reducing the required sampling rate to near the theoretical minimum.
- Digital signal processing algorithms, previously developed in theory, are used to reconstruct the original signal from the sub-Nyquist samples.
Experimental results
Research questions
- RQ1Can a hardware prototype of the MWC be successfully implemented to achieve sub-Nyquist sampling of wideband signals?
- RQ2How can a signal be mixed with multiple sinusoidal waveforms simultaneously to achieve spectral folding at the analog level?
- RQ3What are the key circuit-level challenges in generating periodic waveforms with transient intervals on the order of the Nyquist rate?
- RQ4To what extent can the sub-Nyquist system maintain signal fidelity and dynamic range compared to state-of-the-art Nyquist ADCs?
- RQ5Can the system accurately reconstruct signals with unknown carrier frequencies across a wideband input (e.g., AM, FM, PAM) using only sub-Nyquist samples?
Key findings
- The X-ADC prototype successfully samples a 2 GHz Nyquist-rate input signal with 120 MHz spectrum occupancy at a rate as low as 280 MHz, achieving a 14% sampling rate relative to the Nyquist rate.
- The system demonstrates accurate signal reconstruction for AM, FM, and PAM signals, with aliasing frequencies matching theoretical predictions (e.g., 5.71 MHz, 4.82 MHz, 6.73 MHz) within 1% error.
- The measured signal-to-distortion ratio (SDR) was 36.2 dB, corresponding to an effective number of bits (ENOB) of 5.7, indicating good fidelity for the implemented resolution.
- The lowpass filter achieved 70 dB of stopband attenuation with smooth S21 and S11 responses, enabling clean baseband signal extraction.
- The dynamic range of input powers reached 50 dB, demonstrating robustness to varying signal amplitudes.
- The modular design of the X-ADC competes with state-of-the-art Nyquist ADCs in terms of resolution and full-scale range, validating its practical feasibility.