Kyushu University · Medicine
Professor Satoshi Hamai's research lab specializes in clinical and biomechanical investigations of knee joint function, with a focus on in vivo three-dimensional kinematics following total knee arthroplasty (TKA) and in osteoarthritic knees. The lab employs advanced imaging techniques such as continuous fluoroscopy and 3D-to-2D model registration to analyze dynamic joint motion, implant kinematics, and contact mechanics during daily and sports activities. Key research directions include understanding implant design effects—particularly posterior-stabilized versus cruciate-retaining TKA—on femoral rollback, tibiofemoral contact, and implant impingement during functional movements. The lab also investigates patient-reported outcomes and functional recovery in revision hip and knee arthroplasty, emphasizing real-world activity performance.
Figures are computed from collected data and may differ slightly.
Dynamic knee kinematics were analyzed for medial osteoarthritic (OA) knees in three activities, including two types of maximum knee flexion. Continuous x-ray images of kneeling, squatting, and stair climbing motions were taken using a large flat panel detector. CT-derived bone models were used for the model registration-based 3D kinematic measurements. Three-dimensional joint kinematics and contact locations were determined using two methods: bone-fixed coordinate systems and by interrogation of
Healthy knee kinematics during dynamic full flexion were evaluated using 3D-to-2D model registration techniques. Continuous knee motions were recorded during full flexion in a lunge from 85° to 150°. Medial and lateral tibiofemoral contacts and femoral internal-external and varus-valgus rotations were analyzed as a function of knee flexion angle. The medial tibiofemoral contact translated anteroposteriorly, but remained on the center of the medial compartment. On the other hand, the lateral tibi
Kneeling is an important function of the knee for many activities of daily living. In this study, we evaluated the in vivo kinematics of kneeling after total knee arthroplasty (TKA) using radiographic based image-matching techniques. Kneeling from 90 to 120 degrees of knee flexion produced a posterior femoral rollback after both cruciate-retaining and posterior-stabilized TKA. It could be assumed that the posterior cruciate ligament and the post-cam mechanism were functioning. The posterior-stab
Mechanical failure because of wear or fracture of the polyethylene tibial post in posteriorly-stabilised total knee replacements has been extensively described. In this study of 12 patients with a clinically and radiologically successful NexGen LPS posteriorly-stabilised prosthesis impingement of the anterior tibial post was evaluated in vivo in three dimensions during gait using radiologically-based image-matching techniques. Impingement was observed in all images of the patients during the sta
Revision THA was associated with a modest but significant decrease in physical PROMs as compared with primary THA. Pre-operative UCLA activity score significantly affected the post-operative physical outcome measures in the revision THA cohort. However, post-operative SF-12 MCS was comparable between the primary and revision THA cohorts.
The expectation of returning to sports activities after total knee arthroplasty (TKA) has become more important to patients than ever. To our knowledge, no studies have been published evaluating the three-dimensional knee joint kinematics during sports activity after TKA. Continuous X-ray images of the golf swing and stationary cycling were taken using a large flat panel detector for four and eight post-arthroplasty knees, respectively. The implant flexion and axial rotation angles were determin
In this case, the diagnosis was accurately confirmed, and the cervical spine was evaluated in detail using both 3-dimensional CT and MRI as a reliable examination for atlanto-occipital dislocation.
The static coronal laxity and alignment did not influence the lift-off under dynamic weight-bearing conditions after well-balanced and aligned cruciate-retaining TKA. Measured resection technique can produce sufficient coronal stability and alignment without significant lift-off during walking.
Open papers in the app to read, cite, and organize with AI.