一句话总结

Q_weak实验通过在1.16 GeV能量下对液态氢靶进行宇称破坏的电子散射,开发了一套专用装置以测量质子的弱电荷,实现了迄今最小的不对称性测量。利用89%极化的电子束流180 µA,以960 Hz的螺旋度反转频率运行,该装置在极端束流和探测器挑战下实现了前所未有的不对称性测量稳定性,达到亚ppb量级。

ABSTRACT

The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 microA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Moller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cerenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q^2 = 0.025 GeV^2 was determined using dedicated low-current (~100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.

研究动机与目标

  • 通过宇称破坏的弹性电子散射,以亚ppb精度测量质子的弱电荷。
  • 克服在实现高束流强度、高亮度以及最小化束流螺旋度相关参数引起的虚假不对称性方面的技术挑战。
  • 设计并运行一套专用实验装置,以探测电子散射中迄今最小的不对称性。
  • 将束流动力学、极化度和探测器响应带来的系统误差控制在1%以下。
  • 在严格束流和探测器条件下,验证长时间数据获取过程中不对称性测量的稳定性和一致性。

提出的方法

  • 采用1.16 GeV电子束流,纵向极化度为89%,以960 Hz频率反转螺旋度,以实现精确的不对称性测量。
  • 使用Møller和Compton极化度计,将束流极化度测量的不确定度控制在1%以内。
  • 采用34.4 cm长的液态氢靶,冷却至20 K,利用计算流体动力学设计,以承受数千瓦的束流功率。
  • 部署三重准直系统和一个由电阻性铜线圈构成的环形磁谱仪,将散射电子聚焦至5.8°–11.6°角区间,并进入八个熔融石英Čerenkov探测器。
  • 采用积分模式读出,配备专用低噪声前置放大器和18位采样ADC,以处理总散射电子速率高达7 GHz的信号。
  • 在环形磁铁前后进行专门的低束流(100 pA)漂移室测量,以高精度确定Q² = 0.025 GeV²。

实验结果

研究问题

  • RQ1能否通过宇称破坏的电子散射,以亚ppb精度测量质子的弱电荷?
  • RQ2如何控制并校正束流螺旋度相关参数,以避免在几亿分之一量级上产生虚假不对称性?
  • RQ3为在低温液态氢靶上持续承受180 µA极化电子束流而不发生热或机械失效,需要哪些设计创新?
  • RQ4在高流强、高亮度环境下,束流运动、极化度和探测器响应带来的系统误差能在多大程度上被量化和校正?
  • RQ5测量得到的不对称性在长时间尺度上是否保持稳定?独立的灵敏度标定方法是否一致?

主要发现

  • 该实验在宇称破坏电子散射(PVES)测量中实现了迄今记录的最小绝对精度,不对称性稳定性达到几亿分之一量级。
  • 测量得到的不对称性在多个螺旋度反转状态之间保持一致,并在数月的数据采集过程中表现出长期稳定性。
  • 两种独立方法——自然束流运动和受动束流调制——对螺旋度相关束流不对称性进行了校正,结果一致,校正量仅为几ppb。
  • 该装置成功在低温液态氢靶上以180 µA束流运行,由于靶的高功率沉积和热管理需求,这是一项技术里程碑。
  • 通过Møller和Compton极化度计,束流极化度测量的不确定度优于1%,确保了不对称性提取的高保真度。
  • 最终不对称性(在盲测且未校正极化度和背景前)未显示显著漂移或系统性偏差,证实了装置和方法的鲁棒性。