Dong Sung Kim
Pohang University of Science and Technology · Engineering
About the Lab
Professor Dong Sung Kim's research lab specializes in microfluidic systems, nanofabrication, and lab-on-a-chip technologies, with a strong focus on developing innovative microscale devices for biomedical applications. The lab pioneers advanced micromixer designs—such as serpentine laminating and barrier-embedded micromixers—to enhance mixing efficiency in low-Reynolds-number flows, enabling rapid and reliable biochemical reactions. It also develops low-cost, disposable microfluidic biochips for point-of-care diagnostics, including blood typing and particle engineering, while exploring novel fabrication techniques like thermal nanoimprinting for flexible and transparent energy devices. The lab integrates microfluidics with materials science to create multifunctional, cost-effective, and scalable solutions for healthcare and energy applications.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15Mixing enhancement has drawn great attention from designers of micromixers, since the flow in a microchannel is usually characterized by a low Reynolds number (Re) which makes the mixing quite a difficult task to accomplish. In this paper, a novel integrated efficient micromixer named serpentine laminating micromixer (SLM) has been designed, simulated, fabricated and fully characterized. In the SLM, a high level of efficient mixing can be achieved by combining two general chaotic mixing mechanis
Mixing enhancement has drawn a great attention to designing of micromixers, since the flow in a microchannel is usually characterized by a low Reynolds number (Re) which makes mixing quite a difficult task to complete. In this regard, we present a new chaotic passive micromixer, called a barrier embedded micromixer (BEM). In the BEM, chaotic flow is induced by periodic perturbation of the velocity field due to periodically inserted barriers along the top surface of the channel while a helical ty
Blood typing is the most important test for both transfusion recipients and blood donors. In this paper, a low cost disposable blood typing integrated microfluidic biochip has been designed, fabricated and characterized. In the biochip, flow splitting microchannels, chaotic micromixers, reaction microchambers and detection microfilters are fully integrated. The loaded sample blood can be divided by 2 or 4 equal volumes through the flow splitting microchannel so that one can perform 2 or 4 blood
Complex microparticles (MPs) bearing unique characteristics such as well-tailored sizes, various morphologies, and multi-compartments have been attempted to be produced by many researchers in the past decades. However, a conventionally used method of fabricating MPs, emulsion polymerization, has a limitation in achieving the aforementioned characteristics and several approaches such as the microfluidics-assisted (droplet-based microfluidics and flow lithography-based microfluidics), electrohydro
Understanding filling flow into micro-channels is important in designing micro-injection molding, micro-fluidic devices and an MIMIC (micromolding in capillaries) process. In this paper, we investigated, both experimentally and numerically, 'transient filling' flow into micro-channels, which differs from steady-state completely 'filled' flow in micro-channels. An experimental flow visualization system was devised to facilitate observation of flow characteristi
Using thermal nanoimprinting, a novel transparent and flexible nanotopographical triboelectric nanogenerator (TENG), with simultaneous nanoreplication and integration of the contact layer with the electrode layer, is first demonstrated. It is expected that the present rapid one-step fabrication methodology well give "disposability" to the TENG with extremely reduced manufacturing costs, which may allay commercialization concerns.
The triboelectric series is a generally accepted method for describing the triboelectric effect. It provides a way to control the double face of the ubiquitous triboelectric effect: causes of unpredictable accidents and the resultant surface charge as energy sources. However, previous studies have been biased in solids despite being observed in liquids (liquid-solid contact electrification). Therefore, a liquid triboelectric series is necessary to be established to manipulate the liquid triboele
A free-standing nanofiber membrane can be simultaneously fabricated, patterned, and integrated with electrolyte-assisted electrospinning (ELES). The fluidic nature of the electrolyte collector enables flexible patterning and facile integration of the free-standing nanofiber membrane on complex substrates from a 2D flat surface to a 3D curved geometry via ELES. The structural integrity and performance of the free-standing nanofiber membrane are verified, and this plays a crucial role for future a
It is of great interest to enhance the mixing performance in a microchannel in which the flow is usually characterized by a low Reynolds number (Re) so that good mixing is quite difficult to achieve. In this regard, we present a new chaotic passive micromixer, named the barrier embedded Kenics micromixer (BEKM). In the BEKM, a higher level of chaotic mixing can be achieved by combining two general chaotic mixing mechanisms: splitting/reorientation and stretching/folding. The splitting/reorientat
Herein, a collagen gel-coated and aligned nanofiber membrane named Col-ANM is developed, which remarkably improves endothelial barrier function by providing biochemical and topographical cues simultaneously. Col-ANM is fabricated by collagen gel coating process on an aligned polycaprolactone (PCL) nanofiber membrane, which is obtained by a simple electrospinning process adopting a parallel electrode collector. Human umbilical vein endothelial cells (HUVECs) cultured on Col-ANM exhibit remarkably
Research Areas
Dive deeper into Dong Sung Kim's research on Nubint
Open this lab's papers in the app to read with AI, summarize, and cite in your writing.