Skip to main content

Hunyeop Kim

Korea University · Medicine

About the Lab

Professor Hunyeop Kim's research lab specializes in advanced minimally invasive and robotic surgical techniques, with a primary focus on transoral and transaxillary robotic thyroidectomy for thyroid cancer. The lab investigates surgical outcomes, neuromonitoring during endotracheal intubation, and comparative effectiveness between robotic and conventional laparoscopic approaches in endocrine surgery. Research also extends to optimizing surgical instrumentation and patient safety through real-time neuromonitoring and technical refinement.

robotic thyroidectomytransoral surgeryneuromonitoringminimally invasive surgeryadrenalectomy

Research Overview

Papers
234
Total Citations
5,293
Papers (5y)
26
Primary Field
Medicine

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
26total
2022
2023
2024
2025
2026
Citations per year (5y)
94total
20222023202420252026

Selected Papers

15
1
Article|162 citations·2017
Transoral robotic thyroidectomy: lessons learned from an initial consecutive series of 24 patients
Hoon Yub Kim, Young Jun Chai, Gianlorenzo Dionigi, Angkoon Anuwong, Jeremy D. Richmon
SJR Q1Surgical Endoscopy
SurgeryMedicine
2
Article|104 citations·2017
Transoral endoscopic thyroidectomy via a vestibular approach: why and how?
Gianlorenzo Dionigi, Young Jun Chai, Ralph P. Tufano, Angkoon Anuwong, Hoon Yub Kim
SJR Q2Endocrine
SurgeryMedicine
3
Article|74 citations·2018
Transoral Robotic Thyroidectomy for Papillary Thyroid Carcinoma: Perioperative Outcomes of 100 Consecutive Patients
Hong Kyu Kim, Young Jun Chai, Gianlorenzo Dionigi, Eren Berber, Ralph P. Tufano, Hoon Yub Kim, Hoon Yub Kim, Hoon Yub Kim
SJR Q1World Journal of Surgery

BACKGROUND: Endoscopic transoral thyroidectomy is a recently introduced technique of remote access thyroidectomy. We previously reported the feasibility of the robotic approach (TORT). Nevertheless, experience to date is limited, with scant data on outcomes in patients with papillary thyroid carcinoma (PTC). METHODS: This was a retrospective analysis of prospectively collected data. Patients with PTC, who underwent TORT at a single center between March 2016 and February 2017, were analyzed. RESU

SurgeryMedicine
4
Article|69 citations·2017
Comparative analysis of 2 robotic thyroidectomy procedures: Transoral versus bilateral axillo‐breast approach
Young Jun Chai, Hoon Yub Kim, Hoon Yub Kim, Hong Kyu Kim, Hong Kyu Kim, Sang-Ho Jun, Gianlorenzo Dionigi, Angkoon Anuwong, Jeremy D. Richmon, Ralph P. Tufano
SJR Q1Head & NeckOA

BACKGROUND: The surgical outcomes of a single surgeon's initial cases of transoral robotic thyroidectomy (TORT) were compared with the surgeon's initial cases of a bilateral axillo-breast approach (BABA) robotic thyroidectomy. METHODS: The medical reports were retrospectively reviewed. The BABA robotic thyroidectomies were performed between 2008 and 2009, and TORTs were performed between 2012 and 2016. RESULTS: Each group comprised 50 patients. Operative time for total thyroidectomy was shorter,

SurgeryMedicine
5
Article|57 citations·2015
Impact of positional changes in neural monitoring endotracheal tube on amplitude and latency of electromyographic response in monitored thyroid surgery: Results from the Porcine Experiment
Hoon Yub Kim, Ralph P. Tufano, Gregory W. Randolph, Marcin Barczyński, Che‐Wei Wu, Feng‐Yu Chiang, Xiaoli Liu, Hiroo Masuoka, Akira Miyauchi, Soo Young Park, Hee Yong Kwak, Hye Yoon Lee
SJR Q1Head & NeckOA

BACKGROUND: The purpose of this study was to evaluate electromyography (EMG) amplitude and latency changes during tube dislocation in monitored thyroid surgery, which may be observed without recurrent laryngeal nerve injury. METHODS: Duroc-Landrace piglets were intubated with the TriVantage EMG tube. We measured EMG changes during both upward and downward tube dislocation (10-20 mm) and rotation (45-90°) with continuous neuromonitoring. RESULTS: The EMG amplitude varied significantly with induce

SurgeryMedicine
6
Review|52 citations·2017
Neuromonitoring in endoscopic and robotic thyroidectomy
Gianlorenzo Dionigi, Hoon Yub Kim, Che‐Wei Wu, Matteo Lavazza, Gabriele Materazzi, Celestino Pio Lombardi, Angkoon Anuwong, Ralph P. Tufano
SJR Q1Updates in Surgery
SurgeryMedicine
7
Article|52 citations·2015
Recurrent laryngeal nerve safety parameters of the Harmonic Focus during thyroid surgery: Porcine model using continuous monitoring
Che‐Wei Wu, Young Jun Chai, Gianlorenzo Dionigi, Feng‐Yu Chiang, Xiaoli Liu, Hui Sun, Gregory W. Randolph, Ralph P. Tufano, Hoon Yub Kim
SJR Q1The Laryngoscope

NA.

SurgeryMedicine
8
Article|52 citations·2015
Thermal injury of the recurrent laryngeal nerve by THUNDERBEAT during thyroid surgery: findings from continuous intraoperative neuromonitoring in a porcine model
Hee Yong Kwak, Gianlorenzo Dionigi, Dasom Kim, Hye Yoon Lee, Gil Soo Son, Jae Bok Lee, Jeoung Won Bae, Hoon Yub Kim
SJR Q1Journal of Surgical Research
SurgeryMedicine
9
Article|48 citations·2013
Comparison of robotic adrenalectomy with traditional laparoscopic adrenalectomy with a lateral transperitoneal approach: a single‐surgeon experience
Ji Young You, Hye Yoon Lee, Gil Soo Son, Jae Bok Lee, Jeoung Won Bae, Hoon Yub Kim
SJR Q2International Journal of Medical Robotics and Computer Assisted Surgery

BACKGROUND: Although several recent studies have demonstrated the feasibility and safety of robotic adrenalectomy, it is unknown whether this procedure has advantages over the traditional laparoscopic approach. This study compared our initial experience using the da Vinci-S® robotic surgical system during laparoscopic adrenalectomy with our experience with traditional laparoscopic adrenalectomy. METHODS: From October 2009 to May 2012, 23 consecutive patients (13 women, 10 men) underwent laparosc

SurgeryMedicine
10
Article|46 citations·2019
Transoral Robotic Thyroidectomy Versus Conventional Open Thyroidectomy: Comparative Analysis of Surgical Outcomes in Thyroid Malignancies
Ji Young You, Hoon Yub Kim, Hoon Yub Kim, Young Jun Chai, Hong Kyu Kim, Hong Kyu Kim, Angkoon Anuwong, Ralph P. Tufano, Gianlorenzo Dionigi
SJR Q2Journal of Laparoendoscopic & Advanced Surgical Techniques

Abstract Background: Various approaches for thyroid surgery became possible with the use of robotic systems. Transoral robotic thyroidectomy (TORT) is one of the newest approaches and draws attention because of its cosmetic excellence. In this study, we compared the surgical outcomes of TORT and conventional open thyroidectomy (OT). Methods: We retrospectively reviewed and compared the medical records of consecutive patients who underwent TORT or OT for thyroid carcinoma from April 2016 to March

SurgeryMedicine
11
Article|46 citations·2014
Robotic thyroidectomy using bilateral axillo-breast approach: Comparison of surgical results with open conventional thyroidectomy
Hee Yong Kwak, Hoon Yub Kim, Hye Yoon Lee, Seung Pil Jung, Sang Uk Woo, Gil Soo Son, Jae Bok Lee, Jeoung Won Bae
SJR Q1Journal of Surgical Oncology

Robotic thyroidectomy using BABA may be a technically feasible and safe procedure comparable to conventional open surgery especially in node-negative patients.

SurgeryMedicine
12
Article|41 citations·2015
Robotic Transoral Periosteal Thyroidectomy (TOPOT): Experience in Two Cadavers
Hye Yoon Lee, Jeremy D. Richmon, Rohan R. Walvekar, F. Christopher Holsinger, Hoon Yub Kim
SJR Q2Journal of Laparoendoscopic & Advanced Surgical Techniques

Robotic transoral periosteal thyroidectomy provides superior access to the thyroid and central neck compartment. Transoral thyroidectomy using four ports is a feasible and safe method.

SurgeryMedicine
13
Article|40 citations·2015
Prospective validation study of Cernea classification for predicting EMG alterations of the external branch of the superior laryngeal nerve
Gianlorenzo Dionigi, Hoon Yub Kim, Gregory W. Randolph, Che‐Wei Wu, Hui Sun, Xiaoli Liu, Marcin Barczyński, Feng‐Yu Chiang
SJR Q2Surgery TodayOA
SurgeryMedicine
14
Article|40 citations·2020
Transoral robotic thyroidectomy versus conventional open thyroidectomy: comparative analysis of surgical outcomes using propensity score matching
Ji Young You, Hoon Yub Kim, Da Won Park, Hsien Wen Yang, Hong Kyu Kim, Gianlorenzo Dionigi, Ralph P. Tufano, Gianlorenzo Dionigi, Ralph P. Tufano
SJR Q1Surgical Endoscopy
SurgeryMedicine
15
Article|36 citations·2015
Continuous intraoperative neuromonitoring in thyroid surgery: Safety analysis of 400 consecutive electrode probe placements with standardized procedures
Alberto Mangano, Hoon Yub Kim, Che‐Wei Wu, Stefano Rausei, Hui Sun, Liu Xiaoli, Feng‐Yu Chiang, Dimitrios H Roukos, Georgios D. Lianos, Erivelto Volpi, Gianlorenzo Dionigi
SJR Q1Head & Neck

BACKGROUND: Continuous intraoperative neuromonitoring (C-IONM) is a new technology and it is appropriate to analyze its safety. METHODS: C-IONM was performed according to a standardized technique to control any adverse events and electrode positioning issues. RESULTS: Four hundred vagal nerve dissections were analyzed considering vagal nerve diameter, mean time effort for C-IONM probe positioning, and electrode dislocation rate. A significant superior dislocation rate in case of: (a) when a 3 mm

SurgeryMedicine

Research Areas

SurgeryEndocrinology, Diabetes and MetabolismNephrologyEpidemiologyAerospace EngineeringPathology and Forensic Medicine

Dive deeper into Hunyeop Kim's research on Nubint

Open this lab's papers in the app to read with AI, summarize, and cite in your writing.