Skip to main content

Hyun-Ho Jeong

Yonsei University · Medicine

About the Lab

Professor Hyun-Ho Jeong's research lab specializes in the development of advanced, biocompatible neural interface systems and neuromodulation technologies for treating neurological and psychiatric disorders. The lab focuses on creating soft, flexible, and implantable electronic devices—such as liquid metal-based electrodes and laser-patterned graphene bioelectrodes—that mimic the mechanical properties of brain tissue to minimize damage and enable long-term stability. Key research directions include stereotactic neurosurgery for treatment-resistant conditions like obsessive-compulsive disorder and essential tremor, as well as innovative applications of MRI-guided focused ultrasound and topical therapies for ocular and autoimmune-related disorders. The lab integrates materials science, biomedical engineering, and clinical neuroscience to pioneer next-generation implantable neuromodulation systems with high biocompatibility and functional precision.

neural interfacessoft electronicsneuromodulationbiocompatible materialsfocused ultrasound

Research Overview

Papers
197
Total Citations
3,237
Papers (5y)
60
Primary Field
Medicine

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
60total
2021
2022
2023
2024
2025
Citations per year (5y)
678total
20212022202320242025

Selected Papers

15
1
Article|180 citations·2014
Bilateral thermal capsulotomy with MR-guided focused ultrasound for patients with treatment-refractory obsessive-compulsive disorder: a proof-of-concept study
Hyun Ho Jung, Se Joo Kim, Daeyoung Roh, Jan‐Gowth Chang, Won Seok Chang, Eun Jung Kweon, Chang‐Hoon Kim, Jin Woo Chang, Jin Woo Chang, Jin Woo Chang
SJR Q1Molecular PsychiatryOA
Clinical PsychologyPsychology
2
Article|139 citations·2006
Bilateral Anterior Cingulotomy for Refractory Obsessive-Compulsive Disorder: Long-Term Follow-Up Results
Hyun Ho Jung, Chan‐Hyung Kim, Jong Hee Chang, Yong Gou Park, Sang Sup Chung, Jin Woo Chang
SJR Q1Stereotactic and Functional NeurosurgeryOA

OBJECTIVE: To investigate the long-term efficacy and adverse cognitive effects of stereotactic bilateral anterior cingulotomy as a treatment for refractory obsessive-compulsive disorder (OCD) patients. MATERIALS AND METHODS: Seventeen patients suffering from refractory OCD underwent stereotactic bilateral anterior cingulotomies and were followed for 24 months. The Yale-Brown Obsessive-Compulsive Scale (Y-BOCS), the Clinical Global Impression and other neuropsychological tests were used to assess

Clinical PsychologyPsychology
3
Article|73 citations·2014
Different magnetic resonance imaging patterns after transcranial magnetic resonance–guided focused ultrasound of the ventral intermediate nucleus of the thalamus and anterior limb of the internal capsule in patients with essential tremor or obsessive-compulsive disorder
Hyun Ho Jung, Won Seok Chang, Itay Rachmilevitch, Tal Tlusty, Eyal Zadicario, Jin Woo Chang
SJR Q1Journal of neurosurgeryOA

OBJECT: The authors report different MRI patterns in patients with essential tremor (ET) or obsessive-compulsive disorder (OCD) after transcranial MR-guided focused ultrasound (MRgFUS) and discuss possible causes of occasional MRgFUS failure. METHODS: Between March 2012 and August 2013, MRgFUS was used to perform unilateral thalamotomy in 11 ET patients and bilateral anterior limb capsulotomy in 6 OCD patients; in all patients symptoms were refractory to drug therapy. Sequential MR images were o

NeurologyMedicine
4
Article|53 citations·2024
In-vivo integration of soft neural probes through high-resolution printing of liquid electronics on the cranium
Young‐Geun Park, Yong Won Kwon, Chin Su Koh, Enji Kim, Dong Ha Lee, Sumin Kim, Jongmin Mun, Yeon‐Mi Hong, Sanghoon Lee, Ju‐Young Kim, Jae‐Hyun Lee, Hyun Ho Jung
SJR Q1Nature CommunicationsOA

Current soft neural probes are still operated by bulky, rigid electronics mounted to a body, which deteriorate the integrity of the device to biological systems and restrict the free behavior of a subject. We report a soft, conformable neural interface system that can monitor the single-unit activities of neurons with long-term stability. The system implements soft neural probes in the brain, and their subsidiary electronics which are directly printed on the cranial surface. The high-resolution

Cellular and Molecular NeuroscienceNeuroscience
5
Article|44 citations·2015
Long-Term Outcome of Treatment with Topical Corticosteroids for Severe Dry Eye Associated with Sjögren's Syndrome
Hyun Ho Jung, Yong Sok Ji, Mi Sun Sung, Kyung Keun Kim, Kyung Chul Yoon
Chonnam Medical JournalOA

This retrospective study was performed to analyze the long-term outcome of topical corticosteroid treatment for severe dry eye associated with Sjögren's syndrome (SS). Patients who had severe dry eye associated with SS were topically treated with loteprednol etabonate 0.5% (group A, n=66) or fluorometholone 0.1% (group B, n=67) twice daily and were followed up for 2 years. Visual acuity (VA), intraocular pressure (IOP), Schirmer test, tear film breakup time (BUT), keratoepitheliopathy, and sympt

Public Health, Environmental and Occupational HealthMedicine
6
Article|30 citations·2010
Structure and Orientation of a Voltage-Sensor Toxin in Lipid Membranes
Hyun Ho Jung, Hoi Jong Jung, Mirela Milescu, Chul Won Lee, Seungkyu Lee, Ju Yeon Lee, Young-Jae Eu, Ha Hyung Kim, Kenton J. Swartz, Jae Il Kim
SJR Q1Biophysical JournalOA
Molecular BiologyBiochemistry, Genetics and Molecular Biology
7
Article|25 citations·2023
Laser‐Assisted Structuring of Graphene Films with Biocompatible Liquid Crystal Polymer for Skin/Brain‐Interfaced Electrodes
Rowoon Park, Dong Hyeon Lee, Chin Su Koh, Young Woo Kwon, Seon Yeong Chae, Chang‐Seok Kim, Hyun Ho Jung, Joonsoo Jeong, Suck Won Hong
SJR Q1Advanced Healthcare MaterialsOA

The work presented here introduces a facile strategy for the development of flexible and stretchable electrodes that harness the robust characteristics of carbon nanomaterials through laser processing techniques on a liquid crystal polymer (LCP) film. By utilizing LCP film as a biocompatible electronic substrate, control is demonstrated over the laser irradiation parameters to achieve efficient pattern generation and transfer printing processes, thereby yielding highly conductive laser-induced g

Biomedical EngineeringEngineering
8
Article|24 citations·2025
Implantable Soft Neural Electrodes of Liquid Metals for Deep Brain Stimulation
Yong Won Kwon, Enji Kim, Chin Su Koh, Young‐Geun Park, Yeon‐Mi Hong, Sanghoon Lee, Jakyoung Lee, Tae Jun Kim, Wonki Mun, Seung Hyun Min, Sumin Kim, Jung Ah Lim
SJR Q1ACS Nano

Stimulating large volumes of neural networks using macroelectrodes can modulate disorder-associated brain circuits effectively. However, conventional solid-metal electrodes often cause unwanted brain damage due to their high mechanical stiffness. In contrast, low-modulus liquid metals provide tissue-like stiffness while maintaining macroscale electrode dimensions. Here, we present implantable soft macroelectrodes made from biocompatible liquid metals for brain stimulation. These probes can be ea

Cellular and Molecular NeuroscienceNeuroscience
9
Article|24 citations·2016
Rostral Agranular Insular Cortex Lesion with Motor Cortex Stimulation Enhances Pain Modulation Effect on Neuropathic Pain Model
Hyun Ho Jung, Jaewoo Shin, Jin-Hyung Kim, Seung-Hee Ahn, Sung‐Eun Lee, Chin Su Koh, Jae Sung Cho, Chanho Kong, Hyung-Cheul Shin, Sung June Kim, Jin Woo Chang
SJR Q2Neural PlasticityOA

It is well known that the insular cortex is involved in the processing of painful input. The aim of this study was to evaluate the pain modulation role of the insular cortex during motor cortex stimulation (MCS). After inducing neuropathic pain (NP) rat models by the spared nerve injury method, we made a lesion on the rostral agranular insular cortex (RAIC) unilaterally and compared behaviorally determined pain threshold and latency in 2 groups: Group A (NP + MCS;<mml:math xmlns:mml="http://www.

PhysiologyMedicine
10
Article|24 citations·2004
Isolation and characterization of a neutralizing antibody specific to internalization domain of Clostridium botulinum neurotoxin type B
Gi‐Hyeok Yang, Kyu-Sik Kim, Hak-Woo Kim, Sung Tae Jeong, Gyung Heng Huh, Ji Cheon Kim, Hyun Ho Jung
SJR Q3Toxicon
NeurologyMedicine
11
Article|22 citations·2010
Gamma Knife surgery for low-flow cavernous sinus dural arteriovenous fistulas
Hyun Ho Jung, Jong Hee Chang, Kum Whang, Jin Soo Pyen, Jin Woo Chang, Yong Gou Park
SJR Q1Journal of neurosurgeryOA

OBJECT: The purpose of this study was to assess the efficacy of Gamma Knife surgery (GKS) for treating cavernous sinus dural arteriovenous fistulas (CSDAVFs). METHODS: Of the 4123 GKSs performed between May 1992 and March 2009, 890 procedures were undertaken to treat vascular lesions. In 24 cases, the vascular lesion that was treated was a dural arteriovenous fistula, and in 6 of these cases, the lesion involved the cavernous sinus. One of these 6 cases was lost to follow-up, leaving the other 5

NeurologyMedicine
12
Article|19 citations·2024
Interference haptic stimulation and consistent quantitative tactility in transparent electrotactile screen with pressure-sensitive transistors
Kyeonghee Lim, Jakyoung Lee, Sumin Kim, Myoungjae Oh, Chin Su Koh, Hunkyu Seo, Yeon‐Mi Hong, Won Gi Chung, Jiuk Jang, Jung Ah Lim, Hyun Ho Jung, Jang‐Ung Park
SJR Q1Nature CommunicationsOA

Integrating tactile feedback through haptic interfaces enhances experiences in virtual and augmented reality. However, electrotactile systems, which stimulate mechanoreceptors directly, often yield inconsistent tactile results due to variations in pressure between the device and the finger. In this study, we present the integration of a transparent electrotactile screen with pressure-sensitive transistors, ensuring highly consistent quantitative haptic sensations. These transistors effectively c

Cognitive NeuroscienceNeuroscience
13
Article|17 citations·2019
Gamma Knife Radiosurgery for Postoperative Remnant Meningioma: Analysis of Recurrence Factors According to World Health Organization Grade
Chang Kyu Park, Na Young Jung, Won Seok Chang, Hyun Ho Jung, Jin Woo Chang
SJR Q2World NeurosurgeryOA
EpidemiologyMedicine
14
Article|15 citations·2014
Higher Order Aberrations of the Corneal Surface after Laser Subepithelial Keratomileusis
Hyun Ho Jung, Yong Sok Ji, Han Jin Oh, Kyung Chul Yoon
SJR Q2Korean Journal of OphthalmologyOA

The HOAs including coma, trefoil and SA significantly increased after LASEK. The tear film instability in the dry eye can be associated with more deterioration of the optical quality after LASEK, due to more significant increase of total HOA RMS, coma and trefoil.

Public Health, Environmental and Occupational HealthMedicine
15
Article|14 citations·2015
Clinical Efficacy of Topical 3% Diquafosol Tetrasodium in Short Tear Film Break-Up Time Dry Eye
Hyun Ho Jung, Yeon Soo Kang, Mi Sun Sung, Kyung Chul Yoon
SJR Q4Journal of the Korean Ophthalmological Society
Public Health, Environmental and Occupational HealthMedicine

Research Areas

NeurologyPhysiologyClinical PsychologyPathology and Forensic MedicineCellular and Molecular NeuroscienceBiomedical Engineering

Dive deeper into Hyun-Ho Jeong's research on Nubint

Open this lab's papers in the app to read with AI, summarize, and cite in your writing.