Skip to main content

Jae Hyeung Park

Seoul National University

About the Lab

Professor Jae Hyeung Park's research lab specializes in interventional radiology and diagnostic medical imaging, with a strong focus on vascular interventions and advanced medical imaging techniques. The lab investigates image-guided embolization therapies for critical conditions such as nonvariceal upper GI bleeding and hepatocellular carcinoma, emphasizing the use of embolic agents like NBCA and chemoembolization. It also explores the application of multi-detector row CT and dual-source CT in coronary imaging, vascular anatomy assessment in living donors, and the evaluation of vascular diseases such as Takayasu arteritis. The lab is committed to improving diagnostic accuracy, optimizing radiation dose, and advancing interventional radiology through high-resolution imaging and clinical correlation.

interventional radiologyvascular embolizationcoronary CT angiographymedical imagingvascular anatomy

Research Overview

Papers
63
Total Citations
374
Papers (5y)
5
Primary Field

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
5total
2013
2014
2018
2019
2026
Citations per year (5y)
2total
20132014201820192026

Selected Papers

15
1
Article|58 citations·2007
Transcatheter Arterial Embolization of Nonvariceal Upper Gastrointestinal Bleeding with N-Butyl Cyanoacrylate
제환준, 정진욱, 정아영, 이활, 박재형

Objective: To evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with N-Butyl Cyanoacrylate (NBCA) for nonvariceal upper gastrointestinal bleeding. Materials and Methods: Between March 1999 and December 2002, TAE for nonvariceal upper gastrointestinal bleeding was performed in 93 patients. The endoscopic approach had failed or was discarded as an approach for control of bleeding in all study patients. Among the 93 patients NBCA was used as the primary embolic

2
Article|54 citations·2006
Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Prevalence and Causative Factors of Extrahepatic Collateral Arteries in 479 Patients
정진욱, 김효철, 윤정환, Hyo-Suk Lee, 제환준, 이활, 박재형

Objective: We wanted to investigate the prevalence and causative factors of extrahepatic arterial blood supply to hepatocellular carcinoma (HCC) at its initial presentation and during chemoembolization. Materials and Methods: Between February 1998 and April 2000, consecutive 479 patients with newly diagnosed HCC were prospectively enrolled into this study. A total of 1629 sessions of transcatheter arterial chemoembolization (TACE) were performed in these patients (range: 1 15 sessions; mean: 3.4

3
Article|36 citations·2009
The Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography
박은아, 강진화, 인용후, 정진욱, 박재형, 이활

Objective: This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. Materials and Methods: We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effective mAs or 120 kVp and 500 effective mAs. The density measurements (image noise, vessel density, sign

4
Article|22 citations·2007
Follow-up CT Evaluation of the Mural Changes in Active Takayasu Arteritis
제환준, 박재형, 정진욱, 김효철, 이활, 소영호, 김상영

Objective: We wanted to evaluate the mural changes by CT on the follow-up examination of patients with active Takayasu arteritis. Materials and Methods: The study included 18 patients, (4 males and 14 females), with active Takayasu arteritis. A total of 44 CT examinations were done during the follow-up period (mean: 55.6 months). At the time of the last follow-up CT, the disease, on the basis of the erythrocyte sedimentation rate (ESR), was found to be inactive in five patients and the disease w

5
Article|22 citations·2008
CT Angiography for Living Kidney Donors: Accuracy, Cause of Misinterpretation and Prevalence of Variation
채지원, 이활, Yong Hu Yin, 제환준, 정진욱, Hyeon Hoe Kim, 박재형

Objective: To determine the accuracy of the use of multi-detector row CT (MDCT) to predict vascular anatomy in living kidney donors and to reveal the prevalence of vascular variations in a Korean population. Materials and Methods: A total of 153 living kidney donors that had undergone preoperative CT and nephrectomy, either with open or laparoscopic surgery, were selected retrospectively. The initial CT results were compared with the surgical findings and repeated review sessions of CT scans wer

6
Article|17 citations·2012
Ultrasound and Fluoroscopy-Guided Placement of Central Venous Ports via Internal Jugular Vein: Retrospective Analysis of 1254 Port Implantations at a Single Center
안세진, 김효철, 정진욱, 안상부, 인용후, 제환준, 박재형

Objective: To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. Materials and Methods: We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the i

7
Article|17 citations·2011
The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution’s Experience
문준호, 박은아, 이활, Yong Hu Yin, 정진욱, 박재형, 이해영, 강현재, 김효수

Objective: We wanted to evaluate the image quality, diagnostic accuracy and radiation exposure of 64-slice dual-source CT (DSCT) coronary angiography according to the heart rate in symptomatic patients during daily clinical practice. Materials and Methods: We performed a retrospective search for the DSCT coronary angiography reports of 729 consecutive symptomatic patients. For the 131 patients who underwent invasive coronary angiography, the image quality, the diagnostic performance (sensitivity

8
Article|16 citations·2007
FDG-PET for Evaluating the Antitumor Effect of Intraarterial 3-Bromopyruvate Administration in a Rabbit VX2 Liver Tumor Model
박희선, 정진욱, 제환준, 김영일, 손규리, 이민종, 박재형, 강원준, 윤정환, 정혜선, 이기창

Objective: We wanted to investigate the feasibility of using FDG-PET for evaluating the antitumor effect of intraarterial administration of a hexokinase II inhibitor, 3-bromopyruvate (3-BrPA), in a rabbit VX2 liver tumor model. Materials and Methods: VX2 carcinoma was grown in the livers of ten rabbits. Two weeks later, liver CT was performed to confirm appropriate tumor growth for the experiment. After tumor volume-matched grouping of the rabbits, transcatheter intraarterial administration of 3

9
Article|16 citations·2009
The Antitumor Effect and Hepatotoxicity of a Hexokinase II Inhibitor 3-Bromopyruvate: In Vivo Investigation of Intraarterial Administration in a Rabbit VX2 Hepatoma Model
제환준, 정진욱, 이민종, 김효철, 윤정환, 정혜선, 박재형, 이기창, 박희선

Objective: The purpose of this study was to compare the antitumor effect and hepatotoxicity of an intraarterial delivery of low-dose and high-dose 3-bromopyruvate (3-BrPA) and those of a conventional Lipiodol-doxorubicin emulsion in a rabbit VX2 hepatoma model. Materials and Methods: This experiment was approved by the animal care committee at our institution. VX2 carcinoma was implanted in the livers of 36 rabbits. Transcatheter intraarterial administration was performed using low dose 3- BrPA

10
Article|15 citations·2009
Transcatheter Arterial Embolization of Arterial Esophageal Bleeding with the Use of N-Butyl Cyanoacrylate
박지훈, 김효철, 정진욱, 제환준, 박재형

Objective: To evaluate the clinical efficacy and safety of a transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) for the treatment of arterial esophageal bleeding. Materials and Methods: Between August 2000 and April 2008, five patients diagnosed with arterial esophageal bleeding by conventional angiography, CTangiography or endoscopy, underwent a TAE with NBCA. We mixed NBCA with iodized oil at ratios of 1:1 to 1:4 to supply radiopacity and achieve a proper polymerizatio

11
Article|15 citations·2008
Aortic Stenosis: Evaluation with Multidetector CT Angiography and MR Imaging
전은주, 최상일, 임청, 박계현, 장혁재, 최동주, 김동훈, 이활, 박재형

Aortic valvular stenosis (AS) is the most common valve disease which results in the need for a valve replacement. Although a Doppler echocardiography is the current reference imaging method, the multidetector computerized tomograpghy (MDCT) and magnetic resonance imaging (MRI) have recently emerged as a promising method for noninvasive valve imaging. In this study, we briefly describe the usefulness and comparative merits of the MDCT and MRI for the evaluation of AS in terms of valvular morpholo

12
Article|10 citations·2012
Selective Embolization for Post-Endoscopic Sphincterotomy Bleeding: Technical Aspects and Clinical Efficacy
소영호, 최영호, 정진욱, 제환준, 송순영, 박재형

Objective: The objective of this study was to evaluate the technical aspects and clinical efficacy of selective embolization for post-endoscopic sphincterotomy bleeding. Materials and Methods: We reviewed the records of 10 patients (3%; M:F = 6:4; mean age, 63.3 years) that underwent selective embolization for post-endoscopic sphincterotomy bleeding among 344 patients who received arteriography for nonvariceal upper gastrointestinal bleeding from 2000 to 2009. We analyzed the endoscopic procedur

13
Article|9 citations·2011
Three-Dimensional Evaluation of the Anatomic Variations of the Femoral Vein and Popliteal Vein in Relation to the Accompanying Artery by Using CT Venography
박은아, 정진욱, 이활, Yong Hu Yin, 하종원, 김상준, 박재형

Objective: We wanted to describe the three-dimensional (3D) anatomic variations of the femoral vein (FV) and popliteal vein (PV) in relation to the accompanying artery using CT venography. Materials and Methods: We performed a retrospective review of 445 bilateral (890 limbs) lower limb CT venograms. After the 3D relationship between the FV and PV and accompanying artery was analyzed, the presence or absence of variation was determined and the observed variations were classified. In each patient

14
Article|8 citations·2011
Hepatocellular Carcinomas Smaller Than 4 cm Supplied by the Intercostal Artery: Can We Predict Which Intercostal Artery Supplies the Tumor?
허세범, 김효철, 정진욱, 김민욱, 김지대, 김경민, 이인준, 김영일, 제환준, 박재형

Objective: To predict which intercostal artery supplies a tumor by examining the spatial relationship between hepatocellular carcinoma (HCC) and the intercostal artery feeding the tumor on transverse computed tomography (CT) images. Materials and Methods: Between January 2000 and September 2009, 46 intercostal arteries supplying HCCs smaller than 4 cm were noted in 44 patients, and CT scans and angiograms of these patients were retrospectively reviewed. The intercostal artery feeding the tumor w

15
Article|8 citations·2012
Effects of Arsenic Trioxide on Radiofrequency Ablation of VX2 Liver Tumor: Intraarterial versus Intravenous Administration
성낙종, 윤창진, 강성권, 정진욱, 김효철, 박재형

Objective: Arsenic trioxide (As2O3) can be used as a possible pharmaceutical alternative that augments radiofrequency (RF) ablation by reducing tumor blood flow. The aim of this study was to assess the effect of intraarterial and intravenous administration of As2O3 on RF-induced ablation in an experimentally induced liver tumor. Materials and Methods: VX2 carcinoma was grown in the livers of 30 rabbits. As2O3 (1 mg/kg) was administered through the hepatic artery (n = 10, group A) or ear vein (n

Dive deeper into Jae Hyeung Park's research on Nubint

Open this lab's papers in the app to read with AI, summarize, and cite in your writing.