Skip to main content

Jae Woong Choi

Seoul National University · Medicine

About the Lab

Professor Jae Woong Choi's research lab specializes in structural and interventional cardiology, with a strong focus on transcatheter and surgical valve interventions, anticoagulation strategies in prosthetic heart valves, and risk prediction models for cardiac surgery. The lab investigates clinical outcomes, prosthesis-related complications such as subaortic pannus formation, and the efficacy and safety of non-vitamin K oral anticoagulants in patients with bioprosthetic heart valves. Their work integrates large-scale database analyses with echocardiographic and surgical outcomes to improve patient-centered decision-making in valvular and structural heart disease.

transcatheter aortic valve replacementbioprosthetic heart valvessubaortic pannusanticoagulation in prosthetic valvessurgical risk prediction models

Research Overview

Papers
108
Total Citations
761
Papers (5y)
48
Primary Field
Medicine

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
48total
2022
2023
2024
2025
2026
Citations per year (5y)
100total
20222023202420252026

Selected Papers

15
1
Article|278 citations·2002
Analysis of errors in medical rapid prototyping models
Jae Woong Choi, J.-H. Choi, Youngseob Kim, Y. Kim, J.-K. Lee, M.-K. Kim, J.-H. Lee, M.-J. Kim
SJR Q1International Journal of Oral and Maxillofacial Surgery
Biomedical EngineeringEngineering
2
Review|41 citations·2017
Repair versus replacement for the surgical correction of tricuspid regurgitation: a meta-analysis
Jae Woong Choi, Myoung‐jin Jang, Kyung Hwan Kim, Ho Young Hwang
SJR Q1European Journal of Cardio-Thoracic SurgeryOA

This meta-analysis indicates that TVr is more beneficial compared with TVR in terms of all-cause mortality. From the available data, TVr is not associated with an increased risk of tricuspid reoperation compared with TVR.

Cardiology and Cardiovascular MedicineMedicine
3
Article|37 citations·2020
Equivalent 10-year angiographic and long-term clinical outcomes with saphenous vein composite grafts and arterial composite grafts
Ho Young Hwang, Yeiwon Lee, Suk Ho Sohn, Jae Woong Choi, Ki‐Bong Kim
SJR Q1Journal of Thoracic and Cardiovascular SurgeryOA
SurgeryMedicine
4
Article|22 citations·2020
Early Surgery versus Watchful Waiting in Patients with Moderate Aortic Stenosis and Left Ventricular Systolic Dysfunction
Inki Moon, Minkwan Kim, Jae Woong Choi, Jun‐Bean Park, Ho-Young Hwang, Hyung‐Kwan Kim, Yong‐Jin Kim, Kyung Hwan Kim, Ki‐Bong Kim, Dae‐Won Sohn, Seung‐Pyo Lee
SJR Q2Korean Circulation JournalOA

In patients with moderate AS and LVSD, AVR reduces the risk of all-cause death. A prospective randomized trial is warranted to confirm our findings.

Cardiology and Cardiovascular MedicineMedicine
5
Article|20 citations·2020
Fifteen-Year Outcomes After Bioprosthetic and Mechanical Tricuspid Valve Replacement
Yoonjin Kang, Ho Young Hwang, Suk Ho Sohn, Jae Woong Choi, Kyung Hwan Kim, Ki‐Bong Kim
SJR Q1The Annals of Thoracic Surgery
Cardiology and Cardiovascular MedicineMedicine
6
Article|19 citations·2019
Twenty-Year Experience With Off-Pump Coronary Artery Bypass Grafting and Early Postoperative Angiography
Ki‐Bong Kim, Jae Woong Choi, Se Jin Oh, Ho Young Hwang, Jun Sung Kim, Jaesung Choi, Cheong Lim
SJR Q1The Annals of Thoracic SurgeryOA
SurgeryMedicine
7
Article|8 citations·2021
Incidence and Risk Factors of Pannus after Mechanical Aortic Valve Replacement
Jae Woong Choi, Ho Young Hwang, Yeiwon Lee, Suk Ho Sohn, Kyung Hwan Kim, Ki‐Bong Kim, Hyuk Ahn
SJR Q2The Thoracic and Cardiovascular Surgeon

BACKGROUND: This study was conducted to evaluate the occurrence rate and risk factors of subaortic pannus (SAP) after bileaflet mechanical aortic valve (AV) replacement. METHODS: Between 1990 and 2014, 862 patients underwent primary AV replacement with bileaflet mechanical prosthesis. SAP was defined as (1) gradual increase in mean pressure gradient through mechanical AV without any evidence of motion limitation of the leaflets on echocardiography and (2) AV mean pressure gradient >40 mm Hg or A

Cardiology and Cardiovascular MedicineMedicine
8
Article|7 citations·2022
Effectiveness and safety of non-vitamin K direct oral anticoagulants in atrial fibrillation patients with bioprosthetic valve
Inki Moon, Tae‐Hwa Go, Jang‐Young Kim, Dae Ryong Kang, Suk Ho Sohn, Hyun‐Jung Lee, Jae Woong Choi, Jun‐Bean Park, Ho-Young Hwang, Hyung‐Kwan Kim, Yong‐Jin Kim, Kyung Hwan Kim
SJR Q1PLoS ONEOA

BACKGROUND: Non-vitamin K direct oral anticoagulant (DOAC) is effective for prevention of embolic events in nonvalvular atrial fibrillation (AF) patients. However, the effectiveness and safety of DOAC in AF patients who have bioprosthetic heart valve (BPHV) is largely unknown. METHODS: We retrospectively identified patients with AF and BPHV, using the diagnostic code and medical device and surgery information from the Korean National Health Insurance Service database, between 2013 and 2018. A 1:

Cardiology and Cardiovascular MedicineMedicine
9
Article|5 citations·2022
Trends in Heart Valve Surgery in Korea: A Report from the Heart Valve Surgery Registry Database
Jae Woong Choi, Joon Bum Kim, Yoo Jin Jung, Ho Young Hwang, Kyung Hwan Kim, Jae Suk Yoo, Sak Lee, Seung Hyun Lee, Kiick Sung, Hyung Gon Je, Mi Hee Lim, Byung‐Chul Chang
SJR Q3Journal of Chest SurgeryOA

The recent data from the KHVSR showed increasing trends for complex procedures and minimally invasive surgery in heart valve surgery in Korea, and demonstrated remarkably low risks of operative mortality.

Cardiology and Cardiovascular MedicineMedicine
10
Article|5 citations·2021
The Performance of the Current Risk Prediction Scoring Systems in Patients Undergoing Anaortic Off-pump Coronary Artery Bypass Grafting
Jae Woong Choi, Ho Young Hwang, Ki‐Bong Kim
SJR Q2Journal of Korean Medical ScienceOA

BACKGROUND: This study aimed to evaluate the performance of the Society of Thoracic Surgeons (STS) risk model and European System for Cardiac Operative Risk Evaluation (EuroSCORE) II for patients undergoing anaortic off-pump coronary artery bypass grafting (OPCAB). METHODS: From January 2010 to June 2017, 1,048 patients (isolated anaortic OPCAB: 1,043, on-pump conversion:5) undergoing isolated anaortic OPCAB were enrolled. The STS risk score and EuroSCORE II were calculated with dedicated online

SurgeryMedicine
11
Article|5 citations·2021
Early and Two-year Outcomes after Sutureless and Conventional Aortic Valve Replacement: a Nationwide Population-based Study
Jae Woong Choi, Ho Jin Kim, Joon Bum Kim, Sak Lee, Cheong Lim, Byung‐Chul Chang, Youshin Suh, Na Rae Lee, Ho Young Hwang
SJR Q2Journal of Korean Medical ScienceOA

Early and 2-year clinical outcomes between SAVR and CAVR were not different except for a high rate of permanent pacemaker implantation in the SAVR group.

Cardiology and Cardiovascular MedicineMedicine
12
Article|5 citations·2024
Outcomes of Leaflet Resection vs Chordal Replacement for Degenerative Mitral Regurgitation
Jae Woong Choi, Muath Bishawi, Brittany A. Zwischenberger, Jeffrey G. Gaca, Keith W. Carr, Donald D. Glower
SJR Q1The Annals of Thoracic Surgery
Cardiology and Cardiovascular MedicineMedicine
13
Article|4 citations·2022
Long-term results of a stented bioprosthetic valve in the aortic position: structural valve deterioration and valve haemodynamic deterioration of bovine pericardial and porcine valves
Yoo Jin Jung, Jae Woong Choi, Yoonjin Kang, Ji Seong Kim, Suk Ho Sohn, Ho Young Hwang, Kyung Hwan Kim
SJR Q1European Journal of Cardio-Thoracic Surgery

OBJECTIVES: This study compared the clinical outcomes of bovine and porcine bioprosthetic valves based on structural valve deterioration (SVD) and valve haemodynamic deterioration (VHD) in the aortic position. METHODS: From January 1995 to December 2014, patients who underwent aortic valve replacement (AVR) using a bovine pericardial valve or porcine valve were enrolled. SVD and VHD were defined according to the mean transprosthetic gradient and the grade of aortic regurgitation on transthoracic

Cardiology and Cardiovascular MedicineMedicine
14
Article|2 citations·2020
Optimal Tricuspid Annular Size for Tricuspid Annuloplasty in Patients with Less-Than-Moderate Functional Tricuspid Regurgitation
Jae Woong Choi, Kyung Hwan Kim, Su Chan Lim, Sue Hyun Kim, Suk Ho Sohn, Yeiwon Lee, Ho Young Hwang
The Korean Journal of Thoracic and Cardiovascular SurgeryOA

BACKGROUND: We evaluated the association between tricuspid annular dilatation and the development of moderate or severe tricuspid regurgitation (TR). Additionally, we determined the optimal tricuspid annular dilatation threshold to use as an indicator for tricuspid annuloplasty in patients with less-than-moderate functional TR (FTR). METHODS: Between August 2007 and December 2014, 227 patients with less-than-moderate TR underwent mitral valve surgery without a tricuspid valve (TV) procedure. The

Cardiology and Cardiovascular MedicineMedicine
15
Article|1 citations·2023
Clinical characteristics of apixaban prescription in AF patients with single dose-reduction criterion: ASPIRE (efficacy and safety of apixaban in real-world practice in Korean frail patients with AF)
Jae Woong Choi, S R Lee, Eue‐Keun Choi, Jong‐Il Choi, Sang Won Han, Seil Oh
SJR Q1European Heart JournalOA

Abstract Background/Introduction Previous observational studies reported that off-label underdosed apixaban might be associated with a higher risk of stroke. However, the real-world clinical practice data on the off-label underdosed apixaban in patients with atrial fibrillation (AF) who meet single dose reduction criteria remains scarce. Purpose This study aimed to evaluate the apixaban dosing pattern in patients with AF who met a single dose reduction criterion. The difference in clinical chara

Cardiology and Cardiovascular MedicineMedicine

Research Areas

Cardiology and Cardiovascular MedicineSurgeryPulmonary and Respiratory MedicineBiomedical EngineeringNephrologyOphthalmology

Dive deeper into Jae Woong Choi's research on Nubint

Open this lab's papers in the app to read with AI, summarize, and cite in your writing.