Jae‐Hwan Lee
Yonsei University · Medicine
About the Lab
Professor Jae-Hwan Lee's research lab specializes in biomedical engineering and advanced materials, with a focus on developing implantable and biodegradable devices for targeted medical applications. The lab investigates innovative drug delivery systems, particularly ocular implants with micro-/nanochannel architectures, and designs ultra-sensitive, biodegradable strain sensors for real-time monitoring of physiological microdeformations in cardiovascular and muscular systems. A key emphasis is on translating novel materials—such as PDMS and molybdenum disulfide—into clinically relevant, biocompatible, and biodegradable solutions for disease diagnosis and treatment.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15A typical enhancement of HCCs on MDCT was not unusual (43.6%) and WD and PD HCCs account for most of the atypical enhancement patterns. Early washout favoured MD and PD HCCs rather than WD HCCs, whereas in our study the presence of intratumoral aneurysm was a highly specific finding for PD HCC.
Four popular thermally desorbable adsorbents used for air sampling (Tenax TA, Tenax GR, Carbopack B, and Carbopack X) are examined for the potential to form artifacts with ozone (O3) at environmental concentrations. The performance of these adsorbents for the ketone and aldehyde species identified as O3-adsorbent artifacts was also characterized, including recovery, linearity, and method detection limits (MDLs). Using gas chromatography/mass spectrometry, 13 different artifacts were identified a
PURPOSE: The effects of UVB radiation on the proliferation and differentiation of epidermal keratinocytes were investigated with respect to timing, dosage, and repeated exposures. METHODS: Nine healthy volunteers were placed into three subgroups and exposed to UVB radiation on buttock skin using a Waldmann UV 800 unit fitted with Philips TL-20W/12 fluorescent lamps. Three volunteers were given 2 MED of UVB and biopsied at: pre-exposure, 24, 48 and 72 h after UVB exposure. For three volunteers, 1
Ocular diseases, such as, glaucoma, age-related macular degeneration (AMD), diabetic retinopathy, and retinitis pigmentosa require drug management in order to prevent blindness and affecting million of adults in USA and worldwide. There is an increasing need to develop devices for drug delivery to address ocular diseases. This study focuses on the design, simulation, and development of an implantable ocular drug delivery device consisting of micro-/nanochannels embedded between top and bottom co
We present the first estimate of the prevalence of GCD2. Although uncommon, the prevalence of GCD2 in Korea is greater than anticipated. We believe that our approach could potentially be applied to estimating the prevalence of other rare diseases.
Abstract A fully biodegradable, ultra‐sensitive, and soft strain sensor is pivotal for temporary, real‐time monitoring of microdeformations, crucial in disease diagnosis, surgical precision, and prognosis of muscular, and vascular conditions. Nevertheless, the strain sensitivity of previous biodegradable sensors, denoted by gauge factor (GF) up to ≈100, falls short of requirements for complex biomedical monitoring scenarios, specifically monitoring cardio‐cerebrovascular diseases with microscale
BACKGROUND & AIMS: Previous studies demonstrated conflicting results regarding the association between non-alcoholic fatty liver disease (NAFLD) and atrial fibrillation (AF). The statistical power was not sufficient because of modest sample sizes of these studies. We analysed a large population-based cohort to evaluate the association between NAFLD and AF. METHODS: We evaluated 334 280 healthy individuals without comorbidities who underwent National Health check-ups in South Korea from 2009 to 2
OBJECTIVE: The aim of this study was to compare effectiveness of the Sirolimus- (SES) and Paclitaxel-eluting stent (PES) in primary angioplasty for acute ST-elevation myocardial infarction (STEMI). BACKGROUND: It has been reported that SES and PES have been more effective than bare-metal stents in reducing restenosis and cardiac events in a broad range of patients with coronary artery disease. However, it is unknown whether there may be differences between these two drug-eluting stents in terms
We study conformational transitions of a polymer on a simple-cubic lattice by calculating the zeros of the exact partition function, up to chain length 24. In the complex temperature plane, two loci of the partition function zeros are found for longer chains, suggesting the existence of both the coil-globule collapse transition and the melting-freezing transition. The locus corresponding to coil-globule transition clearly approaches the real axis as the chain length increases, and the transition
Our results indicated that risk factors associated with PBSI included the number of catheter lumens, the use of PICCs for chemotherapy, and the hospital length of stay. Furthermore, PBSI-related death was common in patients undergoing chemotherapy, diabetics, and elderly patients.
Research Areas
Dive deeper into Jae‐Hwan Lee's research on Nubint
Open this lab's papers in the app to read with AI, summarize, and cite in your writing.