Kee Young Lee
Seoul National University · Environmental Science
About the Lab
Professor Kee Young Lee's research lab focuses on indoor and outdoor air quality, with a particular emphasis on atmospheric pollutants such as nitrogen oxides (NO₂), ozone (O₃), and nitrous acid (HONO). The lab investigates the sources, transformation, and health impacts of these pollutants in residential environments, using passive sampling and field monitoring to assess exposure levels. Research also extends to environmental health, including the effects of indoor air quality on children and vulnerable populations, as well as the sociocultural dimensions of environmental representation in media. The lab integrates environmental science, atmospheric chemistry, and public health to understand and mitigate exposure risks in everyday living environments.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15Nitrous acid (HONO) may be generated by heterogeneous reactions of nitrogen dioxide and direct emission from combustion sources. Interactions among nitrogen oxides and ozone are important for outdoor photochemical reactions. However, little is known of indoor HONO levels or the relationship between residential HONO, NO(2), and O(3) concentrations in occupied houses. Six-day integrated indoor and outdoor concentrations of the three pollutants were simultaneously measured in two communities in Sou
Bacterial toxin-antitoxin (TA) systems have received increasing attention for their diverse identities, structures, and functional implications in cell cycle arrest and survival against environmental stresses such as nutrient deficiency, antibiotic treatments, and immune system attacks. In this review, we describe the biological functions and the auto-regulatory mechanisms of six different types of TA systems, among which the type II TA system has been most extensively studied. The functions of
In urban and suburban settings, indoor ozone exposures can represent a significant fraction of an individual's total exposure. The decay rate, one of the factors determining indoor ozone concentrations, is inadequately understood in residences. Decay rates were calculated by introducing outdoor air containing 80-160 parts per billion ozone into 43 residences and monitoring the reduction in indoor concentration as a function of time. The mean decay rate measured in the living rooms of 43 Southern
Mass-circulation magazines were analyzed for the frequency and nature of advertising portrayals of Asian Americans, along several dimensions related to the “model minority” stereotype. Findings were compared with those for African Americans and Hispanics. Despite some improvement in the frequency and scope of representation, the presence of Asian Americans is still limited to narrowly defined stereotypical roles. Logistic regression analyses provided further support for the findings. Drawing on
An ozone (O3) exposure study was conducted in Nashville, TN, using passive O3 samplers to measure six weekly outdoor, indoor, and personal O3 exposure estimates for a group of 10- to 12-yr-old elementary school children. Thirty-six children from two Nashville area communities (Inglewood and Hendersonville) participated in the O3 sampling program, and 99 children provided additional time-activity information by telephone interview. By design, this study coincided with the 1994 Nashville/Middle Te
Residential thermal conditions are important because people spend the majority of their time in the home environment. Indoor temperature and relative humidity (RH) were measured continuously over 1 year in 14 residences in Seoul, Korea. The relationship between residential indoor and outdoor conditions were determined by four meteorological parameters—temperature, apparent temperature (AT), RH, and absolute humidity (AH). Outdoor and indoor temperature, and AT and AH were closely correlated, but
Biomass fuel is used for cooking and heating, especially in developing countries. Combustion of biomass fuel can generate high levels of indoor air pollutants, including particulate matter (PM) and volatile organic compounds (VOCs). This study characterized PM and VOC emissions from cow dung combustion in a controlled experiment. Dung from grass-fed cows was dried and combusted using a dual-cone calorimeter. Heat fluxes of 10, 25, and 50 kW/m(2) were applied. The concentrations of PM and VOCs we
The aim of this study was to determine characteristics of personal exposure to inorganic and organic dust during manual harvest operations of California citrus and table grapes. Personal exposures to inhalable dust and respirable dust were measured five times over a 4-month period of harvesting season. We analyzed components of the dust samples for mineralogy, respirable quartz, endotoxin, and total and culturable microorganisms. Workers manually harvesting were exposed to a complex mixture of i
INTRODUCTION: Smoke-free air laws have been implemented in many Kentucky communities to protect the public from the harmful effects of secondhand smoke exposure. The impact of different strengths of smoke-free air laws on indoor air quality was assessed. METHODS: Indoor air quality in hospitality venues was assessed in seven communities before and after comprehensive smoke-free air laws and in two communities only after partial smoke-free air laws. One community was measured three times: before
Research Areas
Dive deeper into Kee Young Lee's research on Nubint
Open this lab's papers in the app to read with AI, summarize, and cite in your writing.