Skip to main content

Kim Kwang Pyoo

Kyung Hee University · Engineering

About the Lab

Professor Kim Kwang Pyoo's research lab specializes in radiation protection and internal dosimetry, with a focus on occupational radiation exposure in medical and industrial settings. The lab investigates radiation doses to interventional cardiologists and other medical staff during fluoroscopically guided procedures, as well as inhalation exposure risks in the phosphate industry due to naturally occurring radioactive materials (NORM/TENORM). Key research directions include aerosol characterization, particle size distribution, radionuclide solubility, and the development of accurate dose assessment methodologies using advanced sampling and computational tools. The lab emphasizes reducing dose uncertainty through direct measurement and improved modeling for better worker health protection.

radiation protectioninternal dosimetryaerosol characterizationoccupational exposureNORM/TENORM

Research Overview

Papers
148
Total Citations
1,005
Papers (5y)
71
Primary Field
Engineering

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
71total
2022
2023
2024
2025
2026
Citations per year (5y)
34total
20222023202420252026

Selected Papers

15
1
Review|280 citations·2008
OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING CARDIAC CATHETERIZATION PROCEDURES
Kwang Pyo Kim, Donald L. Miller, Stephen Balter, Ruth A. Kleinerman, Martha S. Linet, Deukwoo Kwon, Steven L. Simon
SJR Q3Health Physics

Cardiac catheterization procedures using fluoroscopy reduce patient morbidity and mortality compared to operative procedures. These diagnostic and therapeutic procedures require radiation exposure to patients and physicians. The objectives of the present investigation were to provide a systematic comprehensive summary of the reported radiation doses received by operators due to diagnostic or interventional fluoroscopically-guided procedures, to identify the primary factors influencing operator r

Radiology, Nuclear Medicine and ImagingMedicine
2
Review|113 citations·2009
Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review
Kwang Pyo Kim, Donald L. Miller
SJR Q3Radiation Protection DosimetryOA

What is known about radiation exposure to physicians who perform cardiac interventions is reviewed and various factors that affect their exposure are discussed. There are wide variations in the radiation dose (up to 1000-fold) per procedure. Despite extensive improvements in equipment and technology, there has been little or no reduction in dose over time. The wide variation and lack of reduction in operator doses strongly suggests that more attention must be paid to factors influencing the oper

Radiology, Nuclear Medicine and ImagingMedicine
3
Article|14 citations·2009
Wall conditioning of the KSTAR vacuum vessel
Kyungmin Kim, Kyungmin Kim, H.L. Yang, Suk‐Ho Hong, S.T. Kim, H.T. Kim, Kwang Pyo Kim, Kwang Pyo Kim, K.S. Lee, H.K. Kim, J.S. Bak
SJR Q1Fusion Engineering and Design
Nuclear and High Energy PhysicsPhysics and Astronomy
4
Article|14 citations·2006
Characterization of Radioactive Aerosols in Florida Phosphate Processing Facilities
Kwang Pyo Kim, Chang‐Yu Wu, Brian K. Birky, Wesley Nall, Wesley E. Bolch
SJR Q2Aerosol Science and TechnologyOA

The health risks to workers in the Florida phosphate industry resulting from chronic inhalation of radionuclide-containing aerosols have not been adequately addressed. The present study establishes a database of information on the particle size distribution, density, shape, chemical composition, and radioactivity concentration for six phosphate facilities in the northern and central regions of the state. A seven-stage cascade impactor was employed to sample aerosols at various processing areas i

Radiological and Ultrasound TechnologyHealth Professions
5
Article|13 citations·2019
Commissioning of vacuum pumping devices of the second KSTAR neutral beam injection system
Kwang Pyo Kim, H.T. Park, H.T. Kim, K.S. Lee, N.H. Song, S.W. Kwag, Y.B. Chang, W. Cho, J.S. Kim, Junhyung Jeong, K.R. Park, Y.S. Kim
SJR Q1Fusion Engineering and Design
Aerospace EngineeringEngineering
6
Article|13 citations·2009
Overview of the KSTAR vacuum pumping system
Kwang Pyo Kim, K.S. Lee, H.L. Yang, M.K. Kim, H.K. Kim, G.H. Kim, Kyungmin Kim, H.T. Kim, K.H. Kim, M.K. Park, Y.K. Oh, J.S. Bak
SJR Q1Fusion Engineering and Design
Biomedical EngineeringEngineering
7
Article|8 citations·2005
EFFECTIVE DOSE SCALING FACTORS FOR USE WITH CASCADE IMPACTOR SAMPLING DATA IN TENORM INHALATION EXPOSURES
Kwang Pyo Kim, Chang‐Yu Wu, Brian K. Birky, Wesley E. Bolch
SJR Q3Health Physics

When assessing the effective dose to workers following radio-aerosol inhalation exposures, significant reductions in dose uncertainty can be achieved through direct measurement of the particle-size distribution. The University of Washington Mark III cascade impactor is one such air sampling device that permits the user to determine aerosol mass and radioactivity concentrations as a function of particle size within eight different size intervals (each corresponding to a different impactor stage o

Statistics, Probability and UncertaintyDecision Sciences
8
Article|8 citations·2011
CT dosimetry computer codes: their influence on radiation dose estimates and the necessity for their revision under new ICRP radiation protection standards
Kwang Pyo Kim, Jaekook Lee, Wesley E. Bolch
SJR Q3Radiation Protection Dosimetry

Computed tomography (CT) dosimetry computer codes have been most commonly used due to their user friendliness, but with little consideration for potential uncertainty in estimated organ dose and their underlying limitations. Generally, radiation doses calculated with different CT dosimetry computer codes were comparable, although relatively large differences were observed for some specific organs or tissues. The largest difference in radiation doses calculated using different computer codes was

Radiology, Nuclear Medicine and ImagingMedicine
9
Article|7 citations·2006
TENORM aerosols in the Florida phosphate industry—assessment of lung fluid solubility and annual effective dose to workers
Kwang Pyo Kim, Chang‐Yu Wu, Brian K. Birky, Wesley E. Bolch
SJR Q3Radiation Protection Dosimetry

Inhalation exposure to workers in the Florida phosphate industry due to TENORM aerosols has not been adequately addressed owing to lack of aerosol information. One of the more critical factors is the absorption rate of inhaled radionuclides into blood. In this study, this parameter was characterised using an in vitro dissolution test. The solubility data and other aerosol information were then used for individualised dose assessments at six different Florida phosphate facilities. The solubility

Radiological and Ultrasound TechnologyHealth Professions
10
Article|6 citations·2018
Calculation of dose conversion coefficients for radioactive cesium in contaminated soil by depth and density
Il Park, Jin O Lee, Tae Gwan, Min Jun Kim, A-la Go, Kwang Pyo Kim
SJR Q2Journal of Radioanalytical and Nuclear Chemistry
Global and Planetary ChangeEnvironmental Science
11
Article|4 citations·2016
Radiobioassay performance evaluation of urine and faeces samples for radiation emergency preparedness
Jaeryong Yoo, Seyoung Park, Seokwon Yoon, Wi-Ho Ha, Seung‐Sook Lee, Kwang Pyo Kim
SJR Q2Journal of Nuclear Science and TechnologyOA

In the event of a radiation emergency, it is necessary to assess intake and radiation dose for the internally contaminated casualties. This paper provides relatively rapid and simple procedures of bioassay. Faeces samples were ashed to improve sample homogeneity. Gamma spectrometry was used for radioactivity measurement. The measured results, including activity of the biosamples and associated uncertainty, were evaluated for traceability based on ANSI N42.22 and bias and precision based on ANIS/

Global and Planetary ChangeEnvironmental Science
12
Article|3 citations·2024
Current trends in cyclotrons and Radionuclide production: A comprehensive analysis in the Republic of Korea
M. J. Kim, H. Kim, Jae Wan Kwon, Kwang Pyo Kim
SJR Q2Nuclear Engineering and TechnologyOA

Over the past few decades, the use of cyclotrons in medical applications has expanded significantly worldwide. This study aims to analyze the current status and trends of cyclotrons and radionuclide production in the Republic of Korea, utilizing national survey results and regulatory databases. Between 1985 and 2023, a total of 51 cyclotrons were installed in the Republic of Korea. As of now, 35 cyclotrons are operational, 14 have been shut down, and 2 have been decommissioned. The distribution

Radiology, Nuclear Medicine and ImagingMedicine
13
Article|2 citations·2023
Derivation of site-specific derived concentration guideline levels at Korea Research Reactor 1 and 2 sites using probabilistic analysis
Geun-Ho Kim, Min-Seong Kim, Gangwoo Ryu, Se-Jong Lee, Kwang Pyo Kim, Se-Jong Lee, Kwang Pyo Kim
SJR Q2Applied Radiation and Isotopes
Materials ChemistryMaterials Science
14
Article|2 citations·2023
Derivation of dose constraint for the general public around nuclear power plants with operational data of radioactive effluent releases
Yong Ho Jin, Ji Woo Kim, Hyeok Jae Kim, Kwang Pyo Kim, Hyeok Jae Kim, Kwang Pyo Kim
SJR Q2Applied Radiation and Isotopes
Radiological and Ultrasound TechnologyHealth Professions
15
Article|1 citations·2025
Assessment of radiation dose for opening and closing the steam generator primary manways during the overhaul period
Ju Young Kim, Dae Ho Lee, Geon Woo Son, Kwang Pyo Kim, Kwang Pyo Kim
SJR Q2Applied Radiation and Isotopes
Electrical and Electronic EngineeringEngineering

Research Areas

Biomedical EngineeringMaterials ChemistryRadiological and Ultrasound TechnologyRadiology, Nuclear Medicine and ImagingNuclear and High Energy PhysicsGlobal and Planetary Change

Dive deeper into Kim Kwang Pyoo's research on Nubint

Open this lab's papers in the app to read with AI, summarize, and cite in your writing.