Skip to main content

Kwang-woo Kim

Seoul National University · Medicine

About the Lab

Professor Kwang-woo Kim's research lab focuses on sustainable building technologies and energy-efficient systems, with a strong emphasis on thermal energy management in residential and commercial buildings. Key research directions include thermally activated building systems (TABS), energy balancing systems (EBS), and housing performance evaluation models that support data-driven decision-making in construction and real estate. The lab also explores biomedical applications, particularly in understanding oxidative stress mechanisms in neuropathic pain and the clinical interplay between inflammatory diseases such as IBD and AD.

thermally activated building systemsenergy balancing systemshousing performance evaluationoxidative stressinflammatory disease mechanisms

Research Overview

Papers
224
Total Citations
1,783
Papers (5y)
11
Primary Field
Medicine

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
11total
2020
2021
2022
2023
2025
Citations per year (5y)
9total
20202021202220232025

Selected Papers

15
1
Article|84 citations·2010
Effect of MRT variation on the energy consumption in a PMV-controlled office
Dong Hwa Kang, Paek Hyoun Mo, Dong Hee Choi, Seung‐Yeong Song, Myoung Souk Yeo, Kwang Woo Kim
SJR Q1Building and Environment
Building and ConstructionEngineering
2
Article|52 citations·2010
Effect of bake-out on reducing VOC emissions and concentrations in a residential housing unit with a radiant floor heating system
Dong Hwa Kang, Dong Hee Choi, Seung Min Lee, Myoung Souk Yeo, Kwang Woo Kim
SJR Q1Building and Environment
Process Chemistry and TechnologyChemical Engineering
3
Article|42 citations·2016
Effects of the geothermal load on the ground temperature recovery in a ground heat exchanger
Seung Hyo Baek, Myoung Souk Yeo, Kwang Woo Kim
SJR Q1Energy and Buildings
Renewable Energy, Sustainability and the EnvironmentEnergy
4
Article|22 citations·2017
Control of Thermally Activated Building System Considering Zone Load Characteristics
Woong June Chung, Sang Hoon Park, Myoung Souk Yeo, Kwang Woo Kim
SJR Q1SustainabilityOA

The objectives of this study were to investigate the thermally activated building system (TABS) mechanism for appropriate use of the system and to apply the proper concept of TABS for each zone by using different TABS control strategies. In order to examine the TABS mechanism, dynamic simulation with EnergyPlus was used to model the office building with TABS, because the radiant heat exchange characteristics of the TABS according to the time variable was critical. The typical control concept of

Building and ConstructionEngineering
5
Article|20 citations·2004
공동주택의 거주성능 평가모델 개발에 관한 연구
김광우, 양인호, 김선숙

This paper presents the development of a housing performance evaluation model for multi-unit residential buildings, which is intended to encourage initiative towards achieving better housing performance and to support homebuyers'decision making on housing comparison and selection. Forty-one objective and feasible housing performance indicators were selected from a review of existing evaluation models and interviews with experts, are classified into a series of categories. The weight of each cate

6
Article|14 citations·2015
Economic Feasibility Considering Capacity of Thermal Storage Tank for Energy Balancing System
Min Gi Kim, Goo Sang Joe, Tae Ha Leigh, Dae Uk Shin, Myoung Souk Yeo, Kwang Woo Kim
Energy ProcediaOA

An energy balancing system (EBS) performs heating and cooling by utilizing the refrigerant cycle. As it produces heating and cooling simultaneously, EBS has an advantage when heating and cooling demand occur simultaneously. Furthermore, with increase in a thermal storage capacity, it can conduct energy balancing by heating and cooling which occur at different times. It can result in both an increase in the heating and cooling produced by energy balancing and a reduction in operating cost. Howeve

TransportationSocial Sciences
7
Article|5 citations·2023
Atopic dermatitis is associated with the clinical course of inflammatory bowel disease
Kwang Woo Kim, Seong‐Joon Koh, Hyoun Woo Kang, Hyunsun Park, Hyeonjin Ha, Jin Park, Kyunghoon Kim, Yukyung Jun, Yoo Min Han, Hyun Jung Lee, Hyuk Yoon, Jong Pil Im
SJR Q2Scandinavian Journal of Gastroenterology

Objectives There are a few studies about the relationship between inflammatory bowel disease (IBD) and atopic dermatitis (AD). It is implied that both diseases have common pathophysiologic mechanisms and can affect each other. However, little information is available on the effect of AD on the clinical course of patients with IBD.Methods This is a multi-center, retrospective, observational study. We define AD as a chronic eczematoid dermatosis diagnosed by dermatologists. Patients with concurren

DermatologyMedicine
8
Article|5 citations·2009
Reactive oxygen species and N-methyl-D-aspartate receptor-mediated central sensitization in hindlimb ischemia/reperfusion injury-induced neuropathic pain rats
Kwang Woo Kim, Mi Jin Ha, Kyung‐Young Jung, Kyung Hwa Kwak, Sung-Sik Park, Dong Gun Lim
SJR Q1Korean journal of anesthesiologyOA

This study suggests that ischemia/reperfusion injury induced neuropathic pain model is a good candidate for the research fields of ROS and pain mechanism. The generation of ROS, especially superoxide is partly responsible for NMDA-mediated mechanical allodynia.

PhysiologyMedicine
9
Article|4 citations·2006
커튼월 시스템 벽체부의 단열재 실내측 마감재 파손 여부에 따른 결로 평가 및 내부결로 방지를 위한 효과적 마감재에 관한 연구
김광우, 송승영, 여명석, 강가영

Inside vapour tightness of the structure is very important to prevent interstitial condensation. In curtain wall system, inside finish material for insulation is often taking a role of vapour retarder. However, inside finish material for insulation is easily torn during the construction period due to its weakness. It may cause vapour diffusion and interstitial condensation. Thus this study aims to suggest the efficient inside finish material for insulation to prevent interstitial condensation in

10
Article|4 citations·2015
The thermal output evaluation of radiant heating panels by experiment
Dae Uk Shin, Mi Su Shin, Kyu-Nam Rhee, Seong Ryong Ryu, Chang Ho Jeong, Myoung Souk Yeo, Kwang Woo Kim
SJR Q2Building Services Engineering Research and Technology

The purpose of this study is to make the target condition of experimental assessment based on the standard EN1264. To achieve this purpose, the characteristic errors, which are caused by characteristics of experimental setup and prevent the results from meeting the target condition, should be removed. This study proposes an experimental setup and suggests a control strategy based on standard EN1264. For the specifications of the experimental setup, the essential equipment and the configuration o

Building and ConstructionEngineering
11
Article|3 citations·2015
Energy Performance of Balanced Heat Recovery Systems with Load-Balancing
Dae Uk Shin, Tae Ha Leigh, Goo Sang Joe, Min Gi Kim, Myoung Souk Yeo, Kwang Woo Kim
Energy ProcediaOA

The load-balancing method is to make the different amount of heating and cooling loads to be similar as possible for handling the more load by the balanced heat recovery (BHR) system which has higher energy performance than auxiliary system. When this method is applied, the zone set temperatures should be in comfort range and the additional energy to BHR system should not exceed the energy consumption by auxiliary system of general method. In result, the total energy consumption is lower, and so

Mechanical EngineeringEngineering
12
Article|3 citations·2004
공동주택 현장 실험을 통한 바닥복사냉방의 성능평가
김광우, 여명석, 석호태, 조영흠, 임재한

The objective of this study is to analyze the performance evaluation of the Radiant Floor Cooling and the dehumidification system included in the integrated system may be utilized as a supplementary cooling device through field experiments. The experiments are performed to evaluate the performance of the radiant floor cooling and confirm the possibility of continuous cooling through the actual field experiments, moreover, analyze specific characters of the radiant floor cooling system according

13
Article|2 citations·2022
Association between severe hepatic steatosis examined by Fibroscan and the risk of high-risk colorectal neoplasia
Kwang Woo Kim, Hyoun Woo Kang, Hosun Yoo, Yukyung Jun, Hyun Jung Lee, Jong Pil Im, Ji Won Kim, Joo Sung Kim, Seong‐Joon Koh, Yong Jin Jung
SJR Q1PLoS ONEOA

The prevalence of colorectal neoplasm in patients with non-alcoholic fatty liver disease has increased twice as high as that in the general population. FibroScan is a new modality for evaluating hepatic steatosis. This study aimed to investigate the relationship between the risk of high-risk colorectal neoplasia and hepatic steatosis examined using FibroScan. This was a cross sectional study of prospectively enrolled subjects who were scheduled to undergo index colonoscopy as a health screening

EpidemiologyMedicine
14
Article|1 citations·2015
Virtual special issue – Radiant heating and cooling systems
Kwang Woo Kim
SJR Q1Building and Environment
Computational MechanicsEngineering
15
Article|1 citations·1992
HP-GPC Analysis for Characteristics Change of Asphalt Cement Due to Aging
Kwang Woo Kim, Kyu Seok Yeon, Joong Dae Choi
Journal of the Korean Society of Civil Engineers
Civil and Structural EngineeringEngineering

Research Areas

SurgeryPulmonary and Respiratory MedicineAnesthesiology and Pain MedicineBuilding and ConstructionBiomedical EngineeringCardiology and Cardiovascular Medicine

Dive deeper into Kwang-woo Kim's research on Nubint

Open this lab's papers in the app to read with AI, summarize, and cite in your writing.