Skip to main content

Kyeongwon Jeong

Yonsei University · Engineering

About the Lab

Professor Kyeongwon Jeong's research lab specializes in the design of low-power, high-performance analog and mixed-signal integrated circuits for implantable and wearable biomedical systems. The lab focuses on advanced signal acquisition and stimulation techniques for neural interfaces, biopotential recording, and ultrasonic capsule endoscopy, emphasizing power efficiency, wide dynamic range, and artifact tolerance. Key research directions include noise-shaping ADCs, delta-sigma modulators, and customized DAC architectures tailored for real-time neural and physiological signal processing.

biomedical ICsneural interfaceslow-power ADCartifact toleranceultrasonic endoscopy

Research Overview

Papers
18
Total Citations
84
Papers (5y)
14
Primary Field
Engineering

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
14total
2022
2023
2024
2025
2026
Citations per year (5y)
78total
20222023202420252026

Selected Papers

15
1
Article|16 citations·2023
A 15.4-ENOB, Fourth-Order Truncation-Error-Shaping NS-SAR-Nested ΔΣ Modulator With Boosted Input Impedance and Range for Biosignal Acquisition
Kyeongwon Jeong, Sohmyung Ha, Minkyu Je
SJR Q1IEEE Journal of Solid-State Circuits

This article presents a discrete-time <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta \Sigma $ </tex-math></inline-formula> modulator (DSM) with a wide linear input range and high input impedance for biomedical signal acquisition. The proposed integrated circuit (IC) is based on a 1st-order DSM with 2nd-order noise-shaping (NS)-successive approximation (SAR) for high resolution with high power efficienc

Biomedical EngineeringEngineering
2
Article|15 citations·2022
A Reconfigurable Neural Stimulation IC With a High-Resolution Strength Control and In-Situ Neural Recording Function for Cochlear Implant Systems
Woojin Ahn, Doohee Kim, Jong-Hyeok Park, Joeng Hoan Park, Taeju Lee, Kyeongwon Jeong, Kyou Sik Min, Hoseung Lee, Minkyu Je
SJR Q1IEEE Solid-State Circuits Letters

This letter presents a neural stimulation IC for the 32-channel cochlear implant system. A zoom current DAC (I-DAC), whose full range is reconfigured to fit the interval between the comfort (C) and threshold (T) levels, is introduced for high-resolution stimulation strength control to provide high-fidelity sound perception with minimal hardware overhead. The IC also includes an in-situ neural recording function. The effectiveness of auditory nerve stimulation is validated by monitoring electrica

Cognitive NeuroscienceNeuroscience
3
Article|13 citations·2022
A PVT-Robust AFE-Embedded Error-Feedback Noise-Shaping SAR ADC With Chopper-Based Passive High-Pass IIR Filtering for Direct Neural Recording
Kyeongwon Jeong, Yoontae Jung, Gichan Yun, Donghyun Youn, Yehhyun Jo, Hyunjoo J. Lee, Sohmyung Ha, Minkyu Je
SJR Q1IEEE Transactions on Biomedical Circuits and Systems

This paper presents a PVT-robust error-feedback (EF) noise-shaping SAR (NS-SAR) ADC for direct neural-signal recording. For closed-loop bidirectional neural interfaces enabling the next generation neurological devices, a wide-dynamic-range neural recording circuit is required to accommodate stimulation artifacts. A recording structure using an NS-SAR ADC can be a good candidate because the high resolution and wide dynamic range can be obtained with a low oversampling ratio and power consumption.

Biomedical EngineeringEngineering
4
Article|9 citations·2023
A Wide-Bandwidth Ultrasound Receiver and On-Chip Ultrasound Transmitter for Ultrasound Capsule Endoscopy
Kyeongwon Jeong, Gichan Yun, Jaesuk Choi, Injun Choi, Jeehoon Son, Jae Youn Hwang, Sohmyung Ha, Minkyu Je
SJR Q1IEEE Journal of Solid-State Circuits

This article presents an ultrasound (US) transceiver IC including a highly power-efficient US receiver (RX) and a high-voltage (HV) US transmitter (TX) for US capsule endoscopy (USCE) systems for the first time. The proposed USCE system employs the developed IC, a single-element piezoelectric transducer (PZT), and a mechanically rotating reflector to obtain 360° transmural scans while traveling through the gastrointestinal (GI) tract. Since the USCE system operates with a tiny battery, power eff

Radiology, Nuclear Medicine and ImagingMedicine
5
Article|7 citations·2022
A 600mVPP-Input-Range 94.5dB-SNDR NS-SAR-Nested DSM with 4th-Order Truncation-Error Shaping and Input-Impedance Boosting for Biosignal Acquisition
Kyeongwon Jeong, Gichan Yun, Sohmyung Ha, Minkyu Je
2022 IEEE Symposium on VLSI Technology and Circuits (VLSI Technology and Circuits)

We present a 600mV <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">PP</inf> -linear-input-range 94.5dB-SNDR NS-SAR-based DSM with input-impedance (Z <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">IN</inf> ) boosting for biopotential recording. The proposed direct-conversion ADC utilizes a 1 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">st</sup> -order DS

Biomedical EngineeringEngineering
6
Article|7 citations·2022
Dynamic-Range-Enhancement Techniques for Artifact-Tolerant Biopotential-Acquisition ICs
Yoontae Jung, Soon-Jae Kweon, Taeju Lee, Kyeongwon Jeong, Sohmyung Ha, Minkyu Je
SJR Q1IEEE Transactions on Circuits & Systems II Express Briefs

This brief reviews the principle and design of dynamic range (DR) enhancement techniques for artifact-tolerant biopotential-acquisition ICs. In order to record small input signals without being disturbed by large artifacts, which may arise from motion or stimulation, biopotential-acquisition ICs for wearable devices and bidirectional neural interfaces should have wide DR in addition to low noise and high power efficiency. This review discusses key features of DR enhancement techniques based on t

Biomedical EngineeringEngineering
7
Article|4 citations·2021
A 99.5dB-DR 5kHz-BW Closed-Loop Neural-Recording IC based on Continuous-Time Dynamic-Zoom ΔΣ ADC with Automatic AFE-Gain Control
Yoontae Jung, Soon-Jae Kweon, Hyuntak Jeon, Taeju Lee, Injun Choi, Kyeongwon Jeong, Mi Kyung Kim, Hyunjoo J. Lee, Sohmyung Ha, Minkyu Je
2021 IEEE Asian Solid-State Circuits Conference (A-SSCC)

Neural-recording ICs have been a key tool to unravel the mystery of the human brain and find treatments for various neurological diseases. Since neural signals inherently have a small amplitude and suffer from environmental interferences, conventional neural recording circuits have been mainly designed for low noise, high CMRR, and low power, using the structure with a high-gain amplifier and a low-resolution ADC [1] (Fig. 1). With the advent of closed-loop neurotherapeutics, stimulation artifac

Cellular and Molecular NeuroscienceNeuroscience
8
Article|3 citations·2025
A 3.47 NEF 175.2dB FOMs Direct Digitization Front-End Featuring Delta Amplification for Enhanced Dynamic Range and Energy Efficiency in Bio-Signal Acquisition
Kyeongwon Jeong, Can Livanelioglu, Jiawei Liao, Inhee Lee, Taekwang Jang

Bio-signal monitoring systems have recently been widely applied to implantable and wearable devices for healthcare applications. However, they require extremely low-noise front-end circuits to ensure reliable recording while receiving a very small signal (e.g., the amplitude of the EEG ranging from 1 to 100µV [1]). A conventional analog front-end typically achieves a low input-referred noise (IRN) of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$

Biomedical EngineeringEngineering
9
Article|2 citations·2023
A 2pA/√Hz Current-Conveyor-Assisted Ultrasound Receiver with 25pF CMUT Parasitic Capacitance
Gichan Yun, Kyeongwon Jeong, Haidam Choi, Nam SeungHyeon, Chaerin Oh, Hyunjoo J. Lee, Sohmyung Ha, Minkyu Je

Ultrasound (US) imaging has emerged as a promising solution for medical diagnosis with its low cost and biocompatibility. Recent demands for multi-dimensional imaging in medical diagnosis brought a challenge of operating multiple US transducers, especially within miniaturized probes. There have been some studies of US systems for the application of intracardiac echocardiography (ICE) [1] and transesophageal echocardiography (TEE) [2] that require highly integrated systems within miniaturized pro

Radiology, Nuclear Medicine and ImagingMedicine
10
Article|2 citations·2022
A 20-MHz 2.3-mW Receiver and a 25-V Transmitter for Ultrasound Capsule Endoscopy
Kyeongwon Jeong, Jaesuk Choi, Gichan Yun, Injun Choi, Jeehoon Son, Jae Youn Hwang, Sohmyung Ha, Minkyu Je
2022 IEEE Asian Solid-State Circuits Conference (A-SSCC)

Biomedical applications of ultrasound (US) imaging have been extended and diversified. Some recent applications, such as intracardiac echocardiography [1], [2] and the intravascular US [3], require extreme miniaturization of the US imaging system. As another promising application, an ultrasound capsule endoscopy (USCE) is being developed to provide transmural scans of the gastrointestinal tract and enable the detection of deeper pathology [4]. However, the USCE has only been studied by focusing

Radiology, Nuclear Medicine and ImagingMedicine
11
Article|2 citations·2021
A Neural Stimulation IC Based on a Reconfigurable Current DAC with In-Situ Neural Recording Function for Cochlear Implant Systems
Woojin Ahn, Doohee Kim, Jong-Hyeok Park, Jeong Hoan Park, Taeju Lee, Kyeongwon Jeong, Kyou Sik Min, Hoseung Lee, Minkyu Je
2021 IEEE Asian Solid-State Circuits Conference (A-SSCC)

According to the WHO report, the hearing-impaired population in the world is about 470 million in 2019, and about 15 million people could hear sounds with cochlear implants (CIs). In clinical practices, people who have a hearing loss greater than 90dB are guided to use CIs instead of hearing aids to restore hearing. The CI delivers electrical stimulation to auditory nerves through an electrode array which is surgically inserted in a cochlea. The multiple electrodes in the array are placed at dif

Biomedical EngineeringEngineering
12
Article|2 citations·2024
A 5.3-μW 80.8-dB SNDR LNA-Embedded EF-CIFF Third-Order Noise-Shaping SAR ADC for Closed-Loop Neural Recording
Yegeun Kim, Changhun Seok, Kyeongwon Jeong, Haidam Choi, Heewon Choee, Sohmyung Ha, Minkyu Je

This work presents a 3rd-order noise-shaping successive approximation register (NS-SAR) analog-to-digital converter (ADC) employing an error feedback-cascaded integrator feedforward (EF-CIFF) structure where a low-noise amplifier (LNA) is embedded, which operates for neural recording at a low oversampling ratio (OSR). By employing the 3rd-order EFCIFF NS-SAR ADC and embedded low-gain LNA, it achieves low input-referred noise (IRN) while offering a sufficiently wide input range so that stimulatio

BioengineeringChemical Engineering
13
Article|1 citations·2025
An 18.5nF-Input-Range PM-SAR-Hybrid Capacitance-to-Digital Converter Achieving 6.1μs Conversion Time at 18.1pF Input Capacitance
Donghyun Youn, Kyeongwon Jeong, Won Sik Youn, Hoyong Seong, Yechan Park, Sohmyung Ha, Minkyu Je

Capacitive sensors are widely used to acquire various types of physical information. A wide-input-range fast-conversion capacitance-to-digital converter (CDC) with high resolution and energy efficiency can accommodate such diverse applications. Among prior CDC topologies, SAR [1]–[4] and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\Delta\Sigma{M}$</tex> CDCs [5]–[10] show high energy efficiency, but their input range is limited by the voltage s

Electrical and Electronic EngineeringEngineering
14
Article|1 citations·2024
An Ultrasound Receiver With Bandwidth-Enhanced Current Conveyor and Element-Level Ultrasound Transmitter for Ultrasound Imaging Systems
Gichan Yun, Kyeongwon Jeong, Haidam Choi, Seung-Hyun Nam, Chaerin Oh, Hyunjoo J. Lee, Sohmyung Ha, Minkyu Je
SJR Q1IEEE Solid-State Circuits Letters

In this letter, we present an ultrasound (US) imaging system with a low-noise US receiver (RX) and an element-level US transmitter (TX) for a capacitive micromachined ultrasonic transducer (CMUT). The proposed US RX isolates the input parasitic capacitance <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$(C_{P})$ </tex-math></inline-formula> from the front-end transimpedance stage by using a bandwidth-enhanced

Radiology, Nuclear Medicine and ImagingMedicine
15
Article|0 citations·2026
A 3.47 NEF 175.2-dB FoMs Direct Digitization Front-End Featuring Delta Amplification Noise-Shaping SAR ADC for Biosignal Acquisition
Kyeongwon Jeong, Can Livanelioglu, Jiawei Liao, Inhee Lee, Taekwang Jang
SJR Q1IEEE Journal of Solid-State Circuits
Biomedical EngineeringEngineering

Research Areas

Biomedical EngineeringRadiology, Nuclear Medicine and ImagingCognitive NeuroscienceCellular and Molecular NeuroscienceBioengineeringElectrical and Electronic Engineering

Dive deeper into Kyeongwon Jeong's research on Nubint

Open this lab's papers in the app to read with AI, summarize, and cite in your writing.