About the Lab
Professor Simon Song's research lab specializes in microfluidic systems, nanomaterials, and responsive polymers for biomedical and environmental sensing applications. The lab focuses on developing innovative microchip-based platforms that integrate stimuli-responsive materials—such as thermoresponsive polydiacetylenes and photochromic spiropyran-embedded PDMS—with advanced fluidic control strategies. Key research directions include on-chip protein concentration, temperature and gas sensing, and precise flow manipulation in paper-based and microfluidic devices using optical, thermal, and surface engineering approaches. The lab emphasizes low-cost, portable, and highly sensitive diagnostic systems for point-of-care and field-deployable applications.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15Laser-patterning of nanoporous membranes at the junction of a cross channel in a microchip is used to integrate protein concentration with an electrokinetic injection scheme. Upon application of voltage, linear electrophoretic concentration of charged proteins is achieved at the membrane surface because buffer ions can easily pass through the membrane while proteins larger than the molecular weight cutoff of the membrane (>5700) are retained. Simple buffer systems can be used, and the concentrat
A new, microfluidic temperature sensor system, based on a thermoresponsive conjugated polymer supramolecule, has been developed. By generating blue-phase polydiacetylene (PDA) sensor droplets using hydrodynamic instability, we were able to monitor the variation of fluorescent intensity of the droplets with respect to the flow temperature.
Chip-level integration of microdialysis membranes is described using a novel method for in situ photopatterning of porous polymer features. Rapid and inexpensive fabrication of nanoporous microdialysis membranes in microchips is achieved using a phase separation polymerization technique with a shaped UV laser beam. By controlling the phase separation process, the molecular weight cutoffs of the membranes can be engineered for different applications. Counterflow dialysis is used to demonstrate ex
A highly sensitive, tunable, flexible and microfluidic compatible gas sensor was developed based on a photochromic spiropyran-embedded PDMS composite.
Paper-based microfluidic devices have recently attracted attention for their ability to utilize the inherent capillary force, or absorptivity, of paper to generate flows instead of requiring an external force. This allows for a simple sensor system that can be readily manufactured at low costs; however, sophisticated flow control is still necessary to implement and analyze diverse functions. In this paper, we propose a facile flow rate control method by varying the permeability of chromatography
Droplet control through the use of light-induced thermocapillary effects has recently garnered attention due to its non-intrusive and multifunctional nature. An important issue in droplet control is the estimation of the thermocapillary force. The purpose of the present study is to estimate the thermocapillary force and propose empirical equations between the force and simply measurable key parameters such as droplet diameter and power of heat source. In addition, we aim to shift the droplet tra
A new, microfluidic polydiacetylene (PDA) sensor system based on the hydrodynamic focusing principle is developed. Narrow fluorescent bands are observed when the focused stream of a PDA solution contacts the sheath flows of cyclodextrin (CD) receptor molecules (see figure). The system allows for continuous and rapid monitoring of molecular recognition events.
Rational design of a hydrocarbon sensor that enables visual differentiation of saturated aliphatic hydrocarbons (SAHCs) is very difficult owing to the lack of useful functional groups that can interact with the sensor system. Here, we report a microbead embedded with polydiacetylene that undergoes faster swelling and faster blue-to-red color change in response to the hydrocarbons of shorter alkyl chains. Accordingly, visual differentiation among n-pentane, n-heptane, n-nonane, and n-undecane was
A microfluidic technique was employed to fabricate polydiacetylene (PDA)-embedded hydrogel microfibers. By taking advantage of calcium ion-induced insoluble hydrogel formation, supramolecularly assembled diacetylene (DA)-surfactant complexes were successfully immobilized in the calcium alginate fibers. Thus, instantaneous microfiber formation was observed when the core flow of DA supramolecules-containing alginate solution met the sheath flow of calcium ions. UV irradiation of the resulting fibe
The viscosity of biofluids can be used to acquire meaningful medical information on the conditions of a patient but has seldom been utilized in clinical practices owing to cumbersome measurement procedures and the need for large sample volumes. We present a colorimetric method to measure the viscosity of blood plasma using a paper-based viscometer developed in this study specifically for clinical diagnosis. The proposed analytical device consists of multilayered papers with fluid-loading, -mixin
Polymerizable supramolecular monomer vesicles are readily fabricated by employing a hydrodynamic focusing method on a microfluidic chip. The polymerized diacetylenene nanovesicles, generated using the microfluidic method, display an improved fluorescence property compared to those prepared by employing a conventional bulk method. The flexibility of the vesicle size control by manipulating the flow conditions is another significant feature of the new microfluidic approach.