[论文解读] An $^{27}$Al$^{+}$ quantum-logic clock with systematic uncertainty below $10^{-18}$
展示一个 27Al+ 量子逻辑时钟,总系统性不确定性为 9.4e-19 的稳定性为 1.2e-15/√τ,使用与 25Mg+ 的对称性冷却和改进的陷阱设计以接近 3D 基态运动。
We describe an optical atomic clock based on quantum-logic spectroscopy of the $^1$S$_0$ $\leftrightarrow$ $^3$P$_0$ transition in $^{27}$Al$^{+}$ with a systematic uncertainty of ${9.4 imes 10^{-19}}$ and a frequency stability of ${1.2 imes10^{-15}/\sqrtτ}$. A $^{25}$Mg$^{+}$ ion is simultaneously trapped with the $^{27}$Al$^{+}$ ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous $^{27}$Al$^{+}$ clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous $^{27}$Al$^{+}$ clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.
研究动机与目标
- 展示一个27Al+量子逻辑时钟,系统性不确定性低于1e-18。
- 量化并缓解主导系统偏移,如多余微运动和时间膨胀。
- 展示改进的阱设计,实现近似3D基态运动的冷却。
- 将时钟稳定性与参考的Yb晶格时钟进行表征。
- 讨论对基本常数和潜在SI秒重新定义路线图的影响。
提出的方法
- 对27Al+的1S0 <-> 3P0跃迁进行量子逻辑光谱学。
- 使用共捕获的25Mg+离子进行对冷却和读出。
- 基态冷却序列和降低阱驱动以降低 EMM。
- 两束相对相反的时钟光束,配合多普勒跟踪伺服以抵消一阶多普勒。
- 蒙特卡洛分析将 EMM 测量的不确定性传递到位移预算。
实验结果
研究问题
- RQ1在使用所述阱和冷却增强的情况下,27Al+量子逻辑时钟能实现的总分数频率不确定度是多少?
- RQ2限制不确定度的主导系统偏移是什么,如何量化和降低?
- RQ3实时微运动补偿对时间膨胀和与多普勒相关的位移有何影响?
- RQ4在较长平均时间内,时钟稳定性与参考的Yb晶格时钟相比如何?
- RQ5该装置能否在接近3D基态运动时钟操作以最小化多普勒偏移?
主要发现
- 总分数频率偏移为 Δν/ν = -9336.0(9.4)×10^-19,总系统性不确定性为 9.4×10^-19。
- 多余微运动对偏移贡献 -45.8(5.9)×10^-19。
- 黑体辐射贡献 -30.5(4.2)×10^-19。
- 二次 Zeeman 位移贡献 -9241.8(3.7)×10^-19。
- 惯性运动贡献 -17.3(2.9)×10^-19。
- 一阶多普勒和时钟激光斯塔克位移被约束为接近零,不确定性分别为2.2×10^-19和2.0×10^-19。