Skip to main content

Eun-Ah Park

Seoul National University · 医学

研究室紹介

Professor Eun-Ah Park's research lab specializes in diagnostic radiology and medical imaging, with a focus on optimizing computed tomography (CT) techniques for improved disease detection and characterization. The lab investigates advanced CT protocols—such as low-kilovoltage imaging, xenon ventilation CT, and 3D vascular anatomy analysis—to enhance image quality, reduce radiation dose, and improve diagnostic accuracy in pulmonary and cardiovascular diseases. Key research directions include quantitative and qualitative assessment of chronic obstructive pulmonary disease (COPD), coronary CT angiography, and venous thromboembolism. The lab also explores the integration of computer-aided detection (CAD) and multiplanar reconstruction techniques to support clinical decision-making in oncology and vascular imaging.

low-dose CTxenon ventilation CTcoronary CT angiography3D vascular anatomyradiation dose optimization

Research Overview

Papers
213
Total Citations
3,466
Papers (5y)
28
Primary Field
医学

Research Output Trend

Figures are computed from collected data and may differ slightly.

Publications per year (5y)
28total
2022
2023
2024
2025
2026
Citations per year (5y)
99total
20222023202420252026

Selected Papers

15
1
Article|103 citations·2010
Chronic Obstructive Pulmonary Disease: Quantitative and Visual Ventilation Pattern Analysis at Xenon Ventilation CT Performed by Using a Dual-Energy Technique
Eun‐Ah Park, Jin Mo Goo, Sang Joon Park, Hyun Ju Lee, Chang Hyun Lee, Chang Min Park, Chul‐Gyu Yoo, Jong Hyo Kim
SJR Q1Radiology

PURPOSE: To evaluate the potential of xenon ventilation computed tomography (CT) in the quantitative and visual analysis of chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS: This study was approved by the institutional review board. After informed consent was obtained, 32 patients with COPD underwent CT performed before the administration of xenon, two-phase xenon ventilation CT with wash-in (WI) and wash-out (WO) periods, and pulmonary function testing (PFT). For quantitative

Atomic and Molecular Physics, and OpticsPhysics and Astronomy
2
Article|64 citations·2012
Image quality of Adaptive Iterative Dose Reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection
Roh‐Eul Yoo, Eun‐Ah Park, Whal Lee, Hackjoon Shim, Yeo Koon Kim, Jin Wook Chung, Jai Hyung Park
International journal of cardiac imaging
Radiology, Nuclear Medicine and ImagingMedicine
3
Article|58 citations·2009
Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose
Kwang Nam Jin, Eun‐Ah Park, Cheong‐Il Shin, Whal Lee, Jin Wook Chung, Jai Hyung Park
International journal of cardiac imaging
Radiology, Nuclear Medicine and ImagingMedicine
4
Article|53 citations·2011
Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
Eun‐Ah Park, Whal Lee, Kwang Woo Kim, Kwang Gi Kim, Thomas Allmendinger, Jin Wook Chung, Jae Hyung Park
International journal of cardiac imaging
Radiology, Nuclear Medicine and ImagingMedicine
5
Article|50 citations·2009
The Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography
Eun‐Ah Park, Whal Lee, Jin-Hwa Kang, Yong Yin, Jin Wook Chung, Jae Hyung Park
SJR Q1Korean Journal of RadiologyOA

OBJECTIVE: This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. MATERIALS AND METHODS: We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effective mAs or 120 kVp and 500 effective mAs. The density measurements (image noise, vessel density, sign

Radiology, Nuclear Medicine and ImagingMedicine
6
Article|43 citations·2009
Efficacy of Computer-Aided Detection System and Thin-Slab Maximum Intensity Projection Technique in the Detection of Pulmonary Nodules in Patients With Resected Metastases
Eun‐Ah Park, Jin Mo Goo, Jeong Won Lee, Chang Hyun Kang, Hyun Ju Lee, Chang Hyun Lee, Chang Min Park, Ho Yun Lee, Jung-Gi Im
SJR Q1Investigative Radiology

In candidates for metastatectomy, reading with the aid of either CAD or MIP significantly improved the detection of malignant nodules compared with using thin-section CT alone.

Pulmonary and Respiratory MedicineMedicine
7
Article|38 citations·2011
Three-Dimensional Evaluation of the Anatomic Variations of the Femoral Vein and Popliteal Vein in Relation to the Accompanying Artery by Using CT Venography
Eun‐Ah Park, Jin Wook Chung, Whal Lee, Yong Yin, Jongwon Ha, Sang Joon Kim, Jae Hyung Park
SJR Q1Korean Journal of RadiologyOA

OBJECTIVE: We wanted to describe the three-dimensional (3D) anatomic variations of the femoral vein (FV) and popliteal vein (PV) in relation to the accompanying artery using CT venography. MATERIALS AND METHODS: We performed a retrospective review of 445 bilateral (890 limbs) lower limb CT venograms. After the 3D relationship between the FV and PV and accompanying artery was analyzed, the presence or absence of variation was determined and the observed variations were classified. In each patient

SurgeryMedicine
8
Article|36 citations·2009
The Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography
박은아, 강진화, 인용후, 정진욱, 박재형, 이활

Objective: This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. Materials and Methods: We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effective mAs or 120 kVp and 500 effective mAs. The density measurements (image noise, vessel density, sign

9
Article|36 citations·2016
Influence of Coronary Artery Diameter on Intracoronary Transluminal Attenuation Gradient During CT Angiography
Eun‐Ah Park, Whal Lee, Sang Joon Park, Yeo Koon Kim, Ho Young Hwang
SJR Q1JACC. Cardiovascular imaging
Radiology, Nuclear Medicine and ImagingMedicine
10
Article|32 citations·2008
EGFR gene copy number in adenocarcinoma of the lung by FISH analysis: Investigation of significantly related factors on CT, FDG-PET, and histopathology
Eun‐Ah Park, Hyun Ju Lee, Young Tae Kim, Chang Hyun Kang, Keon Wook Kang, Yoon Kyung Jeon, Jin Mo Goo, Chang Hyun Lee, Chang Min Park
SJR Q1Lung Cancer
Pulmonary and Respiratory MedicineMedicine
11
Article|31 citations·2010
Optimal Scan Timing and Intravenous Route for Contrast-Enhanced Computed Tomography in Patients After Fontan Operation
Eun‐Ah Park, Whal Lee, Se-Young Chung, Yong Yin, Jin Wook Chung, Jae Hyung Park
SJR Q3Journal of Computer Assisted Tomography

The optimal enhancement of the pulmonary arteries and Fontan tract can be achieved by a 3-minute-delay scan irrespective of the intravenous route location.

EpidemiologyMedicine
12
Article|31 citations·2007
Chronic-Stage Deep Vein Thrombosis of the Lower Extremities
Eun‐Ah Park, Whal Lee, Min Woo Lee, Sang-Il Choi, Hwan Jun Jae, Jin Wook Chung, Jai Hyung Park
SJR Q3Journal of Computer Assisted Tomography

Luminal obliteration, decreased caliber, fibrotic bands, ipsilateral muscle enlargement, and superficial collateral vein development are common CT findings in chronic DVT of the lower extremity.

Internal MedicineMedicine
13
Article|25 citations·2015
Effect of Papillary Muscles and Trabeculae on Left Ventricular Measurement Using Cardiovascular Magnetic Resonance Imaging in Patients with Hypertrophic Cardiomyopathy
Eun‐Ah Park, Whal Lee, Hyung‐Kwan Kim, Jin Wook Chung
SJR Q1Korean Journal of RadiologyOA

OBJECTIVE: To evaluate the influence of papillary muscles and trabeculae on left ventricular (LV) cardiovascular magnetic resonance (CMR) analysis using three methods of cavity delineation (classic or modified inclusion methods, and the exclusion method) in patients with hypertrophic cardiomyopathy (HCM). MATERIALS AND METHODS: This retrospective study included 20 consecutive HCM patients who underwent 1.5-T CMR imaging with short-axis cine stacks of the entire LV. LV measurements were performed

Cardiology and Cardiovascular MedicineMedicine
14
Article|23 citations·2004
Glomangiomatosis: magnetic resonance imaging findings in three cases
Eun‐Ah Park, Sung Hwan Hong, Ja‐Young Choi, Min Woo Lee, Heung‐Sik Kang
SJR Q2Skeletal Radiology
Pathology and Forensic MedicineMedicine
15
Article|22 citations·2015
Extent of late gadolinium enhancement at right ventricular insertion points in patients with hypertrophic cardiomyopathy: relation with diastolic dysfunction
Yinsu Zhu, Eun‐Ah Park, Whal Lee, Hyung‐Kwan Kim, A Jung Chu, Jin Wook Chung, Jae Hyung Park
SJR Q1European Radiology
Cardiology and Cardiovascular MedicineMedicine

Research Areas

Radiology, Nuclear Medicine and ImagingCardiology and Cardiovascular MedicineSurgeryPulmonary and Respiratory MedicineBiomedical EngineeringEpidemiology

Eun-Ah Parkの研究をNubintでさらに深く

この研究室の論文をアプリで開き、AIと共に読み、要約し、引用しましょう。