Jung-Mok Seo
Yonsei University · 工学
研究室紹介
Professor Jung-Mok Seo's research lab specializes in advanced functional materials for biomedical and microfluidic applications, focusing on the design of smart surfaces with tunable wettability, self-healing properties, and biofouling resistance. The lab develops innovative hydrogels and superamphiphobic/superhydrophobic materials for wound healing, tissue engineering, and point-of-care diagnostics, emphasizing mechanical durability, hemostasis, and antibacterial performance. Key research directions include stimuli-responsive surface engineering, droplet manipulation systems, and bioinspired materials inspired by nature, such as the pitcher plant. The lab integrates materials science, surface chemistry, and biomedical engineering to create next-generation medical devices with enhanced functionality and clinical translatability.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15Hydrogels are used in wound dressings because of their tissue-like softness and biocompatibility. However, the clinical translation of hydrogels remains challenging because of their long-term stability, water swellability, and poor tissue adhesiveness. Here, tannic acid (TA) is introduced into a double network (DN) hydrogel consisting of poly(vinyl alcohol) (PVA) and poly(acrylic acid) (PAA) to realize a tough, self-healable, nonswellable, conformally tissue-adhesive, hemostatic, and antibacteri
pitcher plant. LOIS presents a long-lasting, extreme liquid repellency against diverse liquids and biosubstances including cells, proteins, calcium, and bacteria. In addition, we confirmed mechanical durability against scratches and fixation force by simulating inevitable damages during surgical procedure ex vivo. The antibiofouling and anti-infection capability of LOIS were thoroughly investigated using an osteomyelitis femoral fracture model of rabbits. We envision that the LOIS with antibiofo
Herein, a droplet manipulation system with a superamphiphobic (SPO)-superamphiphilic (SPI) patterned polydimethylsiloxane (PDMS) substrate is developed for a multiplex bioassay from single-droplet samples. The SPO substrate is fabricated by sequential spraying of adhesive and fluorinated silica nanoparticles onto a PDMS substrate. It is subsequently subjected to oxygen plasma with a patterned mask to form SPI patterns. The SPO layer exhibits extreme liquid repellency with a high contact angle (>
We present a facile method to fabricate hydrophilic patterns in superhydrophobic Si nanowire (NW) arrays for guiding water droplets. The superhydrophobic Si NW arrays were obtained by simple dip-coating of dodecyltrichlorosilane (DTS). The water contact angles (CAs) of DTS-coated Si NW arrays drastically increased and saturated at the superhydrophobic regime (water CA ≥ 150°) as the lengths of NWs increased. The demonstrated superhydrophobic surfaces show an extreme water repellent property and
A switchable water-adhesive, super-hydrophobic nanowire surface is developed for the formation of functional stem cell spheroids. The sizes of hADSC spheroids are readily controllable on the surface. Our surface increases cell-cell and cell-matrix interaction, which improves viability and paracrine secretion of the spheroids. Accordingly, the hADSC spheroids produced on the surface exhibit significantly enhanced angiogenic efficacy.
Here, we developed a novel and facile method to control the local water adhesion force of a thin and stretchable superhydrophobic polydimethylsiloxane (PDMS) substrate with micro-pillar arrays that allows the individual manipulation of droplet motions including moving, merging and mixing. When a vacuum pressure was applied below the PDMS substrate, a local dimple structure was formed and the water adhesion force of structure was significantly changed owing to the dynamically varied pillar densit
Brain-machine interfaces (BMIs) that link the brain to a machine are promising for the treatment of neurological disorders through the bi-directional translation of neural information over extended periods. However, the longevity of such implanted devices remains limited by the deterioration of their signal sensitivity over time due to acute inflammation from insertion trauma and chronic inflammation caused by the foreign body reaction. To address this challenge, a lubricated surface is fabricat
A gas-driven ultrafast adhesion switching of water droplets on palladium-coated Si nanowire arrays is demonstrated. By regulating the gas-ambient between the atmosphere and H2 , the super-hydrophobic adhesion is repeatedly switched between water-repellent and water-adhesive. The capability of modulating the super-hydrophobic adhesion on a super-hydrophobic surface with a non-contact mode could be applicable to novel functional lab-on-a-chip platforms.
Electrical impedance biosensors are powerful and continuously being developed for various biological sensing applications. In this line, the sensitivity of impedance biosensors embedded with microfluidic technologies, such as sheath flow focusing, dielectrophoretic focusing, and interdigitated electrode arrays, can still be greatly improved. In particular, reagent consumption reduction and analysis time-shortening features can highly increase the analytical capabilities of such biosensors. Moreo
Wearable and implantable bioelectronics have received a great deal of interest since the need for personalized healthcare systems has arisen. Bioelectronics are designed to detect biological signals and apply medical treatments, thereby enabling patients to monitor and manage their health conditions. However, current bioelectronics lack long-term stability, biocompatibility, and functionality after implantation into the human body. In particular, the intrinsically different natures of the device
Major concerns in the development of wearable textile electronics are exposure to moisture and contamination. The exposure can cause electrical breakdown of the device and its interconnections, and thus continuous efforts have been made to fabricate textile electronics which are free from moisture and pollution. Herein, we developed a highly conductive and waterproof fiber with excellent electrical conductivity (0.11 Ω/cm) and mechanical stability for advanced interconnector components in wearab
Biophysical cues can potently direct a cell's or tissue's behavior. Cells interpret their biophysical surroundings, such as matrix stiffness or dynamic mechanical stimulation, through mechanotransduction. However, our understanding of the various aspects of mechanotransduction has been limited by the lack of proper analysis platforms capable of screening three-dimensional (3D) cellular behaviors in response to biophysical cues. Here, we developed a dynamic compression bioreactor to study the com
Superomniphobic surfaces showing extremely liquid-repellent properties have received a great amount of attention as they can be used in various industrial and biomedical applications. However, so far, the fabrication processes of these materials mostly have involved the coating of perfluorocarbons onto micro- and nanohierarchical structures of these surfaces, which inevitably causes environmental pollution, leading to health concerns. Herein, we developed a facile method to obtain flexible super
While a clear operating field during endoscopy is essential for accurate diagnosis and effective surgery, fogging or biofouling of the lens can cause loss of visibility during these procedures. Conventional cleaning methods such as the use of an irrigation unit, anti-fogging surfactant, or particle-based porous coatings infused with lubricants have been used but proven insufficient to prevent loss of visibility. Herein, a mechanically robust anti-fogging and anti-biofouling endoscope lens was de