Sung Hee Lim
Yonsei University · 医学
研究室紹介
Professor Sung Hee Lim's research lab specializes in the development of low-cost, portable, and highly sensitive chemical and biological sensing technologies, with a focus on colorimetric sensor arrays for medical and environmental applications. The lab pioneers innovative sensor systems that enable rapid, on-site detection of disease biomarkers, pathogens, and toxic substances through distinctive color changes in response to chemical or biological analytes. Key research directions include the detection of cancer biomarkers, volatile organic compounds from pathogenic bacteria, and metabolomic fingerprints in clinical samples such as blood cultures. The lab integrates materials science, analytical chemistry, and biomedical engineering to create practical diagnostic tools for early disease detection and point-of-care use.
Research Overview
Research Output Trend
Figures are computed from collected data and may differ slightly.
Selected Papers
15Introduction: Immune checkpoint inhibitors targeting programmed death protein 1 (PD-1) receptor and its ligand, PD-L1, have recently led to significant and durable improvements in the clinical outcomes of some types of cancers including lung cancer.Areas covered: Pembrolizumab was approved by the US FDA for the treatment of advanced or metastatic NSCLC whose disease has progressed after other treatments and with tumors that express PD-L1. In the phase I KEYNOTE-001 trial, the overall response ra
Molecular recognition of sugars and a practical method to detect and discriminate among a large number of such similar analytes remain substantial scientific challenges. We report here a low-cost, simple colorimetric sensor array capable of identification and quantification of sugars and related compounds. Fifteen different monosaccharides, disaccharides, and artificial sweeteners were differentiated without error in 80 trials. Limits of detection at pH 7.4 for glucose were <1 mM, which is below
BACKGROUND: Fibroblast growth factor receptor 1 (FGFR1) amplification is a potential driving oncogene in squamous cell cancer (SCC) of the lung. The current phase 2 study evaluated the efficacy and tolerability of dovitinib, an FGFR inhibitor, in patients with advanced SCC of the lung. METHODS: Patients with pretreated advanced SCC of the lung whose tumors demonstrated FGFR1 amplification of > 5 copies by fluorescence in situ hybridization were enrolled. Dovitinib at a dose of 500 mg was adminis
The development of a low-cost, simple colorimetric sensor array capable of the detection and identification of toxic gases is reported. This technology uses a disposable printed array of porous pigments in which metalloporphyrins and chemically-responsive dyes are immobilized in a porous matrix of organically modified siloxanes (ormosils) and printed on a porous membrane. The printing of the ormosil into the membrane is highly uniform and does not lessen the porosity of the membrane, as shown by
A colorimetric sensor array is a high-dimensional chemical sensor that is cheap, compact, disposable, robust, and easy to operate, making it a good candidate technology to detect pathogenic bacteria, especially potential bioterrorism agents like Yersinia pestis and Bacillus anthracis which feature on the Center for Disease Control and Prevention's list of potential biothreats. Here, a colorimetric sensor array was used to continuously monitor the volatile metabolites released by bacteria in soli
Sepsis is a medical emergency demanding early diagnosis and tailored antimicrobial therapy. Every hour of delay in initiating effective therapy measurably increases patient mortality. Blood culture is currently the reference standard for detecting bloodstream infection, a multistep process which may take one to several days. Here, we report a novel paradigm for earlier detection and the simultaneous identification of pathogens in spiked blood cultures by means of a metabolomic "fingerprint" of t
Clinical microbiology automation is currently limited by the lack of an in-plate culture identification system. Using an inexpensive, printed, disposable colorimetric sensor array (CSA) responsive to the volatiles emitted into plate headspace by microorganisms during growth, we report here that not only the presence but the species of bacteria growing in plate was identified before colonies are visible. In 1894 trials, 15 pathogenic bacterial species cultured on blood agar were identified with 9
The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different uri