아람 제이 찬 교수의 연구실은 미세유체역학 기반의 고성능 세포 내 물질 도입 기술과 생체 분석 기술을 핵심으로 연구를 전개하고 있습니다. 특히 관성 포지셔닝을 활용한 단일 입자 흐름 제어, 고속 세포 분리 및 분석, 그리고 유연하고 대량 생산 가능한 SERS 기반 생체 센서 기술 개발에 주력하고 있습니다. 이는 면역세포 치료, 유전자 편집, 암 치료 등 첨단 의료 응용에 기여할 수 있는 핵심 기반 기술입니다.
표시된 성과는 수집된 데이터 기준으로 산출되며, 일부 차이가 있을 수 있습니다.
A novel inertial focusing platform creates a single-stream microparticle train in a single-focal plane without sheath fluids and external forces, all in a high-throughput manner. The proposed design consists of a low-aspect-ratio straight channel interspersed with a series of constrictions in height arranged orthogonally, making use of inertial focusing and geometry-induced secondary flows. Focusing efficiency as high as 99.77% is demonstrated with throughput as high as 36 000 particles s(-1) fo
Correction for 'Continuous inertial microparticle and blood cell separation in straight channels with local microstructures' by Zhenlong Wu et al., Lab Chip, 2016, 16, 532-542.
Innate cell function can be artificially engineered and reprogrammed by introducing biomolecules, such as DNAs, RNAs, plasmid DNAs, proteins, or nanomaterials, into the cytosol or nucleus. This process of delivering exogenous cargos into living cells is referred to as intracellular delivery. For instance, clustered regularly interspaced short palindromic repeats (CRISPR)-Cas9 gene editing begins with internalizing Cas9 protein and guide RNA into cells, and chimeric antigen receptor-T (CAR-T) cel
Cell therapy and cellular engineering begin with internalizing synthetic biomolecules and functional nanomaterials into primary cells. Conventionally, electroporation, lipofection, or viral transduction has been used; however, these are limited by their cytotoxicity, low scalability, cost, and/or preparation complexity, especially in primary cells. Thus, a universal intracellular delivery method that outperforms the existing methods must be established. Here, we present a versatile intracellular
Fluid inertia has been used to position microparticles in confined channels because it leads to precise and predictable particle migration across streamlines in a high-throughput manner. To focus particles, typically two inertial effects have been employed: inertial migration of particles in combination with geometry-induced secondary flows. Still, the strong scaling of inertial effects with fluid velocity or channel flow rate have made it challenging to design inertial focusing systems for sing
Surface enhanced Raman scattering (SERS) is an analytical sensing method that provides label-free detection, molecularly specific information, and extremely high sensitivity. The Raman enhancement that makes this method attractive is mainly attributed to the local amplification of the incident electromagnetic field that occurs when a surface plasmon mode is excited at a metallic nanostructure. Here, we present a simple, cost effective method for creating flexible, large area SERS-active substrat
The introduction of nanomaterials into cells is an indispensable process for studies ranging from basic biology to clinical applications. To deliver foreign nanomaterials into living cells, traditionally endocytosis, viral and lipid nanocarriers or electroporation are mainly employed; however, they critically suffer from toxicity, inconsistent delivery, and low throughput and are time-consuming and labor-intensive processes. Here, we present a novel inertial microfluidic cell hydroporator capabl
In this work, a low power and robust electroactive microwell-based implantable drug delivery system, intended for use with autonomous microsystems, is presented. The device comprises of an upper silicon based structure in which the drug storage sites are defined and a lower electrically functionalized PDMS (polydimethylsiloxane) backing. The drug ejection mechanism developed here exploits localized electrokinetic effects to control both the release time and release rate of chemicals stored in in
Mechanical biomarkers associated with cytoskeletal structures have been reported as powerful label-free cell state identifiers. In order to measure cell mechanical properties, traditional biophysical (e.g., atomic force microscopy, micropipette aspiration, optical stretchers) and microfluidic approaches were mainly employed; however, they critically suffer from low-throughput, low-sensitivity, and/or time-consuming and labor-intensive processes, not allowing techniques to be practically used for
The successful intracellular delivery of exogenous macromolecules is crucial for a variety of applications ranging from basic biology to the clinic. However, traditional intracellular delivery methods such as those relying on viral/non-viral nanocarriers or physical membrane disruptions suffer from low throughput, toxicity, and inconsistent delivery performance and are time-consuming and/or labor-intensive. In this study, we developed a single-step hydrodynamic cell deformation-induced intracell
In recent nanobiotechnology developments, a wide variety of functional nanomaterials and engineered biomolecules have been created, and these have numerous applications in cell biology. For these nanomaterials to fulfill their promises completely, they must be able to reach their biological targets at the subcellular level and with a high level of specificity. Traditionally, either nanocarrier- or membrane disruption-based method has been used to deliver nanomaterials inside cells; however, thes
Whole-cell-based therapy has been extensively used as an effective disease treatment approach, and it has rapidly changed the therapeutic paradigm. To fully accommodate this shift, advances in genome modification and cell reprogramming methodologies are critical. Traditionally, molecular tools such as viral and polymer nanocarriers and electroporation have been the norm for internalizing external biomolecules into cells for cellular engineering. However, these approaches are not fully satisfacto
We report the development of two liquid waveguide based photonic elements for use in reconfigurable photonic systems. This work demonstrates the ability to couple light from a conventional optical fiber to an adaptable liquid-core/liquid-cladding waveguide and back again to an optical fiber(s) enabling us to take advantage of both liquid- and solid-state photonic modalities. We demonstrate and characterize the use of this fiber-in and fiber-out system as either an optical switch or signal attenu