北海道大学 · Engineering
토케시 마나부 교수의 연구실은 마이크로플루이딕스와 종이기반 분석 장치를 중심으로 초박막 유체 제어 및 초미량 물질 검출 기술을 개발하고 있습니다. 특히, 마이크로채널 내 연속 흐름을 이용한 화학 공정 통합, 이온 페어 추출을 통한 금속 이온 분석, 그리고 열렌즈 현미경을 활용한 초미량 분자 탐지 기술에 초점을 맞추고 있습니다. 또한, 비용 효율적이고 사용이 간편한 μPADs(마이크로플루이드릭스 종이 기반 분석 장치)를 통해 식품 및 환경 오염물질의 현장에서 신속한 모니터링을 실현하고자 합니다.
표시된 성과는 수집된 데이터 기준으로 산출되며, 일부 차이가 있을 수 있습니다.
A new design and construction methodology for integration of complicated chemical processing on a microchip was proposed. This methodology, continuous-flow chemical processing (CFCP), is based on a combination of microunit operations (MUOs) and a multiphase flow network. Chemical operations in microchannels, such as mixing, reaction, and extraction, were classified into several MUOs. The complete procedure for Co(II) wet analysis, including a chelating reaction, solvent extraction, and purificat
An ion-pair solvent extraction was performed in a microchannel fabricated in a quartz glass chip. the aqueous solution of Fe-bathophenanthrolinedisulfonic acid complex and the chloroform solution of tri-n-octylmethylammonium chloride were introduced into the microchannel, and a parallel two-phase laminar flow was formed. The ion-pair product extracted in chloroform was monitored by the thermal lens microscope. The ion-pair product was gradually extracted from aqueous solution into chloroform whe
The photothermal effect of an ultratrace amount of nonfluorescent molecules in liquid was determined by optimizing the optical arrangement for a thermal lens microscope. The optimized experimental setup could be determined from the evaluation of probing volume and the concentration of the sample solutions even when the expectation of the molecule number in the probing region was less than a single molecule. The minimum expectation, which is explained as being the time average, was 0.4 molecule o
Food and water contamination cause safety and health concerns to both animals and humans. Conventional methods for monitoring food and water contamination are often laborious and require highly skilled technicians to perform the measurements, making the quest for developing simpler and cost-effective techniques for rapid monitoring incessant. Since the pioneering works of Whitesides' group from 2007, interest has been strong in the development and application of microfluidic paper-based analytic
This paper describes a simple and instrument-free screen-printing method to fabricate hydrophilic channels by patterning polydimethylsiloxane (PDMS) onto chromatography paper. Clearly recognizable border lines were formed between hydrophilic and hydrophobic areas. The minimum width of the printed channel to deliver an aqueous sample was 600 μm, as obtained by this method. Fabricated microfluidic paper-based analytical devices (μPADs) were tested for several colorimetric assays of pH, glucose, an
We present a new rapid and easy-to-use immunoassay chip which we have named the immuno-pillar chip. It has hydrogel pillars, fabricated inside a microchannel, with many antibody molecules immobilized onto 1 µm diameter polystyrene beads. To evaluate the chip performance, we applied it to the sandwich assay of C-reactive protein (CRP), α-fetoprotein (AFP) and prostate-specific antigen (PSA), a cardiac and inflammation marker, tumors and prostate cancer markers, respectively. For detection of dise