Nam‐Young Kim
서울대학교 공과대학 · 공학
김남영 교수의 연구실은 생체 신호 감지 및 인공지능 기반 지능형 센서 시스템 개발에 초점을 맞추고 있습니다. 특히 고감도 레이저 레지온기반 생체센서, 전자피부(e-skin), 메모리 기반 인식 시스템 등 신축성 있고 재사용 가능한 유비쿼터스 센서 기술을 연구하며, 바이오센서, 인공지능 융합 센서, 나노소재 기반 생체 감지 플랫폼을 핵심 연구 분야로 삼고 있습니다. 특히 인간의 감각 기능을 모방한 지능형 센서 시스템과 생체 분석을 위한 고성능 레이저 레지온기반 센서 기술이 주요 성과입니다.
표시된 성과는 수집된 데이터 기준으로 산출되며, 일부 차이가 있을 수 있습니다.
Tremendous demands for sensitive and reliable label-free biosensors have stimulated intensive research into developing miniaturized radiofrequency resonators for a wide range of biomedical applications. Here, we report the development of a robust, reusable radiofrequency resonator based integrated passive device biosensor chip fabricated on a gallium arsenide substrate for the detection of glucose in water-glucose solutions and sera. As a result of the highly concentrated electromagnetic energy
Abstract Intelligent perception means that with the assistance of artificial intelligence (AI)‐motivated brain, flexible sensors achieve the ability of memory, learning, judgment, and reasoning about external information like the human brain. Due to the superiority of machine learning (ML) algorithms in data processing and intelligent recognition, intelligent perception systems possess the ability to match or even surpass human perception systems. However, the built‐in flexible sensors in these
A reusable robust radio frequency (RF) biosensor with a rectangular meandered line (RML) resonator on a gallium arsenide substrate by integrated passive device (IPD) technology was designed, fabricated and tested to enable the real-time identification of the glucose level in human serum. The air-bridge structure fabricated by an IPD technology was applied to the RML resonator to improve its sensitivity by increasing the magnitude of the return loss (S21). The resonance behaviour, based on S21 ch
Developing electronic skins (e-skins) that are comparable to or even beyond human tactile perception holds significant importance in advancing the process of intellectualization. In this context, a machine-learning-motivated micropyramid array bimodal (MAB) e-skin based on capacitive sensing is reported, which enables spatial mapping applications based on bimodal sensing (proximity and pressure) implemented via fringing and iontronic effects, such as contactless measurement of 3D objects and con
This research reveals the promising functionalization of graphene oxide (GrO)-glazed double-interdigitated capacitive (DIDC) biosensing platform to detect severe acute respiratory syndrome coronavirus (SARS-CoV-2) spike (S1) proteins with enhanced selectivity and rapid response. The DIDC bioactive surface consisting of Pt/Ti featured SiO<sub>2</sub> substrate was fabricated using GrO/EDC-NHS/anti-SARS-CoV-2 antibodies (Abs) which is having layer-by-layer interface self-assembly chemistry method.
The integrated "perception-memory" system is receiving increasing attention due to its crucial applications in humanoid robots, as well as in the simulation of the human retina and brain. Here, a Field Programmable Gate Array (FPGA) platform-boosted system that enables the sensing, recognition, and memory for human-computer interaction is reported by the combination of ultra-thin Ag/Al/Paster-based electronic tattoos (AAP) and Tantalum Oxide/Indium Gallium Zinc Oxide (Ta<sub>2</sub>O<sub>5</sub>
In this study, a high-sensitivity and low-hysteresis porous metal-insulator-metal-type capacitive humidity sensor is investigated using a functional polymer mixed with TiO2 microparticles. The humidity sensor consists of an optimally designed porous top electrode, a functional polymer humidity sensitive layer, a bottom electrode, and a glass substrate. The porous top electrode is designed to increase the contact area between the sensing layer and water vapor, leading to high sensitivity and quic
Abstract Recently, polymer materials have been at the forefront of other materials in building high‐performance flexible electronic skin (e‐skin) devices due to conspicuous advantages including excellent mechanical flexibility, good compatibility, and high plasticity. However, most research works just paid considerable attention and effort to the design, construction, and possible application of e‐skins that reproduce the tactile perception of the human skin sensory system. Compared with tactile
This article presents a high-sensitivity, quantified, linear, and mediator-free resonator-based microwave biosensor for glucose sensing application. The proposed biosensor comprises an air-bridge-type asymmetrical differential inductor (<i>L</i>) and a center-loaded circular finger-based inter-digital capacitor (<i>C</i>) fabricated on Gallium Arsenide (GaAs) substrate using advanced micro-fabrication technology. The intertwined asymmetrical differential inductor is used to achieve a high induct