Sung Hee Lim
성균관대학교 의과대학 · 의학
Sung Hee Lim 교수의 연구실은 주로 생체 분자인 당류, 독성 기체, 병원성 박테리아 등 다양한 생물학적 및 화학적 분석 대상의 정밀 감지과 정량을 위한 저비용·간편한 색채 센서 어레이 기술을 개발하고 있습니다. 특히 암 치료의 바이오마커로 활용 가능한 표적 치료 반응 예측 기술과 혈액 감염의 조기 진단을 위한 대사 프로파일링 기반 감지 기술에도 응용하고 있습니다. 이는 임상 진단의 빠른 전환과 생물위협 대응에 기여할 수 있는 혁신적 기술입니다.
표시된 성과는 수집된 데이터 기준으로 산출되며, 일부 차이가 있을 수 있습니다.
Introduction: Immune checkpoint inhibitors targeting programmed death protein 1 (PD-1) receptor and its ligand, PD-L1, have recently led to significant and durable improvements in the clinical outcomes of some types of cancers including lung cancer.Areas covered: Pembrolizumab was approved by the US FDA for the treatment of advanced or metastatic NSCLC whose disease has progressed after other treatments and with tumors that express PD-L1. In the phase I KEYNOTE-001 trial, the overall response ra
Molecular recognition of sugars and a practical method to detect and discriminate among a large number of such similar analytes remain substantial scientific challenges. We report here a low-cost, simple colorimetric sensor array capable of identification and quantification of sugars and related compounds. Fifteen different monosaccharides, disaccharides, and artificial sweeteners were differentiated without error in 80 trials. Limits of detection at pH 7.4 for glucose were <1 mM, which is below
Treatment with dovitinib demonstrated modest efficacy in patients with advanced SCC with FGFR1 amplification. Further studies to evaluate other biomarkers correlated with the efficacy of dovitinib in patients with SCC are warranted. Cancer 2016;122:3024-3031. © 2016 American Cancer Society.
The development of a low-cost, simple colorimetric sensor array capable of the detection and identification of toxic gases is reported. This technology uses a disposable printed array of porous pigments in which metalloporphyrins and chemically-responsive dyes are immobilized in a porous matrix of organically modified siloxanes (ormosils) and printed on a porous membrane. The printing of the ormosil into the membrane is highly uniform and does not lessen the porosity of the membrane, as shown by
A colorimetric sensor array is a high-dimensional chemical sensor that is cheap, compact, disposable, robust, and easy to operate, making it a good candidate technology to detect pathogenic bacteria, especially potential bioterrorism agents like Yersinia pestis and Bacillus anthracis which feature on the Center for Disease Control and Prevention's list of potential biothreats. Here, a colorimetric sensor array was used to continuously monitor the volatile metabolites released by bacteria in soli
Sepsis is a medical emergency demanding early diagnosis and tailored antimicrobial therapy. Every hour of delay in initiating effective therapy measurably increases patient mortality. Blood culture is currently the reference standard for detecting bloodstream infection, a multistep process which may take one to several days. Here, we report a novel paradigm for earlier detection and the simultaneous identification of pathogens in spiked blood cultures by means of a metabolomic "fingerprint" of t
Clinical microbiology automation is currently limited by the lack of an in-plate culture identification system. Using an inexpensive, printed, disposable colorimetric sensor array (CSA) responsive to the volatiles emitted into plate headspace by microorganisms during growth, we report here that not only the presence but the species of bacteria growing in plate was identified before colonies are visible. In 1894 trials, 15 pathogenic bacterial species cultured on blood agar were identified with 9
The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different uri