Naonori Hu 교수의 연구실은 박성기반 방사선 치료 기술인 보론 중성자 캡처 치료(BNCT)의 임상적 적용을 위한 핵심 기술 개발에 집중하고 있습니다. 특히 가속기 기반 중성자원 설계, 치료 계획 시스템의 정밀도 향상, 인체형 몰드에서의 선량 분포 최적화 등 임상 현장에서의 안전성과 효과성을 확보하는 데 중점을 두고 있습니다. 연구는 주로 중성자 선량 측정, 마이크로다이오미트릭 측정, 몬테카를로 시뮬레이션을 활용한 필터 및 콜리메이터 설계를 포함합니다.
표시된 성과는 수집된 데이터 기준으로 산출되며, 일부 차이가 있을 수 있습니다.
Boron neutron capture therapy (BNCT) for the treatment of unresectable, locally advanced, and recurrent carcinoma of the head and neck cancer has been approved by the Japanese government for reimbursement under the national health insurance as of June 2020. A new treatment planning system for clinical BNCT has been developed by Sumitomo Heavy Industries, Ltd. (Sumitomo), NeuCure® Dose Engine<sub>.</sub> To safely implement this system for clinical use, the simulated neutron flux and gamma ray do
The world’s first accelerator based epithermal neutron source for clinical boron neutron capture therapy (BNCT) was designed, developed, and commissioned between 2008 and 2010 by Sumitomo Heavy Industries in collaboration with Kyoto University at the Kyoto University Institute for Integrated Radiation and Nuclear Science. The accelerator system is cyclotron-based and accelerates a proton up to an energy of approximately 30 MeV. The proton strikes a beryllium target, which produces fast neutrons
Boron neutron capture therapy (BNCT) is an emerging radiation treatment modality, exhibiting the potential to selectively destroy cancer cells. Currently, BNCT is conducted using a nuclear reactor. However, the future trend is to move toward an accelerator-based system for use in hospital environments. A typical BNCT radiation field has several different types of radiation. The beam quality should be quantified to accurately determine the dose to be delivered to the target. This study utilized a
The Kansai BNCT Medical Center has a cyclotron based epithermal neutron source for clinical Boron Neutron Capture Therapy. The system accelerates a proton to an energy of 30 MeV which strikes a beryllium target producing fast neutrons which are moderated down to epithermal neutrons for BNCT use. While clinical studies in the past have shown BNCT to be highly effective for malignant melanoma of the skin, to apply BNCT for superficial lesions using this system it is necessary to shift the thermal
In June 2020, the Japanese government approved boron neutron capture therapy for the treatment of head and neck cancer. The treatment is usually performed in a single fraction, with the neutron irradiation time being approximately 30-60 min. As neutrons scatter in air and loses its intensity, it is preferable to bring the patient as close to the beam port as possible to shorten the irradiation time. However, this can be a challenge, especially for patients with head and neck cancer, as the shoul
A neutron filtration system for an accelerator-based BNCT system was investigated using Monte Carlo simulation. The proposed filter design significantly improved the dose distribution for the treatment of deep targets in the brain.
The PHITS model for clinical BNCT for the whole-body region was validated, and the OAR doses were then evaluated. Clinicians and medical physicists should know that the out-of-field radiation increases the OAR dose in the whole-body region.
A neutron beam for boron neutron capture therapy (BNCT) of deep-seated tumours is designed to maintain a high flux of epithermal neutrons, while keeping the thermal and fast neutron component as low as possible. These neutrons (thermal and fast) have a high relative biological effectiveness in comparison with high energy photon beams used for conventional X-ray radiotherapy. In the past, neutrons for the purpose of BNCT were generated using nuclear reactors. However, there are various challenges
The myOSLD system was characterized using an accelerator system designed for clinical BNCT. The experimental measurements confirmed the OSLD achieved similar, if not superior to, the currently utilized dosimetry system for routine QA of an accelerator-based BNCT system. The OSLD system would be a suitable replacement for the current TLD system for performing routine QA of gamma ray dose measurement in a BNCT irradiation field.
A stoichiometric CT number calibration method using the newly developed Nakao20 model was applied to BNCT dose calculation. The results indicate the importance of calibrating the CT number to elemental composition for each individual CT scanner for the purpose of BNCT dose calculation along with the consideration of heterogeneity of the material composition inside the defined region of interest.
Boron neutron capture therapy for recurrent head and neck cancer has been approved as an insurance covered treatment in Japan since June 2020. The Kansai BNCT Medical Center has installed the NeuCure® BNCT system developed by Sumitomo Heavy Industries. This system utilises a beryllium target with a 30 MeV proton beam to generate neutrons. To date, the center has treated over 300 patients and the system is also used for quality control and fundamental research experiments. Information on the stab
Abstract In June 2020, the Japanese government approved boron neutron capture therapy for the treatment of head and neck cancer. The treatment is usually performed in a single fraction, with the neutron irradiation time being approximately 30–60 minutes. As neutrons scatter in air and loses its intensity, it is preferable to bring the patient close to the beam port as possible to shorten the irradiation time. However, this can be a challenge, especially for patients with head and neck cancer, as