TL;DR

Introduces rotation-XMPI, a three-beam XMPI approach, enabling 4D reconstruction of laser-melt pools at detector-rate limits and achieving ~25,000 reconstructed volumes per second, a 250-fold speed-up over prior operando LPBF imaging.

ABSTRACT

Advancing additive manufacturing, e.g., laser powder-bed fusion (LPBF), requires resolving rapid processes such as melt-pool dynamics and keyhole evolution in 4D (3D + time). Operando X-ray tomography is a state-of-the-art approach for 4D characterization, but its temporal resolution is fundamentally constrained by the sample rotation speed, limiting achievable 4D imaging rates and preventing the resolution of these fast phenomena. Here we present rotation-enabled X-ray Multi-Projection Imaging (rotation-XMPI), which captures three angularly resolved projections per time step and thereby decouples temporal resolution from the sample rotation speed. Combined with a self-supervised deep-learning reconstruction framework for multi-angle inputs, rotation-XMPI enables high-fidelity 4D imaging at unprecedented speed. We demonstrate the approach in an operando alumina laser-remelting experiment at MAX IV using three beamlets combined with 25 Hz sample rotation. Rotation-XMPI resolves melt-pool morphology and keyhole evolution; in contrast, conventional and limited-angle tomography remain rotation-limited, and motion blur prevents resolving these dynamics. Overall, rotation-XMPI delivers a 250-fold increase relative to state-of-the-art melt-pool imaging, effectively achieving 25,000 reconstructed volumes per second. This method establishes a practical route to scalable ultrafast 4D imaging for additive manufacturing and other materials processes.

Motivation & Objective

  • Resolve rapid 4D melt-pool dynamics (3D + time) during laser remelting in LPBF.
  • Decouple temporal resolution from sample rotation by using multi-projection XMPI.
  • Develop a self-supervised 4D reconstruction framework adapted to rotation-XMPI data.
  • Compare rotation-XMPI with conventional tomography and limited-angle STRT to quantify gains in temporal and spatial fidelity.

Proposed method

  • Use rotation-enabled X-ray Multi-Projection Imaging (rotation-XMPI) with three synchronized X-ray beamlets and detectors.
  • Acquire three simultaneous projections per time step at 25 kHz detector frame rate while rotating the sample at 25 Hz.
  • Preprocess projections for detector artifacts, alignment, brightness normalization, denoising, and Paganin phase retrieval.
  • Adapt the X-Hexplane 4D reconstruction framework for rotation-XMPI data to jointly reconstruct the 4D phase-shift field.
  • Evaluate reconstruction fidelity against static references using normalized cross-correlation and robustness checks.
Fig. 1: Acquisition setup and reconstruction results of laser remelting. a Schematic of the XMPI data-acquisition setup. Three X-ray beamlets are shown in blue and the laser in red. The sample is mounted on a rotating holder. b Photograph of the sample mounted on the holder (background grayed out) a
Fig. 1: Acquisition setup and reconstruction results of laser remelting. a Schematic of the XMPI data-acquisition setup. Three X-ray beamlets are shown in blue and the laser in red. The sample is mounted on a rotating holder. b Photograph of the sample mounted on the holder (background grayed out) a

Experimental results

Research questions

  • RQ1Can rotation-XMPI decouple temporal resolution from rotation speed to resolve fast melt-pool dynamics in LPBF?
  • RQ2How does rotation-XMPI compare to conventional operando tomography and STRT in terms of temporal and spatial fidelity for melt-pool evolution?
  • RQ3What is the achievable 4D imaging rate and spatial/temporal resolution when using three simultaneous projections with self-supervised reconstruction?

Key findings

  • Rotation-XMPI achieves 25,000 reconstructed volumes per second with 40 μs temporal spacing.
  • Reconstructed volume: 200 × 200 × 16 voxels at 4 × 4 × 4 μm^3 voxel size, over 700 time steps spanning 28 ms.
  • 3-beam XMPI with ~47.7° maximum inter-beam angle effectively decouples timing from rotation, enabling single-time-step reconstructions.
  • Compared to conventional tomography and STRT, rotation-XMPI provides higher fidelity and resolves melt-pool morphology and keyhole dynamics without pronounced motion blur.
  • Demonstrates 250-fold increase in reconstructed-volume rate relative to prior operando LPBF tomography (from rotation-limited to detector-limited timing).
  • Validation shows consistent reconstruction quality across odd/even frame subsets and reasonable agreement with static references.
Fig. 2: Comparison of imaging and reconstruction approaches. a,b Schematics of rotation-XMPI and limited-angle tomography in the sample’s frame of reference. Circled numbers denote the detector positions, and colors encode acquisition times (red/blue/green); the center depicts schematic melt-pool po
Fig. 2: Comparison of imaging and reconstruction approaches. a,b Schematics of rotation-XMPI and limited-angle tomography in the sample’s frame of reference. Circled numbers denote the detector positions, and colors encode acquisition times (red/blue/green); the center depicts schematic melt-pool po