Skip to main content
QUICK REVIEW

[Paper Review] A Comparison of Amputee and Able-Bodied Inter-Subject Variability in Myoelectric Control

Evan Campbell, Jason S. Chang|arXiv (Cornell University)|Mar 7, 2020
Muscle activation and electromyography studiesEngineering13 references10 citations
TL;DR

This study compares myoelectric control patterns between amputee and able-bodied individuals using EMG data from 20 intact-limbed and 10 trans-radial amputee subjects performing 38 common gestures. Using unsupervised clustering and linear classification, it found that amputee and able-bodied EMG patterns form distinct clusters, with amputees showing significantly higher inter-subject variability, indicating that able-bodied data alone is insufficient for developing clinically viable cross-user myoelectric prostheses.

ABSTRACT

Despite decades of research and development of pattern recognition approaches, the clinical usability of myoelectriccontrolled prostheses is still limited. One of the main issues is the high inter-subject variability that necessitates long and frequent user-specific training. Cross-user models present an opportunity to improve clinical viability of myoelectric control systems by leveraging existing data to shorten training. However, due to the difficulty of obtaining large sets of data from amputee populations, data from intact-limbed subjects are often supplemented when building cross-user models; which may not translate well to clinical usability. In this preliminary study, the differences between intact-limbed and amputee cross-user electromyography (EMG) patterns were examined. Previously collected EMG data from 20 intact limbed and 10 amputee subjects for different wrist, finger, and grasping gestures were analysed. Results using unsupervised clustering showed that amputees were consistently grouped into a different cluster than intact-limbed subjects and that additional clustering into more subgroups found larger differences between amputees than able-bodied subjects. Furthermore, a simple linear classifier was able to discriminate between able-bodied and amputee subjects using EMG from multiple gestures with 90% accuracy. These results suggest that using able-bodied subject data alone may be insufficient to capture the necessary inter-subject variance when designing cross-user myoelectric control systems for prosthesis control.

Motivation & Objective

  • To investigate whether myoelectric control patterns differ significantly between amputee and able-bodied individuals.
  • To assess the feasibility of using able-bodied data to train cross-user myoelectric control systems for amputees.
  • To quantify inter-subject variability in EMG patterns across both populations using clustering and classification techniques.
  • To determine whether amputee EMG patterns can be grouped into homogeneous subgroups or exhibit higher variability than able-bodied subjects.

Proposed method

  • Collected surface EMG data from 20 intact-limbed and 10 trans-radial amputee subjects using 12 Delsys Trigno electrodes at 2000 Hz sampling rate.
  • Pre-processed data using a Hampel filter to remove 50 Hz power-line interference and corrected erroneous motion labels with a generalized likelihood ratio algorithm.
  • Extracted Hudgins' time-domain EMG features (MAV, WL, ZC, SSC) from 200 ms overlapping windows with 100 ms increments.
  • Applied hierarchical cluster analysis (HCA) with average linkage and Euclidean distance to identify subgroups based on EMG feature patterns.
  • Used a linear classifier to discriminate between amputee and able-bodied subjects based on EMG features across all gestures.
  • Evaluated classification accuracy using 10-fold cross-validation and reported mean, min, and max accuracy across subjects and gestures.

Experimental results

Research questions

  • RQ1Do myoelectric control patterns from amputee and able-bodied individuals form distinct clusters in feature space?
  • RQ2Is inter-subject variability in EMG patterns higher among amputees than among able-bodied individuals?
  • RQ3Can a linear classifier accurately distinguish between amputee and able-bodied subjects based on EMG signals from multiple gestures?
  • RQ4Do clinical characteristics such as years since amputation, remaining forearm length, or cause of amputation correlate with EMG pattern differences?
  • RQ5Can unsupervised clustering identify meaningful subgroups within the amputee population that reflect underlying physiological or behavioral differences?

Key findings

  • Unsupervised hierarchical clustering identified two distinct subgroups: one comprising all 20 able-bodied subjects and another comprising all 10 amputee subjects, indicating fundamental differences in EMG patterns.
  • When clustering was extended to 3–5 subgroups, the amputee group was further partitioned into subgroups, while the able-bodied group remained largely intact, indicating higher inter-subject variability in amputees.
  • A linear classifier achieved 90% accuracy in distinguishing amputee from able-bodied subjects using EMG features from multiple gestures, with a mean accuracy of 66% across all subjects and motions (chance level: 66%).
  • The amputee subgroup with the highest inter-subject variability included subjects with prior experience using myoelectric prostheses, suggesting that learning and adaptation may contribute to EMG pattern differences.
  • Subject A4 (amputee) exhibited the highest amplitude-based feature values (MAV, WL) but the lowest complexity-based features (ZC, SSC), with high variance possibly due to noise or inconsistent contractions.
  • Cluster 1D (4 amputees) showed the lowest amplitude-based features but the highest complexity and frequency-based features, and included subjects with prior myoelectric prosthesis use, indicating potential behavioral or neuromuscular adaptation effects.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.