TL;DR

This paper proposes a modified sequence domain impedance definition that accounts for mirror frequency effects—frequency components shifted by twice the fundamental frequency—ensuring equivalence with the established dq-domain impedance model for stability analysis. The key contribution is proving that the Generalized Nyquist Criterion yields identical stability estimates in both domains when using the modified sequence matrix, resolving prior ambiguity in impedance modeling for non-Mirror Frequency Decoupled (non-MFD) systems.

ABSTRACT

Representations of AC power systems by frequency dependent impedance equivalents is an emerging technique in the dynamic analysis of power systems including power electronic converters. The technique has been applied for decades in DC-power systems, and it was recently adopted to map the impedances in AC systems. Most of the work on AC systems can be categorized in two approaches. One is the analysis of the system in the extit{dq}-domain, whereas the other applies harmonic linearization in the phase domain through symmetric components. Impedance models based on analytical calculations, numerical simulation and experimental studies have been previously developed and verified in both domains independently. The authors of previous studies discuss the advantages and disadvantages of each domain separately, but neither a rigorous comparison nor an attempt to bridge them has been conducted. The present paper attempts to close this gap by deriving the mathematical formulation that shows the equivalence between the extit{dq}-domain and the sequence domain impedances. A modified form of the sequence domain impedance matrix is proposed, and with this definition the stability estimates obtained with the Generalized Nyquist Criterion (GNC) become equivalent in both domains. The second contribution of the paper is the definition of a extit{Mirror Frequency Decoupled} (MFD) system. The analysis of MFD systems is less complex than that of non-MFD systems because the positive and negative sequences are decoupled. This paper shows that if a system is incorrectly assumed to be MFD, this will lead to an erroneous or ambiguous estimation of the equivalent impedance.

Motivation & Objective

  • Address the lack of rigorous comparison between dq-domain and sequence-domain impedance models in AC power electronic systems.
  • Resolve the ambiguity in the original sequence domain impedance definition, which depends on injection type and system configuration.
  • Establish a mathematically equivalent framework between the dq-domain and a modified sequence domain impedance representation.
  • Define Mirror Frequency Decoupled (MFD) systems as a sufficient condition to eliminate mirror frequency coupling and simplify analysis.
  • Demonstrate that stability estimates via the Generalized Nyquist Criterion are equivalent across both domains when using the modified sequence definition.

Proposed method

  • Derive a modified 2x2 sequence domain impedance matrix that explicitly accounts for mirror frequency effects by shifting positive and negative sequence components by twice the fundamental frequency.
  • Formulate the mathematical transformation between the modified sequence domain impedance matrix and the standard dq-domain impedance matrix, proving eigenvalue preservation and equivalence under the Generalized Nyquist Criterion.
  • Introduce the concept of Mirror Frequency Decoupled (MFD) systems, where the positive and negative sequence components are decoupled, simplifying impedance matrix structure.
  • Use ideal series and shunt injection models to derive relationships between source and load subsystems, validating the modified definition under both injection types.
  • Verify the theoretical derivations through numeric simulations, comparing stability predictions and impedance matrix structures across both domains.
  • Demonstrate that the dq-domain impedance matrix can be obtained directly from single measurements without matrix inversion when both subsystems are MFD.

Experimental results

Research questions

  • RQ1How can the sequence domain impedance model be modified to ensure equivalence with the dq-domain impedance model in stability analysis?
  • RQ2What is the impact of mirror frequency effects on the accuracy of sequence domain impedance modeling, and how can they be formally accounted for?
  • RQ3Under what conditions is the original sequence domain impedance definition ambiguous or incorrect, and how does this ambiguity depend on injection type?
  • RQ4What is the role of Mirror Frequency Decoupled (MFD) systems in simplifying impedance modeling and ensuring consistency between domains?
  • RQ5Can the Generalized Nyquist Criterion yield equivalent stability estimates in both the modified sequence and dq domains, and under what conditions?

Key findings

  • The modified sequence domain impedance matrix accounts for mirror frequency effects by shifting positive and negative sequence components by twice the fundamental frequency, resolving prior inconsistencies.
  • The modified sequence domain impedance matrix is mathematically equivalent to the standard dq-domain impedance matrix under a linear transformation that preserves eigenvalues and stability predictions via the Generalized Nyquist Criterion.
  • For Mirror Frequency Decoupled (MFD) systems, the modified sequence domain impedance matrix becomes diagonal, and the dq-domain matrix becomes skew-symmetric, simplifying analysis.
  • The original sequence domain impedance definition is ambiguous in general cases, as it depends on injection type (shunt vs. series), and source state variables appear in load impedance expressions.
  • When one subsystem is MFD, the original sequence domain impedance becomes independent of injection type, though source state variables still influence load impedance expressions.
  • The dq-domain impedance matrix can be directly obtained from a single measurement without matrix inversion when both subsystems are MFD, improving practical applicability.