Skip to main content
QUICK REVIEW

[Paper Review] A Uniform Type Ia Supernova Distance Ladder with the Zwicky Transient Facility: Absolute Calibration Based on the Tip of the Red Giant Branch (TRGB) Method

Suhail Dhawan, A. Goobar|arXiv (Cornell University)|Mar 8, 2022
Gamma-ray bursts and supernovaePhysics and Astronomy1 citations
TL;DR

This paper proposes a uniform Type Ia supernova distance ladder using the Zwicky Transient Facility (ZTF) to calibrate supernova luminosities via the Tip of the Red Giant Branch (TRGB) method, minimizing host-galaxy and photometric calibration biases. Using TRGB distances to SN 2021rhu in NGC7814 and a volume-limited ZTF Hubble flow sample, it derives H₀ = 76.94 ± 6.4 km s⁻¹ Mpc⁻¹, demonstrating a path toward a 1.8% precision measurement to resolve the Hubble tension.

ABSTRACT

The current Cepheid-calibrated distance ladder measurement of $H_0$ is reported to be in tension with the values inferred from the cosmic microwave background (CMB), assuming standard cosmology. However, some tip of the red giant branch (TRGB) estimates report $H_0$ in better agreement with the CMB. Hence, it is critical to reduce systematic uncertainties in local measurements to understand the Hubble tension. In this paper, we propose a uniform distance ladder between the second and third rungs, combining SNe~Ia observed by the Zwicky Transient Facility (ZTF) with a TRGB calibration of their absolute luminosity. A large, volume-limited sample of both calibrator and Hubble flow SNe~Ia from the \emph{same} survey minimizes two of the largest sources of systematics: host-galaxy bias and non-uniform photometric calibration. We present results from a pilot study using existing TRGB distance to the host galaxy of ZTF SN~Ia SN 2021rhu (aka ZTF21abiuvdk) in NGC7814. Combining the ZTF calibrator with a volume-limited sample from the first data release of ZTF Hubble flow SNe~Ia, we infer $H_0 = 76.94 \pm 6.4\, { m km}\,{ m s^{-1}}\,{ m Mpc^{-1}}$, an $8.3 \%$ measurement. The error budget is dominated by the single object calibrating the SN~Ia luminosity in this pilot study. However, the ZTF sample includes already five other SNe~Ia within $\sim$ 20 Mpc for which TRGB distances can be obtained with HST. Finally, we present the prospects of building this distance ladder out to 80 Mpc with JWST observations of more than one hundred ZTF SNe~Ia.

Motivation & Objective

  • To reduce systematic uncertainties in local H₀ measurements by constructing a uniform distance ladder using a single survey.
  • To minimize host-galaxy bias and photometric calibration inconsistencies by using a volume-limited sample of SNe Ia from the same survey.
  • To calibrate Type Ia supernova absolute luminosities using the TRGB method, which is less sensitive to host environment than Cepheid variables.
  • To enable a precise, independent measurement of H₀ to test the Hubble tension within the standard cosmological model.
  • To lay the foundation for extending the distance ladder to 80 Mpc using JWST observations of over 100 ZTF SNe Ia.

Proposed method

  • Utilizes the Zwicky Transient Facility (ZTF) to obtain a volume-limited sample of both calibrator and Hubble flow SNe Ia in the same photometric system.
  • Employs the Tip of the Red Giant Branch (TRGB) method to determine absolute distances to host galaxies of SNe Ia, using the well-understood luminosity of the TRGB as a standard candle.
  • Calibrates the absolute magnitude of SNe Ia using TRGB distances to SN 2021rhu in NGC7814, which is located at a distance of 20.5 Mpc.
  • Combines the TRGB-calibrated SN Ia luminosity with a volume-limited sample of 133 Hubble flow SNe Ia from ZTF’s first data release to infer H₀.
  • Projects future extension of the ladder to 80 Mpc using JWST to obtain TRGB distances to more than 100 ZTF SNe Ia within that range.
  • Reduces systematic errors by leveraging a single, untargeted survey for both calibrator and Hubble flow samples, minimizing cross-calibration and environmental biases.

Experimental results

Research questions

  • RQ1Can a uniform distance ladder be constructed using SNe Ia from a single survey to reduce systematic uncertainties in H₀ measurements?
  • RQ2To what extent does using the TRGB method instead of Cepheids reduce host-environment bias in SN Ia luminosity calibration?
  • RQ3What precision in H₀ can be achieved using a ZTF-based TRGB-calibrated distance ladder with current and future data?
  • RQ4How do improvements in TRGB zero-point calibration and additional anchor galaxies affect the final H₀ uncertainty?
  • RQ5Can this method resolve the Hubble tension by achieving sub-2% precision in H₀?

Key findings

  • The pilot study yields H₀ = 76.94 ± 6.4 km s⁻¹ Mpc⁻¹, corresponding to an 8.3% measurement precision, using TRGB distance to SN 2021rhu in NGC7814 as the calibrator.
  • The current error budget is dominated by the uncertainty in the single calibrator SN Ia, highlighting the need for additional TRGB-calibrated SNe Ia in the ZTF sample.
  • The ZTF survey already includes five other SNe Ia within ∼20 Mpc for which HST-based TRGB distances can be obtained, enabling future calibration improvements.
  • The method enables a projected H₀ precision of ∼1.8% with current TRGB zero-point uncertainty, sufficient for an independent test of the Hubble tension.
  • With future TRGB calibrations from multiple anchor galaxies and improved photometric zero points, the method could achieve ∼1.3% precision in H₀.
  • The use of a single survey for both calibrator and Hubble flow SNe Ia minimizes cross-calibration and host-environment biases, significantly reducing systematic errors.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.