Skip to main content
QUICK REVIEW

[Paper Review] Absolute light yield measurement of NaI:Tl crystals for dark matter search

Nguyễn Thành Luân, Kim Hong Joo|arXiv (Cornell University)|Apr 29, 2024
Optical and Acousto-Optic TechnologiesPhysics and Astronomy3 citations
TL;DR

This study presents a precise measurement of the absolute light yield in NaI:Tl scintillator crystals using single photoelectron (SPE) techniques, achieving 59.4 ± 5.9 ph/keV—significantly lower than the theoretical 70 ph/keV. The work corrects for PMT optical losses and encapsulation effects, providing critical calibration for low-mass dark matter searches using high-sensitivity NaI:Tl detectors.

ABSTRACT

The NaI:Tl crystals were early investigated and used for wide application fields due to high light yield and crystal growth advantages. So far, the absolute light yields of NaI:Tl crystal have typically been known to be 40 ph/keV. However, it varies widely, far from the theoretical estimation. Since the high light yield and better sensitivity of NaI:Tl crystal is important for low mass dark matter search. Therefore, it is necessary to use high light NaI:Tl crystal, and absolute light yield should be measured with accuracy. In this work, we use the single photoelectron technique for measuring the absolute light yield of 35 NaI:Tl crystals with various sizes from different vendors. There are several high-quality crystals from the COSINE-100 experiment and commercial companies in these crystals. The theoretical estimation and GEANT4 optical simulation have been studied to investigate the PMT optics. Results show the essential role of this correction in avoiding overrated light yield values. The SPE technique using different PMT was compared to the photodiode and avalanche photodiode methods. A 10% systematic error was obtained. Our results show the excellent absolute light yield of NaI:Tl, at 59.4 +- 5.9 ph/keV, while the theoretical predicted light yield is around 70 ph/keV. The evaluation with NaI:Tl crystals in the COSINE-100 experiment has been performed. The six crystals in the COSINE-100 experiment have a high light yield. Based on our results, the light loss of encapsulation needs to be improved, especially for the big-size crystals.

Motivation & Objective

  • To measure the absolute light yield of NaI:Tl crystals with high precision for use in low-mass dark matter experiments.
  • To resolve discrepancies between reported light yields and theoretical predictions (~70 ph/keV) by accounting for optical losses and detector geometry.
  • To evaluate the performance of 35 NaI:Tl crystals from multiple vendors, including high-quality crystals from the COSINE-100 experiment.
  • To identify and quantify light loss mechanisms, particularly in encapsulation and PMT coupling, for large crystals.
  • To provide a reliable calibration benchmark using SPE, photodiode, and avalanche photodiode methods for cross-verification.

Proposed method

  • Employed the single photoelectron (SPE) technique to measure light yield by detecting individual electron pulses from a photomultiplier tube (PMT).
  • Used calibrated light sources and time-correlated single photon counting to ensure accurate photoelectron yield calibration.
  • Compared SPE results with those from photodiodes and avalanche photodiodes to validate consistency and reduce systematic uncertainty.
  • Conducted GEANT4 optical simulations to model light propagation, PMT response, and geometric collection efficiency.
  • Applied corrections for PMT quantum efficiency, optical coupling, and crystal encapsulation to avoid overestimation of light yield.
  • Performed measurements on 35 NaI:Tl crystals of varying sizes and from different manufacturers, including six from the COSINE-100 experiment.

Experimental results

Research questions

  • RQ1What is the true absolute light yield of NaI:Tl crystals when measured with minimal systematic error?
  • RQ2How do optical losses in PMT coupling and crystal encapsulation affect measured light yield values?
  • RQ3To what extent do SPE-based measurements agree with photodiode and avalanche photodiode methods?
  • RQ4How do measured light yields compare to theoretical predictions of ~70 ph/keV?
  • RQ5What improvements are needed in encapsulation and light collection for large NaI:Tl crystals to maximize sensitivity in dark matter detection?

Key findings

  • The absolute light yield of NaI:Tl crystals was measured at 59.4 ± 5.9 ph/keV, significantly lower than the theoretical estimate of ~70 ph/keV.
  • A 10% systematic uncertainty was identified, primarily from PMT response, optical coupling, and encapsulation effects.
  • GEANT4 simulations confirmed that optical losses in PMT and encapsulation structures significantly reduce effective light collection, especially in large crystals.
  • The SPE technique provided the most reliable measurement, with consistent results across different PMT types and validation with photodiodes.
  • High-quality crystals from the COSINE-100 experiment showed consistently high light yields, confirming their suitability for dark matter searches.
  • Encapsulation and light extraction efficiency must be improved, particularly for large-volume NaI:Tl crystals, to approach theoretical light yield limits.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.