Skip to main content
QUICK REVIEW

[Paper Review] Accuracy of the Epic Sepsis Prediction Model in a Regional Health System

Tellen D. Bennett, Seth Russell|arXiv (Cornell University)|Feb 19, 2019
Sepsis Diagnosis and TreatmentMedicine2 references5 citations
TL;DR

This study evaluates the Epic Sepsis Prediction Model (ESPM) in a five-hospital regional health system, comparing its sepsis prediction accuracy against the existing Early Warning Score (EWS) system. The ESPM, a machine learning model using EHR data, demonstrated superior performance with an AUC of 0.73 versus EWS's 0.62, showing higher positive predictive value, recall, and overall accuracy in identifying sepsis early in hospitalization.

ABSTRACT

Interest in an electronic health record-based computational model that can accurately predict a patient's risk of sepsis at a given point in time has grown rapidly in the last several years. Like other EHR vendors, the Epic Systems Corporation has developed a proprietary sepsis prediction model (ESPM). Epic developed the model using data from three health systems and penalized logistic regression. Demographic, comorbidity, vital sign, laboratory, medication, and procedural variables contribute to the model. The objective of this project was to compare the predictive performance of the ESPM with a regional health system's current Early Warning Score-based sepsis detection program.

Motivation & Objective

  • To assess the predictive performance of the Epic Sepsis Prediction Model (ESPM) in a real-world regional health system setting.
  • To compare the ESPM’s accuracy in sepsis detection against the institution’s existing EWS-based sepsis detection program.
  • To evaluate the timing and clinical relevance of ESPM alerts relative to standard clinical markers like lactate levels.
  • To determine whether the ESPM improves early sepsis identification compared to current clinical practices.

Proposed method

  • Retrospective cohort study using inpatient data from five UCHealth hospitals between June 1, 2017, and October 20, 2017.
  • The ESPM was automatically calculated every two hours using EHR data, including demographics, vital signs, labs, medications, and comorbidities.
  • The EWS was calculated every four hours and manually documented by bedside nurses, using a score range of 0–21.
  • Comorbidities were defined using the ICD-10 CCS10 classification system via publicly available software.
  • Model performance was evaluated using standard metrics: AUC, positive predictive value, recall, negative predictive value, F1-score, and accuracy.
  • The primary outcome was any ICD-10 sepsis diagnosis code from a proprietary Vizient benchmarking codeset.

Experimental results

Research questions

  • RQ1How does the predictive accuracy of the Epic Sepsis Prediction Model (ESPM) compare to the existing EWS-based sepsis detection system in a regional health system?
  • RQ2At what point in the hospital course does the ESPM first reach a clinically relevant threshold (≥5) for sepsis prediction?
  • RQ3How does the timing of ESPM alerts compare to key clinical markers such as lactate measurement?
  • RQ4What is the performance of the ESPM in identifying patients who later develop sepsis, particularly in terms of positive predictive value and recall?

Key findings

  • The ESPM achieved an area under the receiver operating characteristic curve (AUC) of 0.73, significantly outperforming the EWS, which had an AUC of 0.62.
  • The ESPM demonstrated a positive predictive value of 0.44 compared to 0.33 for the EWS, indicating better precision in identifying true sepsis cases.
  • The ESPM had a recall (sensitivity) of 0.66 versus 0.61 for the EWS, showing improved detection of patients who developed sepsis.
  • The ESPM achieved an accuracy of 0.78, compared to 0.64 for the EWS, indicating better overall classification performance.
  • The median time to first ESPM alert of ≥5 was 7 hours after admission, and it reached this threshold a median of 7 hours after the first lactate was drawn (IQR 4–22).
  • Patients with sepsis had significantly higher median ESPM scores (66) than those without sepsis (40), and the highest ESPM values occurred earlier in the hospital course than EWS values.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.