Skip to main content
QUICK REVIEW

[Paper Review] An End-to-end Approach to Semantic Segmentation with 3D CNN and Posterior-CRF in Medical Images

Shuai Chen, Marleen de Bruijne|arXiv (Cornell University)|Nov 8, 2018
AI in cancer detectionComputer Science7 references8 citations
TL;DR

This paper proposes Posterior-CRF, an end-to-end deep learning framework that integrates a 3D fully connected Conditional Random Field (CRF) with a 3D U-Net for medical image semantic segmentation. Instead of using raw intensity values, Posterior-CRF applies CRF to the CNN’s posterior probability maps, enabling joint optimization of CNN and CRF parameters. It achieves state-of-the-art performance on white matter hyperintensities segmentation, outperforming both standard U-Net and prior end-to-end CRF methods.

ABSTRACT

Fully-connected Conditional Random Field (CRF) is often used as post-processing to refine voxel classification results by encouraging spatial coherence. In this paper, we propose a new end-to-end training method called Posterior-CRF. In contrast with previous approaches which use the original image intensity in the CRF, our approach applies 3D, fully connected CRF to the posterior probabilities from a CNN and optimizes both CNN and CRF together. The experiments on white matter hyperintensities segmentation demonstrate that our method outperforms CNN, post-processing CRF and different end-to-end training CRF approaches.

Motivation & Objective

  • To address the instability and sensitivity of intensity-based CRF post-processing in noisy medical images.
  • To overcome limitations of existing end-to-end CRF methods that rely on raw intensity features and require manual tuning of CRF parameters.
  • To improve spatial coherence and segmentation accuracy by leveraging high-quality feature maps from a trained CNN in the CRF inference.
  • To enable joint optimization of CNN and CRF parameters through a unified training pipeline.
  • To demonstrate superior performance on white matter hyperintensities segmentation in FLAIR MRI scans.

Proposed method

  • Posterior-CRF replaces intensity-based features in the CRF with posterior probability maps from the final layer of a 3D U-Net.
  • The method uses a fully connected CRF with unary potentials derived from CNN output probabilities and pairwise potentials based on spatial and feature distances.
  • The CRF parameters (e.g., θα, θβ, θγ, ω) are jointly optimized during end-to-end training with the CNN.
  • The pairwise potential combines a spatial-similarity kernel and a feature-similarity kernel, where features are now the CNN’s predicted class probabilities.
  • Mean field inference is applied on the posterior probability maps to refine voxel-wise predictions while enforcing spatial consistency.
  • The framework is trained using categorical cross-entropy loss and optimized via backpropagation through both CNN and CRF components.

Experimental results

Research questions

  • RQ1Can replacing intensity features with learned posterior probabilities in a CRF improve segmentation robustness and accuracy in medical imaging?
  • RQ2Does end-to-end joint optimization of CNN and CRF parameters lead to better performance than post-processing CRF or intensity-based CRF training?
  • RQ3How does the use of high-level feature maps from a 3D U-Net affect CRF inference stability and generalization in noisy medical images?
  • RQ4Can the need for manual hyperparameter tuning of CRF parameters be eliminated by training them jointly with the CNN?
  • RQ5How does Posterior-CRF compare to baseline U-Net and other CRF-based methods in terms of Dice score, Hausdorff distance, and false positive/negative rates?

Key findings

  • Posterior-CRF achieved a Dice similarity coefficient (DSC) of 0.747 ± 0.064 on the WMH 2017 dataset, significantly outperforming the baseline U-Net (0.683 ± 0.068) and other CRF methods.
  • The method achieved the lowest average volume difference (AVD) of 21.80% ± 5.92, indicating superior volumetric accuracy compared to other approaches.
  • Posterior-CRF reduced the number of false positives (FP) to 3387 ± 507.41, showing better control over over-segmentation than U-Net and Post-CRF post-processing.
  • It maintained a reasonable Hausdorff distance (H95) of 5.513 mm ± 2.818, outperforming Spatial-CRF and showing balanced performance across metrics.
  • Visual comparisons confirmed that Posterior-CRF produced the most accurate and visually coherent segmentations, with fewer false positives and better preservation of lesion structures.
  • The method eliminated the need for manual CRF hyperparameter tuning by jointly learning all CRF parameters during end-to-end training.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.