[Paper Review] Analysis of bio-electro-chemical signals from passive sweat-based wearable electro-impedance spectroscopy (EIS) towards assessing blood glucose modulations

Devangsingh Sankhala, Madhavi Pali|arXiv (Cornell University)|Apr 5, 2021
Advanced Sensor and Energy Harvesting MaterialsEngineering6 citations
TL;DR

This study presents a low-power, wearable electro-impedance spectroscopy (EIS) system with ultra-sensitive flexible biosensors for continuous, non-invasive glucose monitoring via passive sweat collection. Using ratiometric DFT calibration and an auto-regressive model, the system achieved stable 8-hour glucose detection in 20 healthy subjects with <1.25% inter-device error and high sensitivity across 5–200 mg/dL glucose concentrations.

ABSTRACT

There has been a recent tremendous interest in label-free detection of biomarkers which is a critical enabler of point-of-need diagnostics. A low-power, small form factor, multiplexed wearable system is proposed for continuous detection of glucose in passively expressed sweat using electrochemical impedance spectroscopy (EIS) measurement. The wearable EIS system consists of a sensing analog front end integrated with low-volume (1-5 $\\mu$L) ultra-sensitive flexible biosensors. A passive sweat sensor was designed to integrate a glucose oxidase electrochemical system on active semiconducting material. The non-faradaic EIS response of the biosensor was used to calibrate the analog front end response using ratiometric Discrete Fourier Transform (DFT) for a shorter measurement time. In this work, a stringent assessment of a continuous glucose sensing platform is performed in a bottom-up approach, going from the biosensor to the system to the interaction with a human subject. The active semiconductor-based biosensors are dosed with glucose concentrations ranging from 5-200 mg/dL and detection is performed using the analog front end. In addition, a detailed analysis of battery life and performance of a wearable EIS system is discussed to define a figure of merit for an optimally integrated design. Moreover, a continuous glucose detection test is performed on a healthy human subject cohort to investigate the stability of the sensor-system mechanism for an 8-hour period, and a time-series-based, auto-regressive (AR) model was created for the system.

Motivation & Objective

  • To develop a low-power, wearable EIS platform for continuous, non-invasive glucose monitoring using passive sweat collection.
  • To address challenges in signal stability and noise in low-volume biosensing by implementing ratiometric DFT calibration for improved accuracy.
  • To validate the system’s performance in real-world conditions using a human cohort over an 8-hour period.
  • To establish a figure of merit for system integration by analyzing battery life and performance trade-offs.
  • To demonstrate the feasibility of using time-series modeling (auto-regressive model) for continuous glucose trend prediction from EIS data.

Proposed method

  • Employed a passive sweat-based biosensor functionalized with glucose oxidase on a semiconductor substrate to enable non-faradaic EIS response.
  • Integrated a low-volume (1–5 µL) ultra-sensitive flexible biosensor with an analog front end using ADuCM350 for AC voltage application (10 mV, 100 Hz).
  • Applied ratiometric Discrete Fourier Transform (DFT) to calibrate the analog front end response, reducing systematic offset and improving signal-to-noise ratio.
  • Used time-division multiplexing to enable multi-channel operation with minimal power consumption.
  • Implemented a Bluetooth Low Energy (BLE) chip-set for real-time data transmission to a mobile application.
  • Integrated temperature and relative humidity (RH) sensing (HDC1080) and power management (BQ24040) for autonomous operation.

Experimental results

Research questions

  • RQ1Can a wearable EIS system achieve stable, continuous glucose monitoring in passive sweat over an 8-hour period with minimal inter-device variability?
  • RQ2How does ratiometric DFT calibration reduce systematic offset and improve signal accuracy in low-volume biosensing?
  • RQ3To what extent can an auto-regressive (AR) model predict glucose trends from time-series EIS data compared to interpolated sweat glucose measurements?
  • RQ4What is the impact of noise and error on battery life and system performance in a wearable EIS platform?
  • RQ5How does the system’s figure of merit for integration balance sensitivity, power efficiency, and measurement duration?

Key findings

  • The system demonstrated a systematic negative offset of 50 Ω (−1.25%) in impedance calibration, with inter-device variability of 50 Ω across three devices at 100 Hz.
  • Inter-channel variability was measured at a peak of 150 Ω across four channels, indicating consistent multi-channel performance.
  • The biosensor showed a detectable EIS response across glucose concentrations from 5 to 200 mg/dL in synthetic and human sweat, confirming sensitivity across the clinically relevant range.
  • In a cohort of 20 healthy subjects, continuous on-body measurements were successfully recorded every minute for 8 hours without physical exertion or sweat induction.
  • The auto-regressive (AR) model effectively captured glucose trend dynamics, enabling time-series prediction that correlated with interpolated sweat glucose values.
  • The system achieved stable performance with low power consumption, and the figure of merit analysis defined optimal trade-offs between sensitivity, battery life, and measurement duration.