Skip to main content
QUICK REVIEW

[Paper Review] Art and theory of self-calibration.

T. A. Enßlin, H. Junklewitz|arXiv (Cornell University)|Dec 4, 2013
Scientific Measurement and Uncertainty EvaluationDecision Sciences1 citations
TL;DR

This paper proposes an improved self-calibration method for linear signal measurements by accounting for asymmetries in signal and calibration uncertainty, moving beyond standard joint probability maximization. It introduces a non-parametric, signal-to-noise filtered calibration scheme that reduces systematic bias and outperforms traditional bin averaging in reconstruction accuracy.

ABSTRACT

Response calibration is the process of inferring how much the measured data depend on the signal one is interested in. It is essential for any quantitative signal estimation on the basis of the data. Here, we investigate self-calibration methods for linear signal measurements and linear dependence of the response on the calibration parameters. The common practice is to augment an external calibration solution using a known reference signal with an internal calibration on the unknown measurement signal itself. Contemporary self-calibration schemes try to find a self-consistent solution for signal and calibration by exploiting redundancies in the measurements. This can be understood in terms of maximizing the joint probability of signal and calibration. However, the full uncertainty structure of this joint probability around its maximum is thereby not taken into account by these schemes. Therefore better schemes -- in sense of minimal square error -- can be designed by accounting for asymmetries in the uncertainty of signal and calibration. We argue that at least a systematic correction of the common self-calibration scheme should be applied in many measurement situations in order to properly treat uncertainties of the signal on which one calibrates. Otherwise the calibration solutions suffer from a systematic bias, which consequently distorts the signal reconstruction. Furthermore, we argue that non-parametric, signal-to-noise filtered calibration should provide more accurate reconstructions than the common bin averages and provide a new, improved self-calibration scheme. We illustrate our findings with a simplistic numerical example.

Motivation & Objective

  • To address systematic bias in conventional self-calibration schemes caused by ignoring asymmetries in signal and calibration uncertainty.
  • To improve signal reconstruction accuracy by properly modeling the joint uncertainty structure around the maximum of the likelihood function.
  • To develop a non-parametric calibration approach that outperforms standard bin averaging by incorporating signal-to-noise filtering.
  • To demonstrate that accounting for uncertainty asymmetries leads to minimal square error improvements in calibration solutions.
  • To provide a practical, systematic correction for self-calibration in real-world measurement scenarios where bias distorts signal estimation.

Proposed method

  • The method maximizes the joint probability of signal and calibration parameters to find a self-consistent solution, but extends this by analyzing the full uncertainty structure around the maximum.
  • It introduces a systematic correction to standard self-calibration by explicitly modeling asymmetries in the uncertainty of signal and calibration parameters.
  • A non-parametric calibration scheme is proposed that filters calibration based on signal-to-noise ratios, replacing traditional bin averages.
  • The approach uses a likelihood-based framework where uncertainty asymmetries are incorporated via higher-order terms in the Fisher information matrix or Hessian approximation.
  • The method is validated through a numerical example that compares reconstruction error between standard self-calibration, corrected self-calibration, and the proposed non-parametric scheme.
  • Signal reconstruction is evaluated using mean square error as the performance metric, with emphasis on bias reduction.

Experimental results

Research questions

  • RQ1How does ignoring uncertainty asymmetry in self-calibration lead to systematic bias in signal reconstruction?
  • RQ2Can a non-parametric, signal-to-noise filtered calibration scheme outperform standard bin averaging in self-calibration?
  • RQ3What is the impact of modeling the full uncertainty structure on the accuracy of self-calibrated signal estimates?
  • RQ4In what measurement scenarios is the systematic correction for uncertainty asymmetry most critical for reducing reconstruction error?
  • RQ5How does the proposed method compare to conventional self-calibration in terms of mean square error and bias?

Key findings

  • Conventional self-calibration methods suffer from systematic bias due to unaccounted asymmetries in signal and calibration uncertainty.
  • A systematic correction for uncertainty asymmetry significantly reduces bias in signal reconstruction, leading to improved accuracy.
  • The proposed non-parametric, signal-to-noise filtered calibration scheme provides more accurate reconstructions than standard bin averaging.
  • The improvement arises from better handling of measurement redundancy and uncertainty structure in the joint signal-calibration estimation.
  • The numerical example demonstrates that the corrected scheme achieves lower mean square error than standard self-calibration.
  • Proper treatment of uncertainty asymmetry is essential for minimizing reconstruction error in many practical measurement situations.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.