[Paper Review] Autocorrelation bias still exists in fMRI results
This study evaluates temporal autocorrelation modeling in three major fMRI software packages—AFNI, FSL, and SPM—using 10 datasets across resting-state and task-based scans. It finds that FSL and SPM exhibit higher false positive rates and less effective pre-whitening than AFNI, with SPM introducing negative autocorrelations in long TR scans and FSL failing to remove substantial noise autocorrelation, especially under low-design-frequency assumptions.
Given the recent trend towards validating the neuroimaging statistical methods, we compared the most popular functional magnetic resonance imaging (fMRI) analysis softwares: AFNI, FSL and SPM, with regard to temporal autocorrelation modelling. We used both resting state and task-based fMRI data, altogether 10 datasets containing 780 scans corresponding to different scanning sequences and different subject populations. In analyses of each fMRI scan we considered different assumed experimental designs, as well as different spatial smoothing levels and different detrending options. For data used as null data the use of FSL and SPM resulted in much higher false positive rates than the use of AFNI. On the other hand, due to SPM modelling temporal autocorrelation in the least flexible way, it can introduce negative autocorrelations during pre-whitening for scans with long repetition times. For one dataset we observed a big loss of sensitivity when SPM was used. Interestingly, because pre-whitening in FSL and SPM does not remove a substantial part of the temporal autocorrelation in the noise, we observed a relationship that the lower the assumed experimental design frequency, the more likely it was to observe significant activation. Though temporal autocorrelation modelling in AFNI was not perfect, its performance was much higher than the performance of temporal autocorrelation modelling in FSL and SPM. FSL and SPM could improve their autocorrelation modelling approaches for example adopting a noise model similar to the one used by AFNI.
Motivation & Objective
- To assess the accuracy of temporal autocorrelation modeling across AFNI, FSL, and SPM in fMRI analysis.
- To investigate how different experimental designs, smoothing levels, and detrending methods affect false positive rates.
- To evaluate the impact of repetition time (TR) on autocorrelation modeling, particularly in SPM’s pre-whitening procedure.
- To compare the sensitivity and specificity of activation detection across software tools under identical data conditions.
- To identify shortcomings in current fMRI software that may lead to inflated Type I error rates or reduced statistical power.
Proposed method
- Compared AFNI, FSL, and SPM using 10 fMRI datasets (780 scans) from diverse sequences and subject groups.
- Applied multiple experimental designs, spatial smoothing levels, and detrending options to assess robustness.
- Used null data to evaluate false positive rates across software packages under identical preprocessing and modeling conditions.
- Analyzed pre-whitening performance in SPM and FSL to detect residual or artificially introduced autocorrelation.
- Evaluated sensitivity loss in activation detection, particularly in long TR scans where SPM’s modeling was least flexible.
- Quantified the relationship between assumed design frequency and significance rates, especially in FSL and SPM.
Experimental results
Research questions
- RQ1How do AFNI, FSL, and SPM compare in modeling temporal autocorrelation in fMRI data?
- RQ2What is the impact of repetition time (TR) on autocorrelation modeling, particularly in SPM’s pre-whitening process?
- RQ3How does the assumed experimental design frequency affect false positive detection rates in FSL and SPM?
- RQ4To what extent does pre-whitening in FSL and SPM remove residual temporal autocorrelation in noise?
- RQ5Why does SPM show a significant loss of sensitivity in one dataset, and is this linked to its autocorrelation modeling?
Key findings
- FSL and SPM produced significantly higher false positive rates than AFNI when using null data, indicating poorer control of Type I error.
- SPM introduced negative autocorrelations during pre-whitening in scans with long repetition times, likely due to inflexible modeling of the noise structure.
- A strong relationship was observed between lower assumed experimental design frequency and increased likelihood of detecting significant activation in FSL and SPM, due to incomplete removal of temporal autocorrelation.
- AFNI’s autocorrelation modeling, while not perfect, outperformed both FSL and SPM in maintaining statistical validity and reducing false positives.
- FSL and SPM failed to remove a substantial portion of temporal autocorrelation in the noise, especially under low-design-frequency assumptions.
- The study suggests that FSL and SPM could improve their autocorrelation modeling by adopting a noise model similar to AFNI’s, which better accounts for temporal dependencies.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.