Skip to main content
QUICK REVIEW

[Paper Review] Automated detection and quantification of COVID-19 airspace disease on chest radiographs: A novel approach achieving radiologist-level performance using a CNN trained on digital reconstructed radiographs (DRRs) from CT-based ground-truth

Eduardo Jose Mortani Barbosa, Warren B. Gefter|arXiv (Cornell University)|Aug 13, 2020
COVID-19 diagnosis using AIMedicine28 references5 citations
TL;DR

This study presents a deep learning approach using a CNN trained on digitally reconstructed radiographs (DRRs) derived from CT-based ground-truth to detect and quantify COVID-19-related airspace disease on chest X-rays (CXR). The method achieves radiologist-level accuracy, with a mean absolute error of 9.56–9.78% and correlation of 0.78–0.81 between predicted and ground-truth disease burden.

ABSTRACT

Purpose: To leverage volumetric quantification of airspace disease (AD) derived from a superior modality (CT) serving as ground truth, projected onto digitally reconstructed radiographs (DRRs) to: 1) train a convolutional neural network to quantify airspace disease on paired CXRs; and 2) compare the DRR-trained CNN to expert human readers in the CXR evaluation of patients with confirmed COVID-19. Materials and Methods: We retrospectively selected a cohort of 86 COVID-19 patients (with positive RT-PCR), from March-May 2020 at a tertiary hospital in the northeastern USA, who underwent chest CT and CXR within 48 hrs. The ground truth volumetric percentage of COVID-19 related AD (POv) was established by manual AD segmentation on CT. The resulting 3D masks were projected into 2D anterior-posterior digitally reconstructed radiographs (DRR) to compute area-based AD percentage (POa). A convolutional neural network (CNN) was trained with DRR images generated from a larger-scale CT dataset of COVID-19 and non-COVID-19 patients, automatically segmenting lungs, AD and quantifying POa on CXR. CNN POa results were compared to POa quantified on CXR by two expert readers and to the POv ground-truth, by computing correlations and mean absolute errors. Results: Bootstrap mean absolute error (MAE) and correlations between POa and POv were 11.98% [11.05%-12.47%] and 0.77 [0.70-0.82] for average of expert readers, and 9.56%-9.78% [8.83%-10.22%] and 0.78-0.81 [0.73-0.85] for the CNN, respectively. Conclusion: Our CNN trained with DRR using CT-derived airspace quantification achieved expert radiologist level of accuracy in the quantification of airspace disease on CXR, in patients with positive RT-PCR for COVID-19.

Motivation & Objective

  • To develop a method for accurate quantification of COVID-19-related airspace disease (AD) on chest radiographs (CXR) using deep learning.
  • To leverage volumetric AD segmentation from chest CT as ground-truth, projected into 2D DRRs for training.
  • To train a convolutional neural network (CNN) on DRRs to predict area-based AD percentage (POa) on CXR.
  • To compare the CNN’s performance against expert radiologists in detecting and quantifying AD on CXR.
  • To establish a clinically viable, automated tool for monitoring disease progression in confirmed COVID-19 patients using standard CXR.

Proposed method

  • Acquired a retrospective cohort of 86 confirmed COVID-19 patients with paired CT and CXR within 48 hours.
  • Performed manual 3D segmentation of airspace disease (AD) on CT scans to establish ground-truth volumetric percentage (POv).
  • Projected the 3D AD masks from CT onto 2D anterior-posterior DRRs to compute area-based AD percentage (POa) as a surrogate for CXR.
  • Trained a convolutional neural network (CNN) on DRR images generated from a larger CT dataset of both COVID-19 and non-COVID-19 patients.
  • The CNN was optimized to automatically segment lungs and AD, and to output POa on CXR.
  • Evaluated the CNN’s performance by comparing its POa predictions to both the CT-based ground-truth (POv) and to POa measured by two expert radiologists.

Experimental results

Research questions

  • RQ1Can a CNN trained on DRRs derived from CT-based ground-truth achieve accurate quantification of airspace disease on CXR?
  • RQ2How does the performance of the DRR-trained CNN compare to expert radiologists in measuring AD burden on CXR?
  • RQ3To what extent does the use of CT-derived volumetric segmentation as ground-truth improve the accuracy of CXR-based disease quantification?
  • RQ4Can the DRR projection method effectively simulate CXR appearance while preserving disease burden information for training?
  • RQ5Is the CNN’s performance robust enough to match radiologist-level accuracy in clinical evaluation of COVID-19-related lung involvement?

Key findings

  • The CNN achieved a bootstrap mean absolute error (MAE) of 9.56–9.78% when comparing predicted POa to the CT-based ground-truth (POv).
  • The CNN demonstrated a correlation of 0.78–0.81 between predicted POa and POv, indicating strong agreement with ground-truth.
  • The average of two expert readers achieved a MAE of 11.98% [11.05%–12.47%] and a correlation of 0.77 [0.70–0.82] with POv.
  • The CNN’s performance was statistically comparable to expert radiologists, with lower MAE and slightly higher correlation.
  • The DRR-based training approach enabled the CNN to generalize effectively to real CXR images despite being trained on CT-derived projections.
  • The method successfully transferred high-precision volumetric CT segmentation to 2D CXR, enabling automated, accurate disease quantification.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.