Skip to main content
QUICK REVIEW

[Paper Review] Automated lung segmentation from CT images of normal and COVID-19 pneumonia patients

Faeze Gholamiankhah, Samaneh Mostafapour|arXiv (Cornell University)|Apr 5, 2021
COVID-19 diagnosis using AIMedicine10 citations
TL;DR

This study proposes a deep learning-based residual neural network for automated lung segmentation in CT scans of both normal and COVID-19 pneumonia patients. Trained on 1,200 confirmed COVID-19 cases with manually/semi-automatically generated masks, the model achieved a Dice Similarity Coefficient (DSC) of 0.980 for normal subjects and 0.971 for COVID-19 patients, demonstrating high accuracy and robustness in segmenting lungs despite disease-induced abnormalities.

ABSTRACT

Automated semantic image segmentation is an essential step in quantitative image analysis and disease diagnosis. This study investigates the performance of a deep learning-based model for lung segmentation from CT images for normal and COVID-19 patients. Chest CT images and corresponding lung masks of 1200 confirmed COVID-19 cases were used for training a residual neural network. The reference lung masks were generated through semi-automated/manual segmentation of the CT images. The performance of the model was evaluated on two distinct external test datasets including 120 normal and COVID-19 subjects, and the results of these groups were compared to each other. Different evaluation metrics such as dice coefficient (DSC), mean absolute error (MAE), relative mean HU difference, and relative volume difference were calculated to assess the accuracy of the predicted lung masks. The proposed deep learning method achieved DSC of 0.980 and 0.971 for normal and COVID-19 subjects, respectively, demonstrating significant overlap between predicted and reference lung masks. Moreover, MAEs of 0.037 HU and 0.061 HU, relative mean HU difference of -2.679% and -4.403%, and relative volume difference of 2.405% and 5.928% were obtained for normal and COVID-19 subjects, respectively. The comparable performance in lung segmentation of the normal and COVID-19 patients indicates the accuracy of the model for the identification of the lung tissue in the presence of the COVID-19 induced infections (though slightly better performance was observed for normal patients). The promising results achieved by the proposed deep learning-based model demonstrated its reliability in COVID-19 lung segmentation. This prerequisite step would lead to a more efficient and robust pneumonia lesion analysis.

Motivation & Objective

  • To develop a reliable automated lung segmentation method for CT images of both normal and COVID-19 pneumonia patients.
  • To evaluate model performance on diverse patient populations, including those with severe lung involvement due to COVID-19.
  • To establish a robust preprocessing step for quantitative analysis of lung lesions in pulmonary diseases.
  • To compare segmentation accuracy between normal and COVID-19-affected lungs using multiple quantitative metrics.
  • To support downstream applications such as disease progression monitoring and treatment response assessment.

Proposed method

  • A residual neural network (ResNet) was trained on 1,200 confirmed COVID-19 CT scans with corresponding reference lung masks.
  • Reference lung masks were generated via semi-automated and manual segmentation to ensure high-quality ground truth.
  • The model was evaluated on two independent external test datasets: 120 normal and 120 COVID-19 patients.
  • Performance was assessed using standard metrics: Dice Similarity Coefficient (DSC), mean absolute error (MAE), relative mean Hounsfield Unit (HU) difference, and relative volume difference.
  • The network architecture leveraged skip connections to improve gradient flow and training stability in deep learning.
  • Data augmentation and normalization techniques were applied to enhance model generalization across diverse scan intensities and anatomical variations.

Experimental results

Research questions

  • RQ1Can a deep learning model achieve high-accuracy lung segmentation in CT scans of patients with severe COVID-19 pneumonia?
  • RQ2How does model performance on COVID-19-affected lungs compare to that on normal lungs?
  • RQ3To what extent does the presence of pulmonary infiltrates and ground-glass opacities in COVID-19 patients affect segmentation accuracy?
  • RQ4Is the model robust enough to maintain high performance across diverse patient demographics and scan protocols?
  • RQ5Can automated lung segmentation serve as a reliable foundation for subsequent quantitative analysis of lung lesions in pneumonia?

Key findings

  • The model achieved a Dice Similarity Coefficient (DSC) of 0.980 for normal subjects, indicating near-perfect overlap with reference lung masks.
  • For COVID-19 patients, the DSC was 0.971, demonstrating strong segmentation performance even in the presence of extensive lung involvement.
  • Mean absolute error (MAE) was 0.037 HU for normal subjects and 0.061 HU for COVID-19 patients, reflecting high intensity accuracy.
  • The relative mean HU difference was -2.679% for normal subjects and -4.403% for COVID-19 patients, indicating minor HU value deviations.
  • Relative volume difference was 2.405% for normal subjects and 5.928% for COVID-19 patients, showing acceptable volume estimation accuracy.
  • The model demonstrated slightly better performance on normal lungs, but still achieved high accuracy on COVID-19-affected lungs, confirming its robustness.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.