Antônio H. Ribeiro, Antônio H. Ribeiro|arXiv (Cornell University)|Nov 28, 2018
ECG Monitoring and AnalysisMedicine35 references6 citations
TL;DR

This paper proposes a deep residual convolutional neural network that automatically diagnoses six common 12-lead ECG abnormalities from short-duration (7–10 second) ECG signals. Trained on a novel dataset of over 2 million real-world clinical ECGs, the model outperforms fourth-year cardiology residents on five of six abnormality classifications, achieving F1 scores above 80% and specificity over 99%.

ABSTRACT

We present a model for predicting electrocardiogram (ECG) abnormalities in short-duration 12-lead ECG signals which outperformed medical doctors on the 4th year of their cardiology residency. Such exams can provide a full evaluation of heart activity and have not been studied in previous end-to-end machine learning papers. Using the database of a large telehealth network, we built a novel dataset with more than 2 million ECG tracings, orders of magnitude larger than those used in previous studies. Moreover, our dataset is more realistic, as it consist of 12-lead ECGs recorded during standard in-clinics exams. Using this data, we trained a residual neural network with 9 convolutional layers to map 7 to 10 second ECG signals to 6 classes of ECG abnormalities. Future work should extend these results to cover a large range of ECG abnormalities, which could improve the accessibility of this diagnostic tool and avoid wrong diagnosis from medical doctors.

Motivation & Objective

  • To develop an end-to-end deep learning model for automatic diagnosis of 12-lead ECG abnormalities using raw signal inputs.
  • To address the lack of large-scale, real-world, fully labeled 12-lead ECG datasets suitable for training deep learning models.
  • To improve diagnostic accuracy and accessibility in primary care and low-resource settings where cardiologists are scarce.
  • To evaluate the model's performance against clinical experts, specifically fourth-year cardiology residents.
  • To establish a foundation for extending the model to cover a broader range of ECG abnormalities in future work.

Proposed method

  • The model uses a residual neural network with 9 convolutional layers to process 12-lead ECG signals of 7–10 seconds duration.
  • The architecture includes skip connections with 1x1 convolutional layers to match tensor dimensions across residual blocks.
  • A sigmoid activation function is applied to the final layer to produce multi-class probability outputs for six ECG abnormalities.
  • The model is trained using binary cross-entropy loss and the Adam optimizer with a decaying learning rate strategy.
  • Training runs for 50 epochs with early stopping based on validation loss, and the best-performing model is selected.
  • A manual threshold is set for each class based on the inflection point of the precision-recall curve to determine positive predictions.

Experimental results

Research questions

  • RQ1Can a deep convolutional neural network achieve superior diagnostic performance on 12-lead ECGs compared to trained medical professionals?
  • RQ2How effective is an end-to-end deep learning approach on real-world, short-duration 12-lead ECGs collected in clinical settings?
  • RQ3Can a large-scale, real-world ECG dataset enable high-accuracy automatic diagnosis across multiple ECG abnormalities?
  • RQ4What is the performance gap between deep learning models and clinical experts in diagnosing common ECG abnormalities?
  • RQ5To what extent can such a model be extended to cover a broader range of ECG diagnoses in future work?

Key findings

  • The deep learning model achieved an F1 score of 0.813 for first-degree AV block, outperforming the 0.776 F1 score of fourth-year cardiology residents.
  • For right bundle branch block, the model achieved an F1 score of 0.935 compared to the doctors' 0.917, with 100% recall and 99.5% specificity.
  • The model achieved 100% recall and 98.5% F1 score for left bundle branch block, surpassing the doctors' 94.7% F1 score.
  • For atrial fibrillation, the model achieved 84.6% F1 score, matching the doctors' performance but with higher specificity (99.8% vs. 99.6%).
  • The model outperformed doctors in F1 score for five out of six ECG abnormalities: 1st degree AV block, RBBB, LBBB, SB, and ST.
  • The model demonstrated high specificity (>99%) across all six abnormalities, indicating strong true negative detection.