[Paper Review] AutoPET Challenge: Combining nn-Unet with Swin UNETR Augmented by Maximum Intensity Projection Classifier
This paper presents a hybrid deep learning approach for 3D semantic segmentation of FDG-PET/CT scans in the AutoPET challenge, combining nn-Unet and Swin UNETR with a maximum intensity projection (MIP)-based classifier as a gating mechanism. The method uses late fusion of segmentation outputs only when the MIP classifier detects potential lesions, achieving a cross-validation Dice score of 72.12% on lung cancer, melanoma, and lymphoma patients.
Tumor volume and changes in tumor characteristics over time are important biomarkers for cancer therapy. In this context, FDG-PET/CT scans are routinely used for staging and re-staging of cancer, as the radiolabeled fluorodeoxyglucose is taken up in regions of high metabolism. Unfortunately, these regions with high metabolism are not specific to tumors and can also represent physiological uptake by normal functioning organs, inflammation, or infection, making detailed and reliable tumor segmentation in these scans a demanding task. This gap in research is addressed by the AutoPET challenge, which provides a public data set with FDG-PET/CT scans from 900 patients to encourage further improvement in this field. Our contribution to this challenge is an ensemble of two state-of-the-art segmentation models, the nn-Unet and the Swin UNETR, augmented by a maximum intensity projection classifier that acts like a gating mechanism. If it predicts the existence of lesions, both segmentations are combined by a late fusion approach. Our solution achieves a Dice score of 72.12\% on patients diagnosed with lung cancer, melanoma, and lymphoma in our cross-validation. Code: https://github.com/heiligerl/autopet_submission
Motivation & Objective
- To improve 3D semantic segmentation of FDG-PET/CT scans in oncology, where tumors are often obscured by physiological uptake.
- To address false positive segmentations caused by non-malignant metabolic activity in organs, inflammation, or infection.
- To develop a robust, automated solution for tumor volume assessment across diverse cancer types (lung, melanoma, lymphoma).
- To leverage attention-based architectures (Swin UNETR) and efficient segmentation (nn-Unet) in a late-fusion pipeline with a classifier gate.
- To validate the method on a large public dataset of 900 patients from the AutoPET challenge, emphasizing clinical relevance and generalization.
Proposed method
- The pipeline uses axial and sagittal maximum intensity projections (MIPs) of PET scans as input to a binary classifier ensemble to detect pathological uptake.
- The classifier ensemble combines ResNet18 and ResNet50 backbones, trained on MIPs with and without brain structures, using decision-level late fusion via logical OR.
- A conservative threshold (γ=0.3) is applied to reduce false negatives, and only if any classifier detects lesions is segmentation performed.
- Segmentation is performed using two state-of-the-art models: nn-Unet (3D U-Net with automated hyperparameter tuning) and Swin UNETR (transformer-based 3D segmentation model).
- The outputs of nn-Unet and Swin UNETR are fused via averaging before post-processing.
- Post-processing includes removing small predictions (<10 voxels) and boundary suppression (0.5–12% of z-slices), though improvements were marginal.
Experimental results
Research questions
- RQ1Can a MIP-based classifier effectively act as a gating mechanism to avoid unnecessary segmentation in healthy patients?
- RQ2How does late fusion of nn-Unet and Swin UNETR improve segmentation performance compared to individual models?
- RQ3Does the use of de-brained MIPs improve classifier generalization and reduce false positives?
- RQ4To what extent do attention mechanisms in Swin UNETR complement the inductive bias of nn-Unet in 3D tumor segmentation?
- RQ5What is the optimal balance between false positive volume (FPV) and false negative volume (FNV) in clinical segmentation pipelines?
Key findings
- The ensemble classifier achieved a cross-validation accuracy of 74.3% with only 2.4 false negatives and 49.6 false positives per fold.
- The MIP-Y (axial) view consistently outperformed MIP-X (sagittal), with a top accuracy of 91.09% using EfficientNet-B4 on MIP-Y with brain.
- De-brained MIPs led to a different FN/FP distribution, suggesting complementary feature learning and potential benefit from ensemble training on both variants.
- Late fusion of nn-Unet and Swin UNETR improved performance, with the latter likely contributing via long-range context modeling.
- Post-processing steps had minimal impact, reducing only one tumor prediction and marginally reducing false positives in healthy cases.
- The final solution achieved a mean cross-validation Dice score of 72.12% on patients with lung cancer, melanoma, and lymphoma, outperforming baseline models in the AutoPET challenge.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.