This study reports a high-sensitivity axion dark matter search using the CAPP-12TB haloscope at the Dine-Fischler-Srednicki-Zhitnitskii (DFSZ) axion model, achieving a 90% confidence level exclusion limit of $ g_{a\gamma\gamma} < 6.2 \times 10^{-16} \, \text{GeV}^{-1} $ for axion masses between 4.51 and 4.59 $\mu$eV. The experiment leverages a microwave cavity with a strong magnetic field to resonantly convert axions into detectable photons, demonstrating state-of-the-art sensitivity near 4.55 $\mu$eV.
We report an axion dark matter search at Dine-Fischler-Srednicki-Zhitnitskii sensitivity with the CAPP-12TB haloscope, assuming axions contribute 100\% of the local dark matter density. The search excluded the axion--photon coupling $g_{aγγ}$ down to about $6.2 imes10^{-16}$ GeV$^{-1}$ over the axion mass range between 4.51 and 4.59 $μ$eV at a 90\% confidence level. The achieved experimental sensitivity can also exclude Kim-Shifman-Vainshtein-Zakharov axion dark matter that makes up just 13\% of the local dark matter density. The CAPP-12TB haloscope will continue the search over a wide range of axion masses.
Motivation & Objective
- To search for axion dark matter in the 4.51–4.59 $\mu$eV mass range using the CAPP-12TB haloscope.
- To test the Dine-Fischler-Srednicki-Zhitnitskii (DFSZ) axion model with high experimental sensitivity.
- To set a new exclusion limit on the axion–photon coupling $ g_{a\gamma\gamma} $ at the 90% confidence level.
- To demonstrate sensitivity to axion dark matter accounting for only 13% of the local dark matter density.
- To validate the performance of a low-noise, high-gain JPA-based readout system in a cryogenic haloscope setup.
Proposed method
- Utilizes a microwave cavity with a strong static magnetic field to resonantly convert axions into detectable photons via the axion–photon coupling $ g_{a\gamma\gamma} $.
- Employs a Josephson Parametric Amplifier (JPA) with a Lorentzian gain profile to achieve near-quantum-limited amplification of weak microwave signals.
- Applies the Y-factor method to measure the total system gain $ G_{\rm{total}} $, enabling accurate noise temperature calibration.
- Measures the total system noise temperature $ T_n $ using both a calibrated noise source and the cavity itself, ensuring consistency across measurements.
- Corrects for line attenuation between the cavity and microwave switch using vector network analyzer (VNA) reflection measurements, finding 0.3–0.5 dB loss.
- Uses a dual-temperature calibration method with a 400 mK and 100 mK noise source to determine $ G_{\rm{JPA_{off}}} $, with a 2% sensor uncertainty assigned to the temperature measurement.
Experimental results
Research questions
- RQ1What is the sensitivity of the CAPP-12TB haloscope to axion dark matter in the DFSZ model near 4.55 $\mu$eV?
- RQ2Can the experiment exclude axion–photon coupling strengths below $ 6.2 \times 10^{-16} \, \text{GeV}^{-1} $ at 90% confidence level?
- RQ3How well does the JPA-based readout system perform in terms of noise temperature and gain stability in a cryogenic haloscope setup?
- RQ4To what extent can the system detect axion dark matter if it constitutes only 13% of the local dark matter density?
- RQ5What is the impact of line attenuation and thermal non-equilibrium on the total system noise temperature?
Key findings
- The experiment achieved a 90% confidence level exclusion limit of $ g_{a\gamma\gamma} < 6.2 \times 10^{-16} \, \text{GeV}^{-1} $ for axion masses between 4.51 and 4.59 $\mu$eV.
- The total system noise temperature $ T_n $ was measured to be approximately 140 mK around the target frequency, with a 6% systematic uncertainty.
- The noise temperature at ±100 kHz detuning from the target frequency was 130 mK and 190 mK, respectively, consistent with the Lorentzian JPA gain profile.
- The two independent $ T_n $ measurements—one using a calibrated noise source and one using the cavity as a noise source—differed by at most 5%, indicating consistency.
- The line attenuation from the cavity to the microwave switch was measured at 0.3–0.5 dB, which was corrected in the total gain calibration.
- The system is sensitive enough to exclude Kim-Shifman-Vainshtein-Zakharov (KSVZ) axion dark matter if it contributes only 13% of the local dark matter density.