Skip to main content
QUICK REVIEW

[Paper Review] Bright 5 - 85 MeV Compton gamma-ray pulses from GeV laser-plasma accelerator and plasma mirror

Joseph M. Shaw, Bernstein, A. C.|arXiv (Cornell University)|May 24, 2017
Advanced Radiotherapy TechniquesPhysics and Astronomy1 references4 citations
TL;DR

This paper demonstrates a compact, femtosecond-pulsed Compton gamma-ray source producing 5–85 MeV photons by using a 100 µm glass plasma mirror to retro-reflect a GeV laser-plasma accelerator's spent drive laser pulse onto trailing electrons. The method achieves peak brilliance of ~10²¹ photons/s/mm²/mrad²/0.1% bandwidth with sub-mrad divergence and near-unity reliability, enabling tunable, quasi-monochromatic gamma-ray pulses for nuclear photonic applications.

ABSTRACT

We convert a GeV laser-plasma electron accelerator into a compact femtosecond-pulsed $γ$-ray source by inserting a $100 μ$m-thick glass plate $\sim3$ cm after the accelerator exit. With near-unity reliability, and requiring only crude alignment, this glass plasma mirror retro-reflected spent drive laser pulses (photon energy $\hbarω_L = 1.17$ eV) with $>50\%$ efficiency back onto trailing electrons (peak Lorentz factor $1000 < γ_e < 4400$), creating an optical undulator that generated $\sim10^8 γ$-ray photons with sub-mrad divergence, estimated peak brilliance $\sim10^{21}$ photons/s/mm$^2$/mrad$^2$/$0.1\%$ bandwidth and negligible bremsstrahlung background. The $γ$-ray photon energy $E_γ= 4γ_e^2 \hbarω_L$, inferred from the measured $γ_e$ on each shot, peaked from 5 to 85 MeV, spanning a range otherwise available with comparable brilliance only from large-scale GeV-linac-based high-intensity $γ$-ray sources.

Motivation & Objective

  • To develop a compact, high-brightness, femtosecond-pulsed Compton gamma-ray source using a laser-plasma accelerator.
  • To overcome the challenge of maintaining plasma mirror reflectivity in high-power, pre-pulse-dominated GeV laser-plasma accelerators.
  • To enable tunable, quasi-monochromatic gamma-ray pulses in the 5–85 MeV range with high brilliance and low bremsstrahlung background.
  • To provide a scalable alternative to large-scale linac-based gamma-ray sources for nuclear photonic research.
  • To demonstrate that plasma mirrors can serve as reliable, alignment-tolerant optical undulators for Compton backscattering.

Proposed method

  • A 100 µm-thick glass plate is placed ~3 cm after the GeV laser-plasma accelerator exit to act as a plasma mirror (PM).
  • The PM retro-reflects the spent drive laser pulse (ħωL = 1.17 eV) with >50% efficiency onto trailing electrons with Lorentz factors 1000 < γe < 4400.
  • The interaction creates an optical undulator via Compton backscattering, generating gamma rays with energy Eγ = 4γe²ħωL.
  • The gamma-ray beam is diagnosed using a pixelated scintillator, and electron energy is measured via magnetic spectrometry with tungsten wire fiducials.
  • Beam pointing and divergence are correlated between electrons and gamma rays to infer electron beam angle and transverse emittance.
  • The source size is estimated at 20 µm, and gamma-ray pulse duration is inferred as ~80 fs from plasma density (ne ≈ 5×10¹⁷ cm⁻³).

Experimental results

Research questions

  • RQ1Can a plasma mirror reliably retro-reflect a high-power, pre-pulse-contaminated laser pulse in a GeV laser-plasma accelerator to enable Compton gamma-ray generation?
  • RQ2What is the achievable gamma-ray photon energy range and brilliance when using a plasma mirror as an optical undulator in a compact laser-plasma accelerator?
  • RQ3How do gamma-ray beam parameters (energy, divergence, pulse duration) correlate with electron beam properties (energy, angle, emittance)?
  • RQ4Can the plasma mirror technique produce quasi-monochromatic, low-background gamma-ray pulses suitable for nuclear photonic applications?
  • RQ5To what extent can the gamma-ray beam profile be used to diagnose electron beam parameters such as launch angle and transverse emittance?

Key findings

  • The plasma mirror achieved >50% reflectivity and retro-reflected the laser pulse with near-unity reliability, enabling consistent gamma-ray production.
  • Gamma-ray photon energies ranged from 5 to 85 MeV, tunable via electron energy (0.5–2.2 GeV), with peak brilliance estimated at ~10²¹ photons/s/mm²/mrad²/0.1% bandwidth.
  • The gamma-ray beam had a half-cone divergence of 1±0.3 mrad and spectral full width at half maximum (FWHM) of 15±11 MeV across the tuning range.
  • The number of gamma-ray photons within the FWHM (0.1% bandwidth) ranged from 0.3×10⁷ to 173×10⁷ per shot, with the highest peak at 173×10⁷ photons.
  • A strong correlation (R² = 0.94) was observed between electron beam divergence (θe) and gamma-ray beam divergence (θγ), with θγ = 1.26θe + 0.4 mrad.
  • The gamma-ray beam profile enabled direct diagnosis of electron beam launch angle and transverse emittance, offering a more accurate alternative to conventional two-screen electron diagnostics.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.