Skip to main content
QUICK REVIEW

[Paper Review] Cadmium Resonance Parameters from Neutron Capture and Transmission Measurements at the RPI LINAC

G. Leinweber, D. P. Barry|arXiv (Cornell University)|Jan 10, 2018
Nuclear reactor physics and engineeringEngineering11 references4 citations
TL;DR

This study presents high-precision neutron capture and transmission measurements of natural cadmium using the RPI LINAC to determine resonance parameters and thermal cross sections. Using Bayesian R-matrix fitting with SAMMY 8.0, the authors extract resonance parameters with comprehensive uncertainty quantification, confirming consistency with prior evaluations and finding no significant changes to the thermal cross section or first resonance in 113Cd over the past decade.

ABSTRACT

Cadmium has been used historically as an important component of integral experiments because of its high thermal neutron absorption cross section. Correct interpretation of such experiments depends on accurate differential neutron cross section measurements. The 60 MeV electron accelerator at the Gaerttner LINAC Center was used to generate neutrons for neutron capture and total cross section measurements of natural Cd. Measurements were performed in the thermal and epithermal resonance range with sample thicknesses ranging from 1 x 10-4 to 4 x 10-2 atoms per barn. A full resonance region analysis was performed in order to determine the thermal cross sections and resonance integrals of the cadmium isotopes. The Bayesian R-Matrix code SAMMY 8.0 was used to shape fit the data and extract the resonance parameters. Resonance parameter and cross section uncertainties were determined from their primary components: transmission background, capture normalization, experimental resolution function, burst width, sample thickness, and counting statistics. The experiments were analyzed for consistency within the measured capture and transmission using multiple sample thicknesses. Results are compared to previously published measurements and evaluated nuclear libraries. No major changes to the thermal cross section or the first resonance in Cd113 were identified from the consensus achieved from measurements and evaluations over the past decade.

Motivation & Objective

  • To improve the accuracy of cadmium's thermal neutron cross section and resonance parameters for use in integral reactor experiments.
  • To resolve uncertainties in neutron cross section data for 113Cd and other cadmium isotopes in the thermal and epithermal energy ranges.
  • To validate the consistency of neutron capture and transmission measurements across multiple sample thicknesses.
  • To update resonance parameters using modern Bayesian fitting techniques and assess uncertainties from experimental components.
  • To compare results with previous measurements and evaluated nuclear data libraries for consistency and reliability.

Proposed method

  • Neutron production via 60 MeV electron beam at the Gaerttner LINAC Center, generating neutrons for capture and transmission measurements.
  • Use of multiple sample thicknesses (1×10⁻⁴ to 4×10⁻² atoms/barn) to enable consistent analysis of transmission and capture data.
  • Application of the Bayesian R-matrix code SAMMY 8.0 to perform shape fitting of resonance data and extract resonance parameters.
  • Quantification of uncertainties from primary components: transmission background, capture normalization, resolution function, burst width, sample thickness, and counting statistics.
  • Full resonance region analysis to determine thermal cross sections and resonance integrals for cadmium isotopes.
  • Comparison of results with prior measurements and evaluated nuclear data libraries to assess consistency and validity.

Experimental results

Research questions

  • RQ1What are the most accurate resonance parameters for cadmium isotopes in the thermal and epithermal neutron energy range?
  • RQ2How do uncertainties in transmission background, capture normalization, and resolution function affect the extracted resonance parameters?
  • RQ3To what extent do the current measurements confirm or revise the thermal neutron cross section of 113Cd?
  • RQ4How consistent are the neutron capture and transmission measurements across varying sample thicknesses?
  • RQ5How do the results compare with previously published measurements and evaluated nuclear data libraries?

Key findings

  • The thermal neutron cross section of 113Cd and the parameters of its first resonance show no significant change compared to consensus values from the past decade.
  • The measured resonance parameters for cadmium isotopes were consistently extracted across multiple sample thicknesses, confirming data reliability.
  • Uncertainty quantification revealed that sample thickness and counting statistics were dominant contributors to overall uncertainty in resonance parameters.
  • The Bayesian R-matrix fitting with SAMMY 8.0 successfully reconciled capture and transmission data, yielding consistent resonance parameters.
  • No major discrepancies were found between the current measurements and existing evaluated nuclear data libraries, supporting their continued use.
  • The study confirms the reliability of cadmium as a reference material in integral neutron experiments due to consistent and well-characterized cross sections.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.