[Paper Review] CARE: Training-Free Controllable Restoration for Medical Images via Dual-Latent Steering
CARE is a training-free framework for medical image restoration that uses dual latent branches (fidelity and prior) plus a risk-aware controller to balance data fidelity and prior-driven refinement during inference, enabling controllable restoration without retraining.
Medical image restoration is essential for improving the usability of noisy, incomplete, and artifact-corrupted clinical scans, yet existing methods often rely on task-specific retraining and offer limited control over the trade-off between faithful reconstruction and prior-driven enhancement. This lack of controllability is especially problematic in clinical settings, where overly aggressive restoration may introduce hallucinated details or alter diagnostically important structures. In this work, we propose CARE, a training-free controllable restoration framework for real-world medical images that explicitly balances structure preservation and prior-guided refinement during inference. CARE uses a dual-latent restoration strategy, in which one branch enforces data fidelity and anatomical consistency while the other leverages a generative prior to recover missing or degraded information. A risk-aware adaptive controller dynamically adjusts the contribution of each branch based on restoration uncertainty and local structural reliability, enabling conservative or enhancement-focused restoration modes without additional model training. We evaluate CARE on noisy and incomplete medical imaging scenarios and show that it achieves strong restoration quality while better preserving clinically relevant structures and reducing the risk of implausible reconstructions and show that it achieves strong restoration quality while better preserving clinically relevant structures and reducing the risk of implausible reconstructions. The proposed approach offers a practical step toward safer, more controllable, and more deployment-ready medical image restoration.
Motivation & Objective
- Motivate safer medical image restoration that preserves diagnostically relevant structures while enabling effective enhancement.
- Provide a training-free framework that avoids task-specific retraining for different degradations and imaging protocols.
- Separate restoration into fidelity-guided and prior-guided latent streams and balance them at inference.
- Introduce a risk-aware adaptive controller to modulate reliance on observed data versus generative priors.
Proposed method
- Formulate restoration as a dual-latent fusion: z_f = Phi_f(y) (fidelity) and z_p = Phi_p(y) (prior).
- Fuse latents via z* = alpha * z_f + (1 - alpha) * z_p, where alpha controls fidelity vs. prior influence.
- Develop a risk-aware adaptive controller that computes alpha as alpha = sigma(beta1 * r - beta2 * u + beta3 * lambda) based on reliability r and uncertainty u.
- Operate inference-time without retraining by adjusting alpha to produce conservative, balanced, or enhancement-focused restoration modes.
- Provide an evaluation protocol including quantitative metrics and reader-based clinical trustworthiness assessments.
Experimental results
Research questions
- RQ1Can a training-free dual-latent restoration framework balance data fidelity and prior-driven refinement in medical imaging?
- RQ2How does an adaptive, risk-aware controller affect restoration safety and diagnostic trustworthiness across CT denoising and MRI reconstruction tasks?
- RQ3What are the trade-offs between fidelity preservation and hallucination risk when varying the control parameter lambda?
- RQ4Does the proposed method maintain clinical usability and reduce implausible reconstructions compared with task-specific retrained baselines?
Key findings
- CARE achieves competitive quantitative results on CT denoising and MRI reconstruction benchmarks across different tasks.
- On the fastMRI brain benchmark, CARE attains 4X SSIM of 0.964 and 8X SSIM of 0.955, competitive with or exceeding several baselines.
- CARE’s CT results show PSNR improvements and balanced SSIM, indicating fidelity gains without excessive smoothing.
- Reader studies show CARE achieves best artifact reduction and contrast retention, highlighting improved clinical trustworthiness.