[Paper Review] Catch a Breath: Non-invasive Respiration Rate Monitoring via Wireless Communication

Ossi Kaltiokallio, Hüseyi̇n Yi̇ği̇tler|arXiv (Cornell University)|Jun 29, 2013
Indoor and Outdoor Localization TechnologiesEngineering18 references7 citations
TL;DR

This paper proposes a low-cost, non-invasive respiration rate monitoring system using only a single IEEE 802.15.4-compliant transceiver pair by analyzing received signal strength (RSS) fluctuations caused by respiratory motion. It achieves a record-low mean error of 0.03 breaths per minute and demonstrates simultaneous monitoring of two individuals with distinct breathing frequencies or phases.

ABSTRACT

Radio signals are sensitive to changes in the environment, which for example is reflected on the received signal strength (RSS) measurements of low-cost wireless devices. This information has been used effectively in the past years e.g. in device-free localization and tracking. Recent literature has also shown that the fading information of the wireless channel can be exploited to estimate the breathing rate of a person in a non-invasive manner; a research topic we address in this paper. To the best of our knowledge, we demonstrate for the first time that the respiration rate of a person can be accurately estimated using only a single IEEE 802.15.4 compliant TX-RX pair. We exploit channel diversity, low-jitter periodic communication, and oversampling to enhance the breathing estimates, and make use of a decimation filter to decrease the computational requirements of breathing estimation. In addition, we develop a hidden Markov model (HMM) to identify the time instances when breathing estimation is not possible, i.e., during times when other motion than breathing occurs. We experimentally validate the accuracy of the system and the results suggest that the respiration rate can be estimated with a mean error of 0.03 breaths per minute, the lowest breathing rate error reported to date using IEEE 802.15.4 compliant transceivers. We also demonstrate that the breathing of two people can be monitored simultaneously, a result not reported in earlier literature.

Motivation & Objective

  • To enable non-invasive, low-cost respiration rate monitoring using only low-complexity, off-the-shelf IEEE 802.15.4 transceivers.
  • To overcome motion interference and low signal-to-noise ratio in RSS measurements for reliable breathing estimation.
  • To detect and exclude time intervals when breathing estimation is unreliable due to non-respiratory motion.
  • To demonstrate simultaneous monitoring of multiple individuals with distinct breathing frequencies or phases.
  • To provide a practical, computationally efficient solution suitable for healthcare and ambient assisted living applications.

Proposed method

  • Utilizes RSS measurements from a single TX-RX pair to detect minute channel variations caused by respiratory motion.
  • Employs low-jitter periodic communication and oversampling to enhance signal-to-noise ratio and improve estimation accuracy.
  • Applies a decimation filter to reduce computational load while preserving relevant breathing frequency components.
  • Uses a hidden Markov model (HMM) to detect and flag periods of motion interference, improving robustness.
  • Analyzes power spectral density (PSD) of RSS to extract breathing frequencies and uses phase estimates to distinguish multiple individuals.
  • Leverages channel diversity and amplitude-based channel selection to improve reliability and accuracy.

Experimental results

Research questions

  • RQ1Can respiration rate be accurately estimated using only a single IEEE 802.15.4 transceiver pair without specialized hardware?
  • RQ2How can motion interference from non-respiratory movements be detected and mitigated in RSS-based breathing monitoring?
  • RQ3Can multiple individuals with different breathing frequencies be distinguished from RSS measurements?
  • RQ4Can individuals breathing at the same frequency but different phases be detected and differentiated?
  • RQ5What is the achievable accuracy of respiration rate estimation using only low-cost, narrowband RSS measurements?

Key findings

  • The proposed system achieves a mean respiration rate estimation error of only 0.03 breaths per minute, the lowest reported to date using IEEE 802.15.4 transceivers.
  • The system successfully estimates breathing rates with high accuracy regardless of the subject’s posture, demonstrating robustness.
  • Simultaneous monitoring of two individuals is experimentally validated: two distinct breathing frequencies (12 and 15 bpm) are clearly resolved in the PSD with errors of 0.006 and 0.018 bpm.
  • When two people breathe at the same frequency but with a 90° phase difference, the phase estimates show a distinct dispersion pattern, indicating multiple sources.
  • The amplitude of the estimated signal is effective as a criterion for selecting the most reliable channel for breathing monitoring.
  • The use of a decimation filter reduces computational load without significantly affecting estimation accuracy.