TL;DR

This study reveals a critical discrepancy between radiologists' visual interpretations of chest X-rays and their clinical reports, demonstrating that report-based labels—commonly used to train medical AI—contain significant noise due to clinically non-actionable findings. Even state-of-the-art NLP models trained on these flawed reports achieve only 55.6% of the image-verified findings, undermining model reliability and highlighting the need for improved labeling pipelines in medical AI.

ABSTRACT

Acquiring high-quality annotations in medical imaging is usually a costly process. Automatic label extraction with natural language processing (NLP) has emerged as a promising workaround to bypass the need of expert annotation. Despite the convenience, the limitation of such an approximation has not been carefully examined and is not well understood. With a challenging set of 1,000 chest X-ray studies and their corresponding radiology reports, we show that there exists a surprisingly large discrepancy between what radiologists visually perceive and what they clinically report. Furthermore, with inherently flawed report as ground truth, the state-of-the-art medical NLP fails to produce high-fidelity labels.

Motivation & Objective

  • To investigate the gap between radiologists' visual interpretation of chest X-rays and their clinical reporting in radiology reports.
  • To evaluate the reliability of NLP models in extracting labels from radiology reports when the reports themselves contain inaccuracies.
  • To identify the root causes of labeling discrepancies in medical imaging, particularly non-actionable findings often omitted from reports.
  • To demonstrate that report-based labels are inherently flawed, leading to poor performance in downstream AI models trained on them.
  • To advocate for re-evaluating the use of radiology reports as ground truth in medical AI development.

Proposed method

  • Curated a dataset of 1,000 non-screening chest X-ray studies with radiology reports.
  • Had two groups of expert radiologists independently label findings: one based solely on image review ($y_{\text{img}}^{\text{rad}}$), the other on report review ($y_{\text{txt}}^{\text{rad}}$).
  • Used state-of-the-art medical NLP (from Irvin et al., 2019) to extract labels from reports ($y_{\text{txt}}^{\text{nlp}}$).
  • Quantified agreement between image-based labels and report-based labels using precision, recall, and F1-score.
  • Conducted failure analysis on disagreement cases, categorizing causes into non-actionable findings, borderline/nuanced findings, anatomic variations, technical issues, and outright errors.
  • Compared NLP-extracted labels to radiologist-reported labels to assess NLP performance under real-world data quality constraints.

Experimental results

Research questions

  • RQ1How much disagreement exists between radiologists' visual interpretations of chest X-rays and their clinical reports?
  • RQ2To what extent do non-actionable findings contribute to labeling discrepancies in radiology reports?
  • RQ3How well do state-of-the-art NLP models perform when trained on radiology reports that contain clinically irrelevant or omitted findings?
  • RQ4What are the primary sources of error in report-based labeling, and how do they affect downstream AI model performance?
  • RQ5Can NLP models reliably extract accurate labels when the ground truth (radiology reports) is inherently inconsistent with visual findings?

Key findings

  • The agreement between image-based and report-based labels was only 69% for the Global Abnormal category, the highest among all findings.
  • NLP models achieved only 55.6% of the image-verified findings when using report labels as ground truth, indicating substantial performance degradation.
  • For Cardiomegaly, the F1-score between NLP and report labels was only 0.23, reflecting poor alignment due to reporting inconsistencies.
  • 24% of reports labeled studies as normal, yet image review revealed abnormalities—indicating significant under-reporting of findings.
  • 20% of reports labeled as abnormal were actually normal on imaging, highlighting over-reporting and false positives.
  • The primary cause of disagreement was the omission of non-actionable findings such as medical devices, chronic changes, and age-related findings in radiology reports.