Skip to main content
QUICK REVIEW

[Paper Review] Cavity-QED determination of the natural linewidth of the $^{87}$Sr millihertz clock transition with 30$\mu$Hz resolution

Juan A. Muniz, Dylan J. Young|arXiv (Cornell University)|Jul 15, 2020
Advanced Frequency and Time StandardsPhysics and Astronomy89 references1 citations
TL;DR

This paper presents a cavity-QED method to measure the natural linewidth of the 87Sr millihertz clock transition with 30 µHz resolution, using simultaneous, interleaved nondestructive measurements of light-matter coupling strengths to a known 7.5 kHz transition. The technique achieves a linewidth of γ₀/(2π) = 1.35(3) mHz, corresponding to a lifetime of τ = 118(3) s, enabling detection of states with lifetimes up to 15 hours in sub-second measurements.

ABSTRACT

We present a new method for determining the intrinsic natural linewidth or lifetime of exceptionally long-lived optical excited states. Such transitions are key to the performance of state-of-the-art atomic clocks, have potential applications in searches for fundamental physics and gravitational wave detectors, as well as novel quantum many-body phenomena. With longer lifetime optical transitions, sensitivity is increased, but so far it has proved challenging to determine the natural lifetime of many of these long lived optical excited states because standard population decay detection techniques become experimentally difficult. Here, we determine the ratio of a poorly known ultranarrow linewidth transition ($^3$P$_0$ to $^1$S$_0$ in $^{87}$Sr) to that of another narrow well known transition ($^3$P$_1$ to $^1$S$_0$) by coupling the two transitions to a single optical cavity and performing interleaved nondestructive measurements of the interaction strengths of the atoms with cavity modes near each transition frequency. We use this approach to determine the natural linewidth of the clock transition $^3$P$_0$ to $^1$S$_0$ in $^{87}$Sr to be $\gamma_0/(2\pi) = 1.35(3)~$mHz or $ au= 118(3)~$s. The 30$~\mu$Hz resolution implies that we could detect states with lifetimes just below 2 hours, and with straightforward future improvements, we could detect states with lifetimes up to 15 hours, using measurement trials that last only a few hundred milliseconds, eliminating the need for long storage times in optical potentials.

Motivation & Objective

  • To determine the intrinsic natural linewidth of the ultranarrow 87Sr 3P₀ to 1S₀ clock transition, which is critical for optical clock performance and fundamental physics.
  • To overcome the experimental challenge of measuring lifetimes exceeding 100 s using standard population decay techniques.
  • To develop a method that cancels common-mode noise and systematic errors by comparing coupling strengths to a well-characterized 7.5 kHz transition.
  • To enable high-resolution linewidth measurements without requiring long storage times in optical potentials.

Proposed method

  • Uses a single atomic ensemble in an optical cavity to simultaneously probe the millihertz clock transition (3P₀ → 1S₀) and a well-known 7.5 kHz transition (3P₁ → 1S₀).
  • Performs nondestructive, interleaved measurements of dispersive phase shifts (∆ϕ₀, ∆ϕ₁) on both transitions to extract the ratio of light-matter coupling strengths (g₀/g₁).
  • Applies a ratio-based approach to determine the linewidth ratio γ₀/γ₁ using the formula γ₀/γ₁ = (g₀/g₁)² × (w₀/w₁)² × (ωA₀/ωA₁)² × (L₀/L₁), with all geometric and atomic parameters independently characterized.
  • Corrects for systematic effects such as cavity and laser frequency noise, atom number fluctuations, and inhomogeneous coupling via a zero-power crossing measurement and global fitting.
  • Uses a global fit across multiple data sets (red, green, blue) to extract the zero-power phase shift ratio, minimizing uncertainty from alignment drifts.
  • Applies a systematic correction factor FC to account for higher-order effects, ensuring robustness against unknown N-dependent offsets.

Experimental results

Research questions

  • RQ1What is the natural linewidth of the 87Sr 3P₀ clock transition, given its exceptionally long lifetime?
  • RQ2Can the linewidth of an ultranarrow transition be measured with sub-mHz resolution without relying on long-lived population decay?
  • RQ3How can common-mode noise and systematic errors be suppressed in high-precision linewidth measurements of long-lived states?
  • RQ4To what extent do atom number and non-linear effects influence the measured coupling ratio in cavity-QED-based linewidth determination?

Key findings

  • The natural linewidth of the 87Sr 3P₀ to 1S₀ clock transition is measured as γ₀/(2π) = 1.35(3) mHz, with a 30 µHz resolution.
  • The corresponding excited-state lifetime is τ = 118(3) s, consistent with ab initio predictions of 110–130 s.
  • The method achieves a 2% constraint on unknown N-dependent effects in the phase shift ratio, which is below the final uncertainty.
  • The technique enables detection of states with lifetimes up to 15 hours using measurement trials lasting only a few hundred milliseconds.
  • The measured linewidth ratio γ₀/γ₁ is derived from (g₀/g₁)² = 1.83(3) × 10⁻⁷, with all geometric and atomic parameters independently known.
  • The approach eliminates the need for long storage times in optical potentials, overcoming a major limitation in traditional linewidth measurement.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.