Skip to main content
QUICK REVIEW

[Paper Review] Chemical Abundances of NGC 5461 and NGC 5471 derived from Echelle Spectrophotometry

V. Luridiana, C. Esteban|LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)|May 2, 2002
Astrophysics and Star Formation StudiesPhysics and Astronomy2 references9 citations
TL;DR

This study presents high-resolution echelle spectrophotometry of the giant H II regions NGC 5461 and NGC 5471 in M101, deriving physical conditions and chemical abundances using tailored photoionization models and ionization correction factors (ICFs). It reveals significant discrepancies between ICFs from the Mathis & Rosa (1991) method and model-based ICFs—especially for nitrogen, neon, chlorine, and argon—indicating limitations in standard ICF prescriptions for these elements in metal-poor, ionization-bounded H II regions.

ABSTRACT

We present high resolution spectroscopic data of the two giant extragalactic H II regions NGC 5461 and NGC 5471 in M101, which have been obtained with the 2.1-m telescope of the Observatorio Astronómico Nacional in San Pedro Mártir, Baja California. We measured the intensities of several H and He recombination lines, and of forbidden lines of a large number of ions. We calculate the physical conditions in the two nebulae with a large number of diagnostics and determine their chemical abundances by applying ionization correction factors icf's to the observed ionic abundances. For NGC 5461, the icf's are based on a tailored photoionization model of the region (Luridiana & Peimbert 2001), while for NGC 5471 they are computed from those predicted by a photoionization model of NGC 2363 (Luridiana, Peimbert, & Leitherer 1999), a region which is similar to NGC 5471 in the ionization structure. For both regions, the icf's are compared to those computed following the prescriptions by Mathis & Rosa (1991). Such comparison shows large discrepancies for several elements, including nitrogen, neon, and chlorine.

Motivation & Objective

  • To determine accurate chemical abundances in two giant extragalactic H II regions, NGC 5461 and NGC 5471, in the spiral galaxy M101.
  • To improve ionization correction factor (ICF) accuracy by using tailored photoionization models instead of empirical formulas.
  • To assess the reliability of the Mathis & Rosa (1991) ICF method by comparing it with model-derived ICFs for key elements.
  • To investigate discrepancies in ICFs for nitrogen, neon, chlorine, and argon, particularly in ionization-bounded nebulae.
  • To evaluate the impact of density fluctuations and charge-exchange reactions on abundance determinations.

Proposed method

  • High-resolution echelle spectrophotometry was obtained with the 2.1-m telescope at San Pedro Mártir Observatory, covering 3450–9100 Å with spectral resolution of 0.5 Å FWHM.
  • Line intensities of hydrogen and helium recombination lines, plus forbidden lines of multiple ions (e.g., [O II], [S II], [Ar IV]), were measured for physical condition diagnostics.
  • Physical conditions (electron temperature and density) were derived using multiple independent diagnostics, including [O III] λ4363, [S II] λλ6717,6731, and [Ar IV] λ4711.
  • Ionization correction factors (ICFs) for unobserved ionic states were computed using a custom photoionization model for NGC 5461 (Luridiana & Peimbert 2001) and a model for NGC 2363 (Luridiana et al. 1999) for NGC 5471 due to similar ionization structure.
  • ICF values were compared with those predicted by the empirical method of Mathis & Rosa (1991) to assess systematic biases.
  • Total elemental abundances were calculated by combining observed ionic abundances with ICFs, accounting for ionization structure and filling factors.

Experimental results

Research questions

  • RQ1How do ICFs derived from detailed photoionization models compare to those from the Mathis & Rosa (1991) empirical formula for NGC 5461 and NGC 5471?
  • RQ2To what extent do discrepancies in ICFs for nitrogen, neon, chlorine, and argon affect the derived total elemental abundances?
  • RQ3What causes the observed overestimation of ICFs for Ne++ and Cl++ when using the Mathis & Rosa (1991) method compared to model-based ICFs?
  • RQ4How do ionization-bounded conditions and charge-exchange reactions (e.g., O++ + H⁰ → O⁺ + H⁺) influence ICF reliability in NGC 5461?
  • RQ5Are the abundance determinations for NGC 5461 more uncertain than for NGC 5471 due to model-dependent ICFs and ionization structure?

Key findings

  • The ICF for N⁺ in NGC 5461 derived from the Luridiana & Peimbert (2001) model is about a factor of two higher than that from the Mathis & Rosa (1991) method.
  • The ICF for Ne++ in NGC 5461 is also about a factor of two higher than the Mathis & Rosa (1991) prediction, suggesting potential overestimation in the empirical method.
  • For NGC 5461, the model-based ICF for Ne++ is higher than the empirical ICF and also higher than the value derived from the empirical relation Ne++/O++ = Ne/O, indicating possible model overestimation.
  • The derived log(O/Ne) ratio for NGC 5461 is likely an upper limit due to charge-exchange reactions that reduce the effective Ne++ ICF.
  • For NGC 5471, the ICF for Cl++ from the Mathis & Rosa (1991) method yields log(Cl/O) = -2.81, while the model-based ICF gives log(Cl/O) = -3.71, showing a large discrepancy.
  • The ICF for Ar++ from the Mathis & Rosa (1991) method predicts log(Ar/O) = -1.67, but the model-based ICF gives log(Ar/O) = -2.38, indicating a significant overestimation by the empirical method.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.