Skip to main content
QUICK REVIEW

[Paper Review] CMU-Net: A Strong ConvMixer-based Medical Ultrasound Image Segmentation Network

Fenghe Tang, Lingtao Wang|arXiv (Cornell University)|Oct 24, 2022
Medical Imaging and AnalysisEngineering15 references15 citations
TL;DR

CMU-Net is a novel fully convolutional network for medical ultrasound image segmentation that integrates a ConvMixer module to capture global context and a multi-scale attention gate for enhanced skip connections. It achieves state-of-the-art performance with 73.27% mean IoU and 84.16% F1 score on the BUSI dataset, and 84.75% IoU and 91.71% F1 score on the TUS dataset, outperforming U-Net and Transformer-based models on small datasets.

ABSTRACT

U-Net and its extensions have achieved great success in medical image segmentation. However, due to the inherent local characteristics of ordinary convolution operations, U-Net encoder cannot effectively extract global context information. In addition, simple skip connections cannot capture salient features. In this work, we propose a fully convolutional segmentation network (CMU-Net) which incorporates hybrid convolutions and multi-scale attention gate. The ConvMixer module extracts global context information by mixing features at distant spatial locations. Moreover, the multi-scale attention gate emphasizes valuable features and achieves efficient skip connections. We evaluate the proposed method using both breast ultrasound datasets and a thyroid ultrasound image dataset; and CMU-Net achieves average Intersection over Union (IoU) values of 73.27% and 84.75%, and F1 scores of 84.81% and 91.71%. The code is available at https://github.com/FengheTan9/CMU-Net.

Motivation & Objective

  • To address the limitation of U-Net's local receptive fields in capturing global context in ultrasound images.
  • To improve feature transfer in skip connections by replacing simple concatenation with a learnable attention mechanism.
  • To develop an efficient, fully convolutional architecture that performs well on small medical image datasets without excessive computational cost.
  • To validate the effectiveness of ConvMixer and multi-scale attention gates in enhancing segmentation accuracy for breast and thyroid ultrasound images.

Proposed method

  • The encoder uses standard 3×3 convolutions followed by a ConvMixer block with large kernel depthwise and pointwise convolutions to aggregate long-range spatial dependencies.
  • The ConvMixer block applies depthwise convolution with kernel size 7×7 and 1×1 pointwise convolution, followed by GELU activation and batch normalization.
  • A multi-scale attention gate is introduced to suppress irrelevant features and emphasize salient features in skip connections, using learnable attention weights across multiple scales.
  • The decoder uses bilinear upsampling and concatenation with gated features to refine segmentation masks.
  • The network is trained with a hybrid loss combining binary cross-entropy and dice loss to balance class imbalance.
  • Experiments use data augmentation including random rotation and flip, with input resizing to 256×256 and a batch size of 8 over 300 epochs.

Experimental results

Research questions

  • RQ1Can a ConvMixer-based encoder effectively capture global context in ultrasound images where local convolutions fail?
  • RQ2Does the proposed multi-scale attention gate improve feature transfer in skip connections compared to standard concatenation?
  • RQ3How does CMU-Net perform on small medical ultrasound datasets compared to U-Net and Transformer-based models like TransUnet?
  • RQ4What is the optimal depth and kernel size for the ConvMixer block in this segmentation task?
  • RQ5To what extent do the ablation components (ConvMixer and attention gate) contribute to the final performance gain?

Key findings

  • CMU-Net achieves a mean Intersection over Union (IoU) of 73.27% and an F1 score of 84.16% on the BUSI breast ultrasound dataset, outperforming U-Net by 2.89 percentage points in IoU and 2.00 percentage points in F1 score.
  • On the TUS thyroid ultrasound dataset, CMU-Net achieves 84.75% IoU and 91.71% F1 score, demonstrating superior performance over all compared models including TransUnet.
  • The ablation study confirms that adding the ConvMixer block improves IoU from 68.49% (original U-Net) to 72.36%, and adding the multi-scale attention gate further increases it to 73.27%.
  • The multi-scale attention gate significantly enhances knowledge transfer by emphasizing relevant features, as shown by the consistent performance gains across metrics.
  • CMU-Net maintains high accuracy (97.33%) and robustness across multiple random splits, indicating strong generalization on small datasets.
  • The model outperforms TransUnet on small datasets, suggesting that the ConvMixer-based approach is more data-efficient than hybrid CNN-Transformer architectures.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.