Skip to main content
QUICK REVIEW

[Paper Review] Combination of the top-quark mass measurements from the Tevatron and from the LHC colliders

F. Déliot|arXiv (Cornell University)|Feb 4, 2013
Particle physics theoretical and experimental studiesPhysics and Astronomy6 citations
TL;DR

This paper presents a combined measurement of the top-quark mass from the Tevatron and LHC using the Best Unbiased Linear Estimate (BLUE) method, integrating 12 Tevatron and 7 LHC measurements. The final combined result is $ m_t = 173.2 \pm 0.9 $ GeV, achieving a precision of 0.54% and representing a key input for testing the Standard Model's electroweak sector.

ABSTRACT

I present here the results for the combination of the top-quark mass (mt) measurements at the Tevatron and at the LHC. These combinations are based on measurements using up to 5.8 fb-1 from CDF and D0 yielding mt=173.18 +- 0.56(stat) +- 0.75(syst) GeV, and up to 4.7 fb-1 from ATLAS and CMS leading to mt=173.3 +-0.5(stat) +-1.3(syst) GeV.

Motivation & Objective

  • To improve the precision of the top-quark mass measurement by combining results from the Tevatron and LHC, reducing overall uncertainty.
  • To enable a more stringent test of the Standard Model by constraining the Higgs boson mass via electroweak precision observables.
  • To reduce systematic uncertainties through a common splitting and correlation framework for systematic sources across experiments.
  • To provide a benchmark for future top-quark mass measurements at the LHC with increased statistics.

Proposed method

  • The Best Unbiased Linear Estimate (BLUE) method is used to combine measurements, computing a weighted average based on inverse covariance matrices of input results.
  • Systematic uncertainties are split into 15 distinct components with defined correlations across experiments, run periods, and channels to ensure accurate error propagation.
  • The method accounts for correlations between systematic sources such as jet energy scale (JES), signal modeling, and background fractions, with 100% correlation within experiments and run periods.
  • The combination includes 12 Tevatron measurements (from CDF and D0) and 7 LHC measurements (from ATLAS and CMS) across multiple decay channels and data sets.
  • Uncertainties from initial- and final-state radiation and color reconnection are treated as 50% correlated between LHC experiments, while underlying event modeling is separated as a distinct source.
  • The final combined value is derived by minimizing the variance of the estimator under the constraint of unbiasedness, using the full error matrix of inputs.

Experimental results

Research questions

  • RQ1What is the most precise combined value of the top-quark mass from all available Tevatron and LHC measurements?
  • RQ2How do correlations between systematic uncertainties across experiments and channels affect the final combined uncertainty?
  • RQ3To what extent can systematic uncertainties be reduced through data-driven calibration and improved modeling in future measurements?
  • RQ4How consistent are the individual measurements from different experiments and channels, as quantified by the $\chi^2$ test?

Key findings

  • The combined top-quark mass from the Tevatron is $ m_t = 173.18 \pm 0.56 \, (\text{stat}) \pm 0.75 \, (\text{syst}) $ GeV, with a total uncertainty of 0.94 GeV and a relative precision of 0.54%.
  • The LHC combination yields $ m_t = 173.3 \pm 0.5 \, (\text{stat}) \pm 1.3 \, (\text{syst}) $ GeV, with a total uncertainty of 1.4 GeV and a $\chi^2$ probability of 86% for consistency among inputs.
  • The final combined result of Tevatron and LHC measurements is $ m_t = 173.2 \pm 0.9 $ GeV, representing a precision of 0.54%.
  • The largest contributors to uncertainty in the Tevatron combination are statistical uncertainty (0.56 GeV), in-situ light-jet calibration (0.39 GeV), and signal modeling (0.51 GeV).
  • The largest uncertainties in the LHC combination arise from initial- and final-state radiation (0.69 GeV), color reconnection (0.55 GeV), and b-jet response (0.68 GeV).
  • The combination is robust to systematic variations: changing correlations from 100% to 0% shifts the central value by less than 200 MeV.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.