TL;DR

This paper refutes the claim by Wang et al. that a current-carrying wire through a magnetic core constitutes a 'real memristor' (Φ-memristor). The authors demonstrate that the proposed model rests on incorrect magnetization dynamics, fails to reproduce hysteretic behavior seen in real ferromagnetic materials, contradicts experimental curves, and fails a newly proposed memristor test based on charge recovery, proving the device is merely an inductor with memory.

ABSTRACT

Wang et al. claim [J. Appl. Phys. 125, 054504 (2019)] that a current-carrying wire interacting with a magnetic core represents a memristor. Here, we demonstrate that this claim is false. We first show that such memristor "discovery" is based on incorrect physics, which does not even capture basic properties of magnetic core materials, such as their magnetic hysteresis. Moreover, the predictions of Wang et al.'s model contradict the experimental curves presented in their paper. Additionally, the theoretical pinched hysteresis loops presented by Wang et al. can not be reproduced if their model is used, and there are serious flaws in their "negative memristor" emulator design. Finally, a simple gedanken experiment shows that the proposed $Φ$-memristor would fail the memristor test we recently suggested in J. Phys. D: Appl. Phys. 52, 01LT01 (2019). The device "discovered" by Wang et al. is just an inductor with memory.

Motivation & Objective

  • To challenge the claim by Wang et al. that a current-carrying wire through a magnetic core constitutes a true memristor.
  • To expose the fundamental error in the magnetization dynamics model used in the Φ-memristor proposal.
  • To demonstrate inconsistencies between the theoretical predictions and experimental curves presented in the original paper.
  • To validate that the device fails a recently proposed memristor test based on charge recovery and state return.
  • To reaffirm that the system is correctly classified as a meminductive system (inductor with memory), not a memristor.

Proposed method

  • Analyzing the proposed magnetization dynamics equation m(t) = tanh[q(t)/S_W + C], which incorrectly models magnetization as a function of charge rather than magnetic field.
  • Comparing the predicted hysteretic magnetization loops from the model with actual ferromagnetic/ferrimagnetic hysteresis curves, revealing a lack of true hysteresis.
  • Reproducing the voltage response using the derived equation V(t) = (μ₀SM_S/S_W)sech²(...)I(t) and showing it fails to match the experimental curves in the original paper.
  • Identifying inconsistencies in the 'negative memristor' emulator design, particularly missing connections and unexplained negative resistors.
  • Applying a gedanken experiment based on the charge recovery test for memristors, showing the Φ-memristor fails to return to its initial state after a full cycle.
  • Using a triangular voltage pulse to illustrate that magnetization reversal is irreversible under the model, violating the core condition of memristor behavior.

Experimental results

Research questions

  • RQ1Does the Φ-memristor model correctly describe the hysteretic magnetization dynamics of real magnetic materials?
  • RQ2Can the theoretical voltage response derived from the model reproduce the experimental curves presented in the original paper?
  • RQ3Does the Φ-memristor satisfy the recently proposed memristor test based on charge recovery and state return?
  • RQ4Is the 'negative memristor' emulator design technically sound and physically consistent?
  • RQ5What is the true electrical classification of a current-carrying wire through a magnetic core?

Key findings

  • The model's magnetization dynamics equation m(t) = tanh[q(t)/S_W + C] fails to capture the hysteretic behavior of real ferromagnetic and ferrimagnetic materials, as it never allows magnetization to drop below the initial value.
  • The predicted voltage response using V(t) = (μ₀SM_S/S_W)sech²(...)I(t) does not match the experimental curves in the original paper, particularly in the timing of voltage peaks.
  • The authors cannot reproduce Fig. 5 of the original paper using the analytical voltage equation, suggesting undocumented modifications or errors in the data presentation.
  • The 'negative memristor' emulator design is incomplete, lacking proper connections between measurement terminals and switching resistors, and the use of negative resistors without active components is physically unjustified.
  • The Φ-memristor fails the charge recovery test: after a triangular voltage pulse that fully discharges the capacitor, the device does not return to its initial resistance state due to irreversible magnetization switching.
  • The device is correctly classified as a meminductive system (inductor with memory), not a memristor, as previously established by the authors and Chua in prior work.